BLD01-01172
| FIRE-Final Inspection | 2/6/2002 | 2/8/2002 | 2/8/2002 12:00:00 AM | A | PART |
|
|
Fire life/safety and fire sprinkler finaled. Fire alarm given temp. occ. per Dave Miller. See FIR01-00551 for correction notice 2/8/2002 2:34:16 PM
|
FIR01-00293
| INSP-Sprinkler Rough-in/Hydro | 2/5/2002 | 2/8/2002 | 2/8/2002 12:00:00 AM | A | CANC |
|
|
duplicate inspection 2/8/2002 2:12:30 PM
|
FIR01-00586
| INSP-Sprinkler Rough-in/Hydro | 2/6/2002 | 2/8/2002 | 2/8/2002 12:00:00 AM | A | CANC |
|
|
cancelled by contractor 2/8/2002 12:43:04 PM
|
FIR01-00217
| INSP-Alarm Testing | 2/6/2002 | 2/8/2002 | 2/8/2002 12:00:00 AM | P | PASS |
|
|
fire alarm system finaled 2/8/2002 2:10:54 PM
|
BLD01-02660
| FIRE-Final Inspection | 2/8/2002 | 2/8/2002 | 2/8/2002 12:00:00 AM | P | PASS |
|
|
fire life/safety finaled 2/8/2002 4:46:37 PM
|
FIR02-00003
| INSP-Sprinkler Rough-in/Hydro | 2/8/2002 | 2/8/2002 | 2/8/2002 12:00:00 AM | P | PART |
|
|
reception hall OK for cover 2/8/2002 3:26:58 PM
|
BLD00-02283
| FIRE-Final Inspection | 2/8/2002 | 2/8/2002 | 2/8/2002 12:00:00 AM | P | PASS |
|
|
Added by Inspector: 430 On 2/8/2002 2:10:32 PM Fire life/safety finaled
|
BLD00-02281
| FIRE-Final Inspection | 2/8/2002 | 2/8/2002 | 2/8/2002 12:00:00 AM | P | PASS |
|
|
Added by Inspector: 430 On 2/8/2002 2:13:48 PM Fire life/safety finaled
|
BLD00-02281
| FIRE-Final Inspection | 2/8/2002 | 2/8/2002 | 2/8/2002 12:00:00 AM | P | PASS |
|
|
Added by Inspector: 430 On 2/8/2002 2:19:51 PM Fire life/safety finaled
|
BLD00-02282
| FIRE-Final Inspection | 2/8/2002 | 2/8/2002 | 2/8/2002 12:00:00 AM | P | PASS |
|
|
Added by Inspector: 430 On 2/8/2002 2:21:34 PM FIre life/safety finaled. fire sprinkler and fire alarm finaled
|
BLD00-03077
| FIRE-Final Inspection | 2/8/2002 | 2/8/2002 | 2/8/2002 12:00:00 AM | P | PASS |
|
|
Added by Inspector: 430 On 2/8/2002 2:27:42 PM Fire life/safety finaled
|
BLD00-03078
| FIRE-Final Inspection | 2/8/2002 | 2/8/2002 | 2/8/2002 12:00:00 AM | P | PASS |
|
|
Added by Inspector: 430 On 2/8/2002 2:28:23 PM Fire life/safety finaled
|
BLD00-03079
| FIRE-Final Inspection | 2/8/2002 | 2/8/2002 | 2/8/2002 12:00:00 AM | P | PASS |
|
|
Added by Inspector: 430 On 2/8/2002 2:28:57 PM Fire life/safety finaled
|
FIR01-00551
| INSP-Final Inspection | 2/8/2002 | 2/8/2002 | 2/8/2002 12:00:00 AM | P | PART |
|
|
Added by Inspector: 430 On 2/8/2002 2:32:57 PM Temp. occupancy given per Dave Miller. Contractor is allowed to let single station smoke detectors come in as system alarm for now, 2nd floor strobe circuits to be sync.ed and one strobe replaced.
|