ELE06-02976
| ELE-Request for Extension | 2/5/2007 | 2/6/2006 | | A | |
|
|
pls extend
|
ELE05-01605
| ELE-Aging Inspection | 2/8/2006 | 2/8/2006 | 2/10/2006 3:49:35 PM | | DONE |
|
|
see final
|
ELE05-01656
| ELE-Aging Inspection | 2/8/2006 | 2/8/2006 | 2/8/2006 4:10:18 PM | | DONE |
|
|
see final
|
ELE06-00456
| Electrical Rough-In | 2/8/2006 | 2/8/2006 | 2/8/2006 4:07:51 PM | P | PASS |
|
|
ufer ground for the shell building call Dana ###-#### to meet you. ok to pour gec
|
ELE05-04112
| Final | 2/8/2006 | 2/8/2006 | 2/8/2006 4:06:37 PM | P | FAIL |
|
|
dan; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa called contr, left corr notice, 680.73 electrical equipment for tub shall be accessible without damaging building, 406.5 recpt faceplate shall seat against mounting surface (upper bath), 406.4 recpts shall be securely fastened in place(front room, north side), 110.3(B) listed equipment shall be installed in accordance with instructions(mbr closet light lens)
|
ELE06-00455
| Electrical Rough-In | 2/8/2006 | 2/8/2006 | 2/8/2006 3:10:57 PM | P | PASS |
|
|
James; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong ric walls only ok
|
ELE06-00452
| Rough-In Permanent Service | 2/8/2006 | 2/8/2006 | 2/8/2006 1:41:54 PM | P | PASS |
|
|
Internet Inspection Request from: Rowdy Monroe called contr, left survey, 210.52(E) there shall be a recpt at front of dwelling, ric ok, p/s u/g n ok
|
ELE06-00381
| Temporary Service | 2/7/2006 | 2/8/2006 | 2/8/2006 10:31:02 AM | A | FAIL |
|
|
Phone #: ###-#### Internet Inspection Request from: Tina Payne met elect, left corr notice, 240.81 ckt breaker handle sjall be up in on position, 250.28(A) bonding jumper shall be done with green screw supplied, 110.3(B) equipment shall be installed with instructions included
|
ELE05-04648
| Permanent Service | 2/7/2006 | 2/8/2006 | 2/8/2006 9:28:47 AM | A | PASS |
|
|
please call 30 min prior to meet you//tracy; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa talked to owner, told to provide abrasion protection for gec in sub-panel, and add bond bushing to service panel, put cover on subpanel prior to energizng panel. Told owner to call for ri before cover. p/s o/h n ok
|
ELE06-00437
| Final | 2/7/2006 | 2/8/2006 | 2/8/2006 8:45:15 AM | A | PASS |
|
|
Please call John before going to set up time to meet, so that he can show the work. ###-####; Phone #: ###-#### Internet Inspection Request from: Dana Moyer met contr, ok to final
|
ELE06-00353
| Permanent Service | 2/7/2006 | 2/8/2006 | 2/8/2006 8:16:54 AM | A | PASS |
|
|
Please Call Bobby Langner ###-####; Phone #: ###-#### x39 Internet Inspection Request from: Kristopher wilson called contr, corrections made, ric walls and insulated ceiling ok, p/s, exst meter pak, n, ok
|
ELE05-01575
| Final | 2/8/2006 | 2/8/2006 | 2/8/2006 12:00:00 AM | P | PASS |
|
|
ok to final
|
ELE05-01656
| Final | 2/8/2006 | 2/8/2006 | 2/8/2006 12:00:00 AM | P | PASS |
|
|
ok to final
|