Inspections for the day of: Thursday, February 8, 2018.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorTom Saunders
TitleELE-INSPECTOR
Phone #208-794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE18-00516 Final2/8/20182/8/20182/8/2018 2:51:21 PMACANC
outlets added by homeowner...Brandon ###-####...scheduled wrong day
ELE18-00512 Final2/8/20182/8/20182/8/2018 2:46:09 PMPPASS
Phone #: ###-#### Inspection requested via web by Bryan McLaughlin...job complete...connected to existing floor outlet...ok to final
ELE18-00512 Electrical Rough-In2/8/20182/8/20182/8/2018 2:45:21 PMPPASS
Phone #: ###-#### Inspection requested via web by Bryan McLaughlin...kiosik wired with surface mounted material and steel boxes, outlets and lighting needed, and whip for power
ELE12-01568 ELE-Aging Inspection2/8/20182/8/20182/8/2018 2:41:04 PM FAIL
contractor has be notified multiple times...still needs to obtain access
ELE16-04036 Final2/7/20182/8/20182/8/2018 2:04:25 PMPPASS
Phone #: ###-#### Inspection requested via web by Jim Williams...job complete...ok to final
ELE18-00460 Temporary Service2/8/20182/8/20182/8/2018 1:14:24 PMPPASS
Temp pole is located on property line down driveway of the White House to the north of lot Phone #: ###-#### Inspection requested via web by Jay Hutchison..t/s u/g new ok
ELE18-00317 Conference2/7/20182/8/20182/8/2018 12:29:18 PMAPASS
Shawn Case is the contact. Review transformer location. Phone #: ###-#### Inspection requested via web by Kerri Hamilton...discussed location of transformer...clearances around it and panel in room
ELE18-00218 Electrical Rough-In2/6/20182/8/20182/8/2018 11:03:24 AMAPASS
Pls contact Brad (Foreman) @ ###-#### or Preston (Electrician) @ ###-#### one hr prior or if you have any questions. Thank you. Inspection requested via web by Rob Maes...UL listing verified...30A breaker in panel in basement and equipment back of house...access wiil be needed at final
ELE17-04191 Final2/7/20182/8/20182/8/2018 10:44:56 AMAFAIL
access key is on the North rock formation to the right of the doors on a red rock at eye level, call ###-#### Phone #: ###-#### Inspection requested via web by David Nelson..
1.outlet within 6' of sink shall have GFCI protectrion
2. OCPD on A/C is too large
3. A/C shall be labelled for identification
4. plates need installed on switch and outlets inside hearing booth...light covers installed
5. service outlet for A/Cs has no power..check GFCI protection
ELE16-03793 Final2/7/20182/8/20182/8/2018 10:09:26 AMAPASS
Bldg 200 final...all buildings completed associated to permit...ok to final
ELE18-00161 Permanent Service2/7/20182/8/20182/8/2018 8:45:17 AMACANC
We need underground inspection please. I chose permanent service inspection type, since there is no underground inspection option. Thank you. Phone #: ###-#### Inspection requested via web by Kyle Lott...needed rough underground
ELE18-00161 Electrical Rough-In2/8/20182/8/20182/8/2018 8:44:50 AMAPASS
We need underground inspection please. I chose permanent service inspection type, since there is no underground inspection option. Thank you. Phone #: ###-#### Inspection requested via web by Kyle Lott...underground feeds ok to cover