ELE03-03053
| Final | 2/6/2004 | 2/9/2004 | 2/9/2004 12:00:00 AM | A | PASS |
|
|
jean; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie ok 2/9/2004 8:04:52 AM
|
ELE04-00339
| Electrical Rough-In | 2/6/2004 | 2/9/2004 | 2/9/2004 12:00:00 AM | A | PART |
|
|
###-#### Dennis walls ok 2/9/2004 8:51:32 AM
|
ELE04-00311
| Permanent Service | 2/6/2004 | 2/9/2004 | 2/9/2004 12:00:00 AM | A | NR |
|
|
roll up door will be open, owner says okay to go in.; Phone #: ###-#### Internet Inspection Request from: Andy Rose not ready needs lights and switch for required lighting for panelboard also outdoor lights by exit doors called 2/9/2004 9:03:34 AM
|
ELE03-04011
| Final | 2/6/2004 | 2/9/2004 | 2/9/2004 12:00:00 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 2/6/2004 at 3:19:06 PM. Contact: ###-####. ok 2/9/2004 9:46:07 AM
|
ELE03-03969
| Final | 2/6/2004 | 2/9/2004 | 2/9/2004 12:00:00 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 2/6/2004 at 3:20:42 PM. ok 2/9/2004 10:05:37 AM
|
ELE03-03970
| Final | 2/6/2004 | 2/9/2004 | 2/9/2004 12:00:00 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 2/6/2004 at 3:21:49 PM. ok 2/9/2004 10:05:46 AM
|
ELE04-00265
| Permanent Service | 2/6/2004 | 2/9/2004 | 2/9/2004 12:00:00 AM | A | PASS |
|
|
lowell; Phone #: ###-#### Internet Inspection Request from: Annette Moore
p/s o/h rec. ok 2/9/2004 8:34:40 AM
|
ELE04-00347
| Electrical Rough-In | 2/9/2004 | 2/9/2004 | 2/9/2004 12:00:00 AM | P | PART |
|
|
Scheduled by a contractor via Hello! on 2/9/2004 at 8:03:43 AM. Contact: ###-####. print marked 1 wall 2/9/2004 3:09:03 PM
|
ELE04-00323
| Rough-In Permanent Service | 2/9/2004 | 2/9/2004 | 2/9/2004 12:00:00 AM | P | PASS |
|
|
We:1)ran two PVC conduits(with 1 circuit in each)in customer's trench(24" deep)from a new j-box on the trailer: 1 pvc to the existing well-head to by-pass the existing faulted circuit, and 1 pvc to the light pole near the gate for the new pole light.
3)ran EMT and IMC from the trailer to the panel inside the building for power.
Customer has back-filled the trench so they could drive across it.
Thanks !!!; Phone #: ###-#### Internet Inspection Request from: Dan Mitchell ok 2/9/2004 12:26:41 PM
|
ELE03-03735
| Final | 2/9/2004 | 2/9/2004 | 2/9/2004 12:00:00 AM | P | PART |
|
|
Scheduled by a contractor via Hello! on 2/9/2004 at 10:13:20 AM. Contact: ###-####. T. O. only contractor waiting for generator 2/9/2004 1:09:47 PM
|
ELE03-00815
| Rough-In Permanent Service | 2/9/2004 | 2/9/2004 | 2/9/2004 12:00:00 AM | P | FAIL |
|
|
dan; Phone #: ###-#### Internet Inspection Request from: Annette Moore all corrections not made, and new ones created 314.28 jbox back back of p/s 110.3(B) no metallic nipples allowed in plastic boxes, where is grd or bond to water system?, 11/2 flex at sub panel not in fitting and needs proper radius of bend COW called 2/9/2004 2:00:25 PM
|