Inspections for the day of: Monday, February 9, 2004.
Number of inspections: 11
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE03-03053 Final2/6/20042/9/20042/9/2004 12:00:00 AMAPASS
jean; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie ok 2/9/2004 8:04:52 AM
ELE04-00339 Electrical Rough-In2/6/20042/9/20042/9/2004 12:00:00 AMAPART
###-#### Dennis walls ok 2/9/2004 8:51:32 AM
ELE04-00311 Permanent Service2/6/20042/9/20042/9/2004 12:00:00 AMANR
roll up door will be open, owner says okay to go in.; Phone #: ###-#### Internet Inspection Request from: Andy Rose not ready needs lights and switch for required lighting for panelboard also outdoor lights by exit doors called 2/9/2004 9:03:34 AM
ELE03-04011 Final2/6/20042/9/20042/9/2004 12:00:00 AMAPASS
Scheduled by a contractor via Hello! on 2/6/2004 at 3:19:06 PM. Contact: ###-####. ok 2/9/2004 9:46:07 AM
ELE03-03969 Final2/6/20042/9/20042/9/2004 12:00:00 AMAPASS
Scheduled by a contractor via Hello! on 2/6/2004 at 3:20:42 PM. ok 2/9/2004 10:05:37 AM
ELE03-03970 Final2/6/20042/9/20042/9/2004 12:00:00 AMAPASS
Scheduled by a contractor via Hello! on 2/6/2004 at 3:21:49 PM. ok 2/9/2004 10:05:46 AM
ELE04-00265 Permanent Service2/6/20042/9/20042/9/2004 12:00:00 AMAPASS
lowell; Phone #: ###-#### Internet Inspection Request from: Annette Moore
p/s o/h rec. ok 2/9/2004 8:34:40 AM
ELE04-00347 Electrical Rough-In2/9/20042/9/20042/9/2004 12:00:00 AMPPART
Scheduled by a contractor via Hello! on 2/9/2004 at 8:03:43 AM. Contact: ###-####. print marked 1 wall 2/9/2004 3:09:03 PM
ELE04-00323 Rough-In Permanent Service2/9/20042/9/20042/9/2004 12:00:00 AMPPASS
We:1)ran two PVC conduits(with 1 circuit in each)in customer's trench(24" deep)from a new j-box on the trailer: 1 pvc to the existing well-head to by-pass the existing faulted circuit, and 1 pvc to the light pole near the gate for the new pole light.
3)ran EMT and IMC from the trailer to the panel inside the building for power.
Customer has back-filled the trench so they could drive across it.
Thanks !!!; Phone #: ###-#### Internet Inspection Request from: Dan Mitchell ok 2/9/2004 12:26:41 PM
ELE03-03735 Final2/9/20042/9/20042/9/2004 12:00:00 AMPPART
Scheduled by a contractor via Hello! on 2/9/2004 at 10:13:20 AM. Contact: ###-####. T. O. only contractor waiting for generator 2/9/2004 1:09:47 PM
ELE03-00815 Rough-In Permanent Service2/9/20042/9/20042/9/2004 12:00:00 AMPFAIL
dan; Phone #: ###-#### Internet Inspection Request from: Annette Moore all corrections not made, and new ones created 314.28 jbox back back of p/s 110.3(B) no metallic nipples allowed in plastic boxes, where is grd or bond to water system?, 11/2 flex at sub panel not in fitting and needs proper radius of bend COW called 2/9/2004 2:00:25 PM