Inspections for the day of: Wednesday, February 9, 2005.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE04-03651 Final2/8/20052/9/20052/9/2005 12:00:00 AMAPASS
Scheduled by a contractor via Hello! on 2/8/2005 at 8:19:20 AM. Contact: ###-####. ok card signed 2/9/2005 11:51:48 AM
ELE05-00333 Electrical Rough-In2/8/20052/9/20052/9/2005 12:00:00 AMAPART
richard ###-#### ok see added p/s 2/9/2005 9:16:33 AM
ELE05-00424 Temporary Service2/8/20052/9/20052/9/2005 12:00:00 AMAPASS
al ###-#### ok t/s u/g new 2/9/2005 9:53:42 AM
ELE05-00389 Rough-In Permanent Service2/8/20052/9/20052/9/2005 12:00:00 AMAFAIL
Please inspect and call me for any questions thanks; Phone #: ###-#### Internet Inspection Request from: William Zerfas cor. and fee due posted called 210.52(A)&(B) needs outlet in liv rm and upstairs bed rm, and complete wiring in island counter 2/9/2005 9:29:14 AM
ELE05-00068 Rough-In Permanent Service2/8/20052/9/20052/9/2005 12:00:00 AMAPASS
Scheduled by a contractor via Hello! on 2/8/2005 at 8:02:52 PM. Contact: ###-####. u/g ok p/s u/g new ok 2/9/2005 8:24:10 AM
ELE05-00333 Permanent Service2/9/20052/9/20052/9/2005 12:00:00 AMAPASS
p/s u/g new ok
ELE05-00379 Electrical Rough-In2/9/20052/9/20052/9/2005 12:00:00 AMPPART
Sorry for the mix up, call if you need. Thank you very much. Haley; Phone #: ###-#### Internet Inspection Request from: BRIAN KEITH ok 2/9/2005 3:19:13 PM
ELE05-00193 Final2/9/20052/9/20052/9/2005 12:00:00 AMPPASS
brian; Phone #: ###-#### Internet Inspection Request from: Barbara Moore ok 2/9/2005 2:01:29 PM
ELE05-00391 Electrical Rough-In2/9/20052/9/20052/9/2005 12:00:00 AMPPASS
r/i for garage ok
ELE04-04111 Electrical Rough-In2/9/20052/9/20052/9/2005 12:00:00 AMPPASS
Scheduled by a contractor via Hello! on 2/9/2005 at 7:10:28 AM. Contact: ###-####. ceiling ok 2/9/2005 1:18:50 PM
ELE05-00307 Electrical Rough-In2/9/20052/9/20052/9/2005 12:00:00 AMPFAIL

or ###-####5 tony; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
partail cor. posted job not ready box fill staple cables at boxes nail plates 11/4 ", free length of conductor , no screws in plastic boxes grd metal boxes replace boxes with broken clamps, shall not split wire to fit under lug, complete all make up use #12 equip grd wire for 20 amp circuits not 14 have all wiring ready,, all walls built,, C O W 2/9/2005 3:45:22 PM
ELE05-00391 Permanent Service2/9/20052/9/20052/9/2005 12:00:00 AMPNR
Lars; Phone #: ###-#### Internet Inspection Request from: Jan Rice needs GEC termianted at 1st 5 ft of u/g water pipe front NW bed rm downstairs see added r/i 2/9/2005 12:28:33 PM
ELE04-03977 Rough-In Permanent Service2/8/20052/9/20052/8/2005 6:35:42 PMACANC
Please contact me for any questions; Phone #: ###-#### Internet Inspection Request from: William Zerfas Inspection cancelled from web by: William Zerfas