MEC07-00686
| Rough-in | 3/1/2007 | 3/1/2007 | 3/1/2007 4:42:32 PM | P | FAIL |
|
|
Phone #: ###-#### condensate drain cannot be direct connected to building drain, support flex duct every 5', ok to cover will check items at final
|
MEC07-00666
| Final | 3/1/2007 | 3/1/2007 | 3/1/2007 4:05:47 PM | P | PASS |
|
|
Phone #: ###-#### x4254
|
MEC07-00496
| Pressure Test | 3/1/2007 | 3/1/2007 | 3/1/2007 3:35:39 PM | P | PASS |
|
|
Please call Darrin if you have any questions. Phone #: ###-#### already passed gas test 2 lines with 60# test
|
MEC07-00687
| Pressure Test | 3/1/2007 | 3/1/2007 | 3/1/2007 3:34:59 PM | P | FAIL |
|
|
Please call Darrin if you have any questions! Phone #: ###-####
|
MEC07-00687
| Rough-in | 3/1/2007 | 3/1/2007 | 3/1/2007 3:34:43 PM | P | FAIL |
|
|
Please call Karl if you have any questions! Phone #: ###-#### left c/n
|
MEC07-00685
| Pressure Test | 3/1/2007 | 3/1/2007 | 3/1/2007 2:11:09 PM | P | PASS |
|
|
Relocation of gas line from meter to furnace. Please inspect as close to 2:00p.m. as possible. We would like to be able to fire furnace back up for occupants. Phone #: ###-####
|
MEC07-00632
| Final | 3/1/2007 | 3/1/2007 | 3/1/2007 1:27:45 PM | P | PASS |
|
|
dedra - re-inspection ; Phone #: ###-#### x 201 Internet Inspection Request from: Patricia Smith
|
MEC07-00672
| Final | 2/28/2007 | 3/1/2007 | 3/1/2007 12:16:52 PM | A | PASS |
|
|
Tool Hook-Up Phone #: ###-####
|
MEC06-01889
| Final | 3/1/2007 | 3/1/2007 | 3/1/2007 11:51:30 AM | A | PASS |
|
|
gas connections to ovens ok
|
MEC06-01880
| Final | 2/28/2007 | 3/1/2007 | 3/1/2007 11:49:02 AM | A | PASS |
|
|
Dave; Phone #: ###-#### Internet Inspection Request from: Stacie Backus
|
MEC06-04287
| Final | 2/28/2007 | 3/1/2007 | 3/1/2007 11:22:24 AM | A | PASS |
|
|
Sammy was installer if you have any questions. His # is ###-####. Thank you!! Phone #: ###-####
|
MEC07-00678
| Rough-in | 2/28/2007 | 3/1/2007 | 3/1/2007 10:31:21 AM | A | PASS |
|
|
Dick; Phone #: ###-#### Internet Inspection Request from: Stacie Backus
|
MEC07-00632
| Final | 2/23/2007 | 3/1/2007 | 3/1/2007 9:59:45 AM | A | FAIL |
|
|
please call melanie with any questions- unit is in a storage space directly outside front door- access is available, space is vacant Phone #: ###-#### flex connector in furnace housing, air intake to extend out of furnacing housing with 90 degree fitting, 45 degree fitting at flue termination needs to be turned down
|
MEC07-00673
| Rough-in | 2/28/2007 | 3/1/2007 | 3/1/2007 9:36:45 AM | A | FAIL |
|
|
Marilyn; Phone #: ###-#### Internet Inspection Request from: Stacie Backus need platform from attic access to furnace platform
|
MEC07-00674
| Rough-in | 2/28/2007 | 3/1/2007 | 3/1/2007 9:16:28 AM | A | PASS |
|
|
Marilyn; Phone #: ###-#### Internet Inspection Request from: Stacie Backus 20# test
|