Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE10-00246 Rough-In Permanent Service3/1/20103/1/20103/1/2010 3:57:23 PMPCANC
Inspection requested from web by: TOM BICANDI Phone #: ###-#### see ri and p/s
ELE10-00246 Electrical Rough-In3/1/20103/1/20103/1/2010 3:56:53 PMPFAIL
Inspection requested from web by: TOM BICANDI Phone #: ###-#### called left correction notice, NEC 300.4(A)(1) edge of bored holes shall be 1 1/4" from edge of framing members, 314.17 conductors entering boxes shall be protected from abrasion-garage lights, 314.14 shall not exceed box fill for garage lights, NOTE: corrections shall be made within 5 working days or further action will be taken
ELE10-00246 Permanent Service3/1/20103/1/20103/1/2010 3:52:17 PMPPASS
Inspection requested from web by: TOM BICANDI Phone #: ###-#### p/s u/g n ok
ELE10-00185 Final3/1/20103/1/20103/1/2010 3:51:04 PMPFAIL
mike Phone #: ###-#### met contractor, correction notice,BCC4-05-33(A)(B) mixer and icemaker shall be listed by a nationally recognized testing laboratory, NEC 210.63 shall provide showroom receptacles, corrections shall be made within 5 working days or further action will be taken
ELE10-00386 Conference3/1/20103/1/20103/1/2010 3:37:31 PMPDONE
Steve Phone #: ###-#### talked about service and grounding, no esc this project
ELE10-00395 Electrical Rough-In3/1/20103/1/20103/1/2010 2:49:18 PMPPASS
Inspection requested from, web by: BARRY KENDALL Phone #: ###-#### corrections made, ri ok, no esc
ELE10-00395 Final3/1/20103/1/20103/1/2010 2:49:01 PMPPASS
Inspection requested from web by: BARRY KENDALL Phone #: ###-#### ok to final, no esc, signed card
ELE09-00026 Final3/1/20103/1/20103/1/2010 2:43:50 PMPPASS
Please call 30 minutes before so I can meet you there. Thanks Inspection requested from web by: Thomas Marshall Phone #: ###-#### ok to final, no esc this project
ELE10-00195 Final3/1/20103/1/20103/1/2010 2:40:39 PMPFAIL
corey Phone #: ###-#### ok to final, no esc this project called, left correction notice, BCC 4-05-33(A)(B) all equipment shall be listed by a nationally recognized testing laboratory, NOTE corrections shall be made within 10 working days or further action will be taken
ELE10-00330 Rough-In Permanent Service2/26/20103/1/20103/1/2010 10:29:39 AMAPASS
thank you!! Inspection requested from web by: Tracy Robertson Phone #: ###-#### ric ok, p/s u/g n ok
ELE10-00280 Final2/26/20103/1/20103/1/2010 10:01:43 AMAFAIL
Wayne Phone #: ###-#### met contractor, left correction notice, NEC 400.8(1) flexible cord shall not be used as a substitute for fixed wiring of structure, 410.62(C) shall permit cord connected if meetrs part (C)(1), NOTE corrections shall be made within 5 working days or further action will be taken, no esc this project
ELE10-00395 Final2/27/20103/1/20103/1/2010 9:15:38 AMAFAIL
Inspection requested from web by: BARRY KENDALL Phone #: ###-#### met contractor, left correction notice, NEC 110.12(A) shall close unused openings in box, 210.8(B)(2) all 125v receptacles in kitchen shall be gfci, 330.30(B) shall strap mc within 12" of box, 358.30(A) shall strap emt within 3' of box, 248.30(A) fmc shall be strapped within 12" of box, 300.15 shall provide box at termination of cable, BCC no violations shall be retained, NOTE- corrections shall be made within 5 working days or further action will be taken, NOTE: contractor shall call for ri for re-inspection, no esc this project
ELE10-00246 Rough-In Permanent Service3/1/20103/1/20103/1/2010 8:39:31 AMANR
Inspection requested from web by: TOM BICANDI Phone #: ###-#### saw electrician, not done, see fee due