ELE12-02370
| ELE-Aging Inspection | 3/1/2016 | 3/1/2016 | 3/3/2016 3:45:55 PM | | PASS |
|
|
Waiting on contractor
|
GCE15-00156
| GCE-Final | 3/1/2016 | 3/1/2016 | 3/1/2016 2:40:06 PM | P | FAIL |
|
|
###-#### - code: 2727 110.3(B)- Device shall be connected as to its instructions. Bath receptacle miss wire. 110.3(B)- Device shall be connected as to its instructions. Back patio receptacle not working. 422.31(B)- Microwave shall have an accessible disconnecting means.110.25 lockout acceptable.
|
GCE15-00157
| GCE-Final | 3/1/2016 | 3/1/2016 | 3/1/2016 2:31:29 PM | P | FAIL |
|
|
###-#### - code: 2727 210.12- All 15 or 20 amp 120 volt outlets located in a bedroom shall have AFCI protection. 210.52(3)- Receptacles required be 210.52 shall be in addition to those located in cabinets. Master bed receptacle with 6' of door south wall. 210.70(A)(1)- At least 1 outlet controlled by wall switch shall be located in habitable rooms. Family room. 422.31(B)- Microwave shall have an accessible disconnecting means. 110.25- lockout acceptable.
|
GCE15-00158
| GCE-Final | 3/1/2016 | 3/1/2016 | 3/1/2016 2:25:55 PM | A | FAIL |
|
|
###-#### - code: 2727 408.4- 20 and 25 amp 2-pole breakers shall be identified as to its purpose. check spare breakers. 410.16(B)- Luminaires located in a closet shall have totally enclosed lamps. 422.31(B)- Microwave shall have an accessible disconnecting means. 110.25- lockout acceptable.
|
ELE16-00552
| Electrical Rough-In | 3/1/2016 | 3/1/2016 | 3/1/2016 12:56:46 PM | P | CANC |
|
|
Please call Matt when you are on your way ###-####. Thank You. Phone #: ###-#### Inspection requested via web by Clay Morgan Dupicate request see AM Rough in
|
ELE97-02803
| Final | 2/29/2016 | 3/1/2016 | 3/1/2016 12:04:47 PM | A | PASS |
|
|
would like call 30min ahead; Scott Phone #: ###-#### All that were accessible checked ok. Final ok
|
ELE16-00610
| Final | 2/29/2016 | 3/1/2016 | 3/1/2016 11:14:11 AM | A | PASS |
|
|
The work area is located on the exterior southeast corner of the truss plant. All for Gary or Abel. If you have questions please call Jeremiah at ###-####, thank you! Phone #: ###-#### Inspection requested via web by Dan Mitchell Final ok
|
ELE16-00610
| Electrical Rough-In | 2/29/2016 | 3/1/2016 | 3/1/2016 11:09:50 AM | A | PASS |
|
|
The work area is located on the exterior southeast corner of the truss plant. All for Gary or Abel. If you have questions please call Jeremiah at ###-####, thank you! Phone #: ###-#### Inspection requested via web by Dan Mitchell Rough in ok
|
ELE16-00510
| Final | 2/29/2016 | 3/1/2016 | 3/1/2016 10:34:04 AM | A | PASS |
|
|
Chad VanOrden is contact at ###-####. thank you. Phone #: ###-#### Inspection requested via web by Debby Pierce Final ok
|
ELE16-00552
| Electrical Rough-In | 2/29/2016 | 3/1/2016 | 3/1/2016 10:06:07 AM | A | PASS |
|
|
Please call Matt ###-#### when you are on your way. Thank You!!!! Phone #: ###-#### Inspection requested via web by Clay Morgan Kitchen remodel. Sink wall not changed other areas counter receptacles added for changes in cab layout. Rough in ok cover
|
ELE16-00614
| Temporary Service | 2/29/2016 | 3/1/2016 | 3/1/2016 9:18:44 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by TOM BICANDI t/s u/g n ok
|
ELE16-00615
| Temporary Service | 2/29/2016 | 3/1/2016 | 3/1/2016 9:18:14 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by TOM BICANDI t/s u/g n ok
|
ELE16-00552
| Rough-In Permanent Service | 2/29/2016 | 3/1/2016 | 2/29/2016 5:07:38 PM | A | CANC |
|
|
Please call Matt ###-#### when you are on your way. Thank You!!! Phone #: ###-#### >> Inspection requested via web by Clay Morgan Inspection cancelled from web by: Clay Morgan
|