Inspections for the day of: Tuesday, March 1, 2016.
Number of inspections: 18
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorChad Schwendiman
TitleMEC-INSPECTOR
Phone #780-9549
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC16-00610 Pressure Test3/1/20163/1/20163/1/2016 4:06:30 PMPPASS
Phone #: ###-#### Inspection requested via web by Troy Worley - 20lb gas pass
MEC16-00610 Rough-in3/1/20163/1/20163/1/2016 4:06:01 PMPPASS
Phone #: ###-#### Inspection requested via web by Troy Worley
MEC16-00902 Pressure Test3/1/20163/1/20163/1/2016 3:07:58 PMPPASS
Please call Daryl with any questions. Phone #: ###-#### Inspection requested via web by Diane Day - 20lb gas pass
MEC16-00902 Rough-in3/1/20163/1/20163/1/2016 3:07:09 PMPPASS
Please call Daryl with any questions. Phone #: ###-#### Inspection requested via web by Diane Day
MEC16-00805 Pressure Test2/29/20163/1/20163/1/2016 2:26:43 PMPPASS
Please inspect after 2:00. Jill is the customer. ###-####. Thank you Phone #: ###-#### Inspection requested via web by Dustin Rich - 20lb gas pass
MEC16-00900 Final3/1/20163/1/20163/1/2016 2:15:46 PMPNR
Installer: Sam ###-####
Please Call with any questions.

Thank you Phone #: ###-#### Inspection requested via web by Dustin Rich
MEC16-00589 Pressure Test2/26/20163/1/20163/1/2016 1:41:44 PMPFAIL
Please call Daryl with any questions Phone #: ###-#### Inspection requested via web by Diane Day - 20lb gas fail, 60lb gas fail, 5lb flue fail
MEC16-00589 Rough-in2/26/20163/1/20163/1/2016 1:40:31 PMPFAIL
Please call Daryl with any questions Phone #: ###-#### Inspection requested via web by Diane Day
1) Crawl not complete
2) Need ladder to access furnace in attic
3) need to relocate fresh air and condensate that penetrate the exterior soffit, not allowed to penetrate the exterior soffit in a wui zone
4) Exhaust fan not vented on main level
5) Need make up air for range vent
MEC15-02759 Rough-in2/29/20163/1/20163/1/2016 10:26:02 AMAPART
Grease duct insulation. On site contact: Pat Nichols. Phone #: ###-#### Inspection requested via web by Melissa Kaae - 1st layer fire wrap okay on 9th floor both shafts
MEC16-00746 Rough-in2/29/20163/1/20163/1/2016 10:25:03 AMAPASS
Steve/###-####/fire wrap 1st layer. Phone #: ###-#### Inspection requested via web by Crystal Grant - 1st layer fire wrap pass
MEC15-01059 Mec-Aging Inspection3/1/20163/1/20163/1/2016 9:26:33 AM CANC
MEC16-00891 Conference2/29/20163/1/20163/1/2016 8:47:09 AMADONE
Call Lavaro to meet on-site ###-####
Jason ###-####
Inspection requested via web by Jason Robinson - meet with builder to discuss finishes around fireplace.
MEC16-00891 Rough-in2/29/20163/1/20163/1/2016 8:45:35 AMAFAIL
Clint ###-#### Phone #: ###-#### Inspection requested via web by Jason Robinson - need clearance to combustables per manufactures specs.
MEC15-01061 Mec-Aging Inspection3/1/20163/1/20163/1/2016 6:51:52 AM CANC
MEC15-01040 Mec-Aging Inspection3/1/20163/1/20163/1/2016 6:51:22 AM CANC
MEC15-03190 Mec-Aging Inspection3/1/20163/1/20163/1/2016 6:50:13 AM CANC
MEC16-00822 Pressure Test2/29/20163/1/20162/29/2016 2:57:24 PMACANC
Rough In and Pressure Test
Shaun: ###-#### Phone #: ###-#### >> Inspection requested via web by Frank Marturello Inspection cancelled from web by: Frank Marturello
MEC16-00822 Rough-in2/29/20163/1/20162/29/2016 2:57:22 PMACANC
Rough In and Pressure Test
Shaun: ###-#### Phone #: ###-#### >> Inspection requested via web by Frank Marturello Inspection cancelled from web by: Frank Marturello