Inspections for the day of: Thursday, March 1, 2018.
Number of inspections: 9
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE16-02746 Electrical Rough-In3/1/20183/1/20183/1/2018 3:05:08 PMPPASS
4th floor Lobby fur down rough cover
3rd floor Lobby fur down rough cover Phone #: ###-#### Inspection requested via web by Kenneth Chapman
Areas noted rough in ok cover
ELE17-04231 Final3/1/20183/1/20183/1/2018 2:50:07 PMPFAIL
garage code 7591 Phone #: ###-#### Inspection requested via web by kevin blackmon
110.7 Wiring Integrity. Completed wiring installations shall be free from short circuits, ground faults, or any connections to ground other than as required or permitted elsewhere in this Code.
Basement AFCI breaker will not hold. Trips when loan introduced.
ELE18-00711 Rough-In Permanent Service2/28/20183/1/20183/1/2018 2:22:53 PMPPASS
Phone #: ###-#### Inspection requested via web by Darryn Coburn
Rough in ok cover p/s u/g n ok
ELE18-00012 Final3/1/20183/1/20183/1/2018 1:48:52 PMPPASS
Garage code 1001E Phone #: ###-#### Inspection requested via web by Alan Lusk Final ok
ELE17-03991 Final2/28/20183/1/20183/1/2018 12:59:38 PMPFAIL
garage code 1234 Phone #: ###-#### Inspection requested via web by Jay Hutchison
110.3- 1 Garage receptacle and outdoor receptacle not working.
210.8- GFCI devices shall be located in a readily accessible location. Patio
210.52(D)- Up green bath shall have a receptacle outlet located adjacent to each basin.
314.23- Box to right of fireplace shall be securely mounted.
314.25- box to right of fireplace shall have a cover installed.
406.12- Outdoor GFCI devices shall be tamper resistant type.
ELE18-00237 Final2/28/20183/1/20183/1/2018 12:51:17 PMPFAIL
garage code 1234 Phone #: ###-#### Inspection requested via web by Jay Hutchison
Out door lights not working. on detached garage.
ELE18-00776 Electrical Rough-In2/28/20183/1/20183/1/2018 10:22:53 AMAPASS
Contact Steve Nuxoll with any questions

Thank you and have a nice day! Phone #: ###-#### Inspection requested via web by JENNY EMEL
5 receptacles in each conference room minimum.
Baths and shower rooms not ready, Rest of walls rough in ok cover.
ELE18-00763 Rough-In Permanent Service2/28/20183/1/20183/1/2018 9:46:13 AMAPASS
Phone #: ###-#### Inspection requested via web by John VanZandt
Class 2 used for pull wire, no changes to each side of fire place, receptacles in pantry are GFCI devices for wire mold.
Rough in ok cover p/s u/g n ok
ELE17-04027 Final2/28/20183/1/20183/1/2018 9:09:04 AMAPASS
Correction have been made as noted Phone #: ###-#### Inspection requested via web by Steve Craig
Final ok