ELE16-02746
| Electrical Rough-In | 3/1/2018 | 3/1/2018 | 3/1/2018 3:05:08 PM | P | PASS |
|
|
4th floor Lobby fur down rough cover 3rd floor Lobby fur down rough cover Phone #: ###-#### Inspection requested via web by Kenneth Chapman Areas noted rough in ok cover
|
ELE17-04231
| Final | 3/1/2018 | 3/1/2018 | 3/1/2018 2:50:07 PM | P | FAIL |
|
|
garage code 7591 Phone #: ###-#### Inspection requested via web by kevin blackmon 110.7 Wiring Integrity. Completed wiring installations shall be free from short circuits, ground faults, or any connections to ground other than as required or permitted elsewhere in this Code. Basement AFCI breaker will not hold. Trips when loan introduced.
|
ELE18-00711
| Rough-In Permanent Service | 2/28/2018 | 3/1/2018 | 3/1/2018 2:22:53 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Darryn Coburn Rough in ok cover p/s u/g n ok
|
ELE18-00012
| Final | 3/1/2018 | 3/1/2018 | 3/1/2018 1:48:52 PM | P | PASS |
|
|
Garage code 1001E Phone #: ###-#### Inspection requested via web by Alan Lusk Final ok
|
ELE17-03991
| Final | 2/28/2018 | 3/1/2018 | 3/1/2018 12:59:38 PM | P | FAIL |
|
|
garage code 1234 Phone #: ###-#### Inspection requested via web by Jay Hutchison 110.3- 1 Garage receptacle and outdoor receptacle not working. 210.8- GFCI devices shall be located in a readily accessible location. Patio 210.52(D)- Up green bath shall have a receptacle outlet located adjacent to each basin. 314.23- Box to right of fireplace shall be securely mounted. 314.25- box to right of fireplace shall have a cover installed. 406.12- Outdoor GFCI devices shall be tamper resistant type.
|
ELE18-00237
| Final | 2/28/2018 | 3/1/2018 | 3/1/2018 12:51:17 PM | P | FAIL |
|
|
garage code 1234 Phone #: ###-#### Inspection requested via web by Jay Hutchison Out door lights not working. on detached garage.
|
ELE18-00776
| Electrical Rough-In | 2/28/2018 | 3/1/2018 | 3/1/2018 10:22:53 AM | A | PASS |
|
|
Contact Steve Nuxoll with any questions
Thank you and have a nice day! Phone #: ###-#### Inspection requested via web by JENNY EMEL 5 receptacles in each conference room minimum. Baths and shower rooms not ready, Rest of walls rough in ok cover.
|
ELE18-00763
| Rough-In Permanent Service | 2/28/2018 | 3/1/2018 | 3/1/2018 9:46:13 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by John VanZandt Class 2 used for pull wire, no changes to each side of fire place, receptacles in pantry are GFCI devices for wire mold. Rough in ok cover p/s u/g n ok
|
ELE17-04027
| Final | 2/28/2018 | 3/1/2018 | 3/1/2018 9:09:04 AM | A | PASS |
|
|
Correction have been made as noted Phone #: ###-#### Inspection requested via web by Steve Craig Final ok
|