Inspections for the day of: Thursday, March 1, 2018.
Number of inspections: 22
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorDan Ediger
TitlePLM-INSPECTOR
Phone #869-5166
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM18-00859 Plumbing Rough-in3/1/20183/1/20183/1/2018 4:15:12 PMPFAIL
Phone #: ###-#### Inspection requested via web by Aarin Van Curen.
Hang all dwv at 48" max. ok to pull tests
PLM18-00816 Final2/28/20183/1/20183/1/2018 3:56:48 PMPPASS
Please inspect as late as possible and call Kyle Criddle about 30 minutes prior to inspection at ###-#### so he can get home. Phone #: ###-#### Inspection requested via web by Mary LaFayette
PLM17-03699 Final2/28/20183/1/20183/1/2018 3:23:55 PMPFAIL
Phone #: ###-#### Inspection requested via web by Dan McFate.
1. The condensate drain must be run or pumped to an approved drain. Will freeze outside.
2. You cannont use flex connectors to pipe to the water heater. Only one 24" max. to connect heater on each side.
3. Provide a bug screen on the air inlet.
4. The flue must be panited per code.
PLM17-04181 Plumbing Rough-in3/1/20183/1/20183/1/2018 2:52:24 PMPFAIL
Phone #: ###-#### Inspection requested via web by Brian Johansen.
Install plate straps on the 3" and nail plate where missing.
PLM17-04182 Plumbing Rough-in3/1/20183/1/20183/1/2018 2:51:43 PMPPASS
Phone #: ###-#### Inspection requested via web by Brian Johansen
PLM18-00548 Final3/1/20183/1/20183/1/2018 2:51:18 PMPPASS
MARK IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER.
Was unable to witness work. Per Mark the hubdrain was moved 1-ft.
PLM17-01661 Final2/28/20183/1/20183/1/2018 11:43:17 AMAFAIL
ZONA HEALTH INC IS THE TENANT IN THAT SUITE. THEY ARE IN THE OFFICE MONDAY - FRIDAY FROM 9AM UNTIL 5PM. THEY ARE AWARE THAT AN INSPECTION IS BEING
SCHEDULED. Phone #: ###-#### Inspection requested via web by Ben Davis
The rp backflow must be certified
PLM17-00217 Final3/1/20183/1/20183/1/2018 11:31:25 AMAFAIL
Drain the t&p drain with grade or drill a hole at the low point.
Install screws in the flue.
PLM18-00781 Other2/28/20183/1/20183/1/2018 11:06:53 AMAPASS
Inspection of repipe, To cover Pat Phone #: ###-#### Inspection requested via web by pat batten.
Repipe water and install tub.
PLM18-00191 Groundwork2/28/20183/1/20183/1/2018 10:33:26 AMAFAIL
HENRY IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER.
Seperate the grease waste per plans. Verify the main drain isn't installed on the grease trap inlet.
PLM18-00842 Water and/or Sewer2/28/20183/1/20183/1/2018 9:32:44 AMACANC
Juan Phone #: ###-####. Clened as ground work
PLM18-00842 Groundwork3/1/20183/1/20183/1/2018 9:32:22 AMAPART
Juan Phone #: ###-####.
Ground work for rr ok to cover. Excludes grease trap and grate drain system.
PLM17-00217 Final2/28/20183/1/20183/1/2018 9:15:06 AMANH
CALL SALLY (TENANT) WHEN AT THE DOOR. NUMBER IS ###-####. Phone #: ###-#### Inspection requested via web by Ben Davis
No answer. Please recall and leave unit number.
PLM17-02575 PLM-Aging Inspection3/1/20183/1/20183/1/2018 9:00:20 AM CANC
contractor to follow up
PLM17-02629 PLM-Aging Inspection3/1/20183/1/20183/1/2018 8:55:29 AM PASS
PLM17-02629 DOC - Permit Finaled3/1/20183/1/20183/1/2018 8:55:18 AMPPASS
called in as s/w should have been final
PLM15-00980 PLM-Aging Inspection3/1/20183/1/20183/1/2018 8:54:33 AM PASS
PLM15-00980 DOC - Permit Expired3/1/20183/1/20183/1/2018 8:54:21 AMPPASS
No action
PLM17-02624 PLM-Aging Inspection3/1/20183/1/20183/1/2018 8:50:15 AM PASS
PLM17-02624 DOC - Permit Finaled3/1/20183/1/20183/1/2018 8:50:03 AMPPASS
PLM17-04672 Plumbing Rough-in2/28/20183/1/20183/1/2018 8:49:33 AMAPASS
Ken Phone #: ###-####
Solar panal loop pressure test ok 100psi
PLM17-05070 Water and/or Sewer2/28/20183/1/20182/28/2018 2:58:32 PMAPASS
Phone #: ###-#### Inspection requested via web by Darren Wood