Inspections for the day of: Friday, March 10, 2006.
Number of inspections: 17
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorPat Lass
TitleELE-INSPECTOR
Phone #794-9478
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE05-04451 ELE-Aging Inspection3/10/20063/10/20063/17/2006 2:47:27 PM PASS
ELE05-04379 ELE-Aging Inspection3/10/20063/10/20063/15/2006 8:49:51 AM NR
suc
ELE05-04489 ELE-Aging Inspection3/10/20063/10/20063/15/2006 8:35:58 AM PASS
ELE06-00722 Electrical Rough-In3/10/20063/10/20063/10/2006 4:08:44 PMPPART
Renee; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong
anop
ELE06-00805 Permanent Service3/8/20063/10/20063/10/2006 4:08:24 PMPPART
need inspection on ufer ground plus new 200 amp overhead service Internet Inspection Request from: Andy Rose
electrode ok for concrete
ELE05-02097 Final3/10/20063/10/20063/10/2006 4:07:45 PMPNR
As late in the day as possible please; Phone #: ###-#### Internet Inspection Request from: Gary Gettman
electrician not finished and no clearance in front of main disconnect
ELE05-04515 Electrical Rough-In3/10/20063/10/20063/10/2006 2:59:31 PMPPASS
tom johnson -###-####
floor heat ok
ELE06-00827 Final3/10/20063/10/20063/10/2006 2:59:07 PMPNH
Phone #: ###-#### Internet Inspection Request from: Dana Moyer
no access called contractor and he will provide access and reschedual.
ELE06-00830 Rough-In Permanent Service3/10/20063/10/20063/10/2006 2:08:36 PMPPASS
Terry; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong
R/I Ok
P/S O/H R Ok
ELE06-00231 Permanent Service3/10/20063/10/20063/10/2006 1:05:21 PMPFAIL
Dennis; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong
250.104 Bonding of Piping Systems and Exposed Structural Steel.
(A) Metal Water Piping. The metal water piping system shall be bonded as required in (1), (2), (3), or (4) of this section.

250.119 Identification of Equipment Grounding Conductors.
Unless required elsewhere in this Code, equipment grounding conductors shall be permitted to be bare, covered, or insulated. Individually covered or insulated equipment grounding conductors shall have a continuous outer finish that is either green.

110.3 Examination, Identification, Installation, and Use of Equipment.
(B) Installation and Use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling.
ELE06-00825 Electrical Rough-In3/10/20063/10/20063/10/2006 10:53:23 AMAPART
Phone #: ###-#### Internet Inspection Request from: joe wheeler
underground and partial bonding ok
ELE06-00813 Final3/9/20063/10/20063/10/2006 10:23:16 AMAPASS
reinspection on hot tub, outlet was added off of hot tub disconnect everthing on outside okay to go in yard Internet Inspection Request from: Andy Rose
ELE06-00789 Electrical Rough-In3/10/20063/10/20063/10/2006 10:16:51 AMAPASS
Internet Inspection Request from: Steve Craig
ELE06-00773 Electrical Rough-In3/9/20063/10/20063/10/2006 9:28:14 AMAPASS
Phone #: ###-#### Internet Inspection Request from: todd hall
ELE05-04575 Final3/9/20063/10/20063/10/2006 8:30:51 AMAPASS
reinspection on kitchen remodel. call Tom @###-#### to be let in. Internet Inspection Request from: Andy Rose
ELE06-00441 Electrical Rough-In3/10/20063/10/20063/10/2006 12:00:00 AMPCANC
Phone #: ###-#### Internet Inspection Request from: Phil Baker///Cancel per Phil Baker 3-10-06 eus
ELE06-00773 Permanent Service3/10/20063/10/20063/10/2006 12:00:00 AMPPASS
Phone #: ###-#### Internet Inspection Request from: todd hall
P/S U/G N Ok