MEC16-03056
| Rough-in | 3/10/2017 | 3/10/2017 | 3/10/2017 4:14:30 PM | P | PART |
|
|
rough in condo 207 Phone #: ###-#### Inspection requested via web by Crystal Grant - unit 207 okay to cover
|
MEC16-02172
| Mec-Aging Inspection | 3/10/2017 | 3/10/2017 | 3/10/2017 3:43:27 PM | | CANC |
|
|
|
MEC16-05733
| Pressure Test | 3/10/2017 | 3/10/2017 | 3/10/2017 3:38:22 PM | P | PART |
|
|
Randall Phone #: ###-####-late pm if possible - 60lb gas pass on under ground piping from meter to pool equipment room.
|
MEC17-00428
| Rough-in | 3/10/2017 | 3/10/2017 | 3/10/2017 3:37:13 PM | P | PART |
|
|
Call Mark for access rough in building 9 Phone #: ###-#### Inspection requested via web by David Tully - okay to cover guest rooms in bldg 9
|
MEC17-00877
| Final | 3/10/2017 | 3/10/2017 | 3/10/2017 3:37:12 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Justin Osterhout
|
MEC17-00869
| Pressure Test | 3/10/2017 | 3/10/2017 | 3/10/2017 2:18:45 PM | P | PASS |
|
|
Call 1hr please - Brandon Phone #: ###-#### - 20lb gas
|
MEC17-00869
| Final | 3/10/2017 | 3/10/2017 | 3/10/2017 2:17:48 PM | P | PASS |
|
|
Call 1hr please - Brandon Phone #: ###-####
|
MEC17-00729
| Final | 3/8/2017 | 3/10/2017 | 3/10/2017 2:03:33 PM | P | PASS |
|
|
Homeowner, Lilly Vojvodic ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette
|
MEC16-03546
| Mec-Aging Inspection | 3/10/2017 | 3/10/2017 | 3/10/2017 12:04:16 PM | | CANC |
|
|
wip
|
MEC17-00806
| Final | 3/8/2017 | 3/10/2017 | 3/10/2017 12:02:53 PM | A | FAIL |
|
|
Angie-would like as late am as possible Phone #: ###-####-please call to meet - This should have been a rough in. need to submitt a manual J for approval, Need 1" clearance to combustables from b-vent, need 6" clearance to combustables from single wall vent, need to vent bath fan. Need to get plumbing permit
|
MEC17-00181
| Final | 3/7/2017 | 3/10/2017 | 3/10/2017 11:35:02 AM | A | PASS |
|
|
Homeowner not present, Workers supposed to be there all week. Phone #: ###-#### Inspection requested via web by Mary LaFayette
|
MEC16-02661
| Rough-in | 3/9/2017 | 3/10/2017 | 3/10/2017 10:50:34 AM | A | PART |
|
|
Call Cary for access. Cover for conference room 3rd floor and cover for 6th floor rooms east side. Phone #: ###-#### Inspection requested via web by David Tully - okay to cover guest rooms on the east side of the 6th floor. framing around fire/smoke danpers okay for 3rd floor conference room
|
MEC16-03552
| Mec-Aging Inspection | 3/10/2017 | 3/10/2017 | 3/10/2017 9:46:12 AM | | PASS |
|
|
|
MEC16-03552
| DOC - Permit Finaled | 3/10/2017 | 3/10/2017 | 3/10/2017 9:46:00 AM | A | PASS |
|
|
|
MEC16-05733
| Pressure Test | 3/9/2017 | 3/10/2017 | 3/10/2017 9:31:50 AM | A | PART |
|
|
randall Phone #: ###-#### - 20lb gas pass to fireplace in office bldg. met and looked at underground gas piping to pool heatetrs, bbq, and fire pit. the existing piping is undersized and needs to be brought up to current codes. I spoke with Randall about increasing the gas pressure to a 2lb system with regulators to avoid having to repipe the whole system.
|
MEC17-00797
| Rough-in | 3/9/2017 | 3/10/2017 | 3/10/2017 9:15:06 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Troy Worley
|