MEC17-00843
| Final | 3/10/2017 | 3/10/2017 | 3/10/2017 3:43:40 PM | P | PASS |
|
|
We will notify inspector when we are close to finished. Call Max if you have any questions. ###-#### Thanks! Inspection requested via web by Floyd Floyd Peek
|
MEC17-00356
| Rough-in | 3/8/2017 | 3/10/2017 | 3/10/2017 3:42:12 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Lisa Whitney
|
MEC17-00356
| Pressure Test | 3/8/2017 | 3/10/2017 | 3/10/2017 3:42:01 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Lisa Whitney 20lb gas
|
MEC17-00611
| Pressure Test | 3/10/2017 | 3/10/2017 | 3/10/2017 2:50:08 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Lisa Whitney 60,20lb gas
|
MEC17-00713
| Rough-in | 3/9/2017 | 3/10/2017 | 3/10/2017 2:18:19 PM | P | PASS |
|
|
Light test. Contact Dave DeChambeau @ ###-#### with any questions. Phone #: ###-#### Inspection requested via web by Dave DeChambeau ok to wrap
|
MEC17-00859
| Final | 3/9/2017 | 3/10/2017 | 3/10/2017 1:37:17 PM | P | PASS |
|
|
Homeowner SueAnne Harfst ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette
|
MEC17-00509
| Final | 3/10/2017 | 3/10/2017 | 3/10/2017 1:21:41 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart armaflex needs uv protection
|
MEC17-00898
| Final | 3/9/2017 | 3/10/2017 | 3/10/2017 1:12:44 PM | P | PASS |
|
|
This is for Late Pm if possible. Please call Sam B4 arrival to arrange time and access. Thank You Phone #: ###-#### Inspection requested via web by Diane Day
|
PLM17-00618
| Final | 3/7/2017 | 3/10/2017 | 3/10/2017 11:42:05 AM | P | PASS |
|
|
CALL BILL WITH ANY QUESTIONS OR CONCERNS Phone #: ###-#### Inspection requested via web by Ben Davis 20lb gas
|
MEC17-00872
| Rough-in | 3/9/2017 | 3/10/2017 | 3/10/2017 11:18:58 AM | A | PASS |
|
|
Mechanical Fireplace Rough-In Phone #: ###-#### Inspection requested via web by Dan Otero
|
MEC17-00879
| Pressure Test | 3/9/2017 | 3/10/2017 | 3/10/2017 10:56:38 AM | A | PASS |
|
|
If possible give Shaun a 30 minute notice phone number ###-#### Phone #: ###-#### Inspection requested via web by shaun bevan 20lb gas
|
MEC17-00879
| Final | 3/10/2017 | 3/10/2017 | 3/10/2017 10:56:07 AM | P | PASS |
|
|
If possible give Shaun a 30 minute notice phone number ###-#### Phone #: ###-#### Inspection requested via web by shaun bevan
|
MEC17-00848
| Rough-in | 3/9/2017 | 3/10/2017 | 3/10/2017 10:08:16 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Andrea Creek floor boots need to be sealed to floor, flex in crawl needs to be supported from structure, fresh air needs to run back to plenum, flex tubing not approved for concealed construction
|
MEC17-00848
| Pressure Test | 3/10/2017 | 3/10/2017 | 3/10/2017 10:04:28 AM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Andrea Creek 20lb gas, 5lb flue
|
MEC16-05758
| Final | 3/9/2017 | 3/10/2017 | 3/10/2017 9:34:46 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Dan Otero
|
MEC16-05757
| Final | 3/9/2017 | 3/10/2017 | 3/10/2017 9:34:34 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Dan Otero
|
MEC17-00814
| Final | 3/6/2017 | 3/10/2017 | 3/10/2017 9:14:08 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Ron Apple need to witness flue pressure test, armaflex needs uv protection, caulk lineset coming through brick in garage
|
MEC17-00856
| Rough-in | 3/9/2017 | 3/10/2017 | 3/10/2017 8:55:09 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak floor boots need to be sealed to the floor, dryer vent needs another nailplate so it covers to the bottum of the top plate, return to bedroom 3 doesnt match manual j
|