Inspections for the day of: Friday, March 10, 2017.
Number of inspections: 18
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBen Livingston
TitleMEC-COM/RES INSPECTOR
Phone #576-1208
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC17-00843 Final3/10/20173/10/20173/10/2017 3:43:40 PMPPASS
We will notify inspector when we are close to finished. Call Max if you have any questions. ###-#### Thanks! Inspection requested via web by Floyd Floyd Peek
MEC17-00356 Rough-in3/8/20173/10/20173/10/2017 3:42:12 PMPPASS
Phone #: ###-#### Inspection requested via web by Lisa Whitney
MEC17-00356 Pressure Test3/8/20173/10/20173/10/2017 3:42:01 PMPPASS
Phone #: ###-#### Inspection requested via web by Lisa Whitney
20lb gas
MEC17-00611 Pressure Test3/10/20173/10/20173/10/2017 2:50:08 PMPPASS
Phone #: ###-#### Inspection requested via web by Lisa Whitney
60,20lb gas
MEC17-00713 Rough-in3/9/20173/10/20173/10/2017 2:18:19 PMPPASS
Light test. Contact Dave DeChambeau @ ###-#### with any questions. Phone #: ###-#### Inspection requested via web by Dave DeChambeau
ok to wrap
MEC17-00859 Final3/9/20173/10/20173/10/2017 1:37:17 PMPPASS
Homeowner SueAnne Harfst ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette
MEC17-00509 Final3/10/20173/10/20173/10/2017 1:21:41 PMPFAIL
Phone #: ###-#### Inspection requested via web by Randy Hart
armaflex needs uv protection
MEC17-00898 Final3/9/20173/10/20173/10/2017 1:12:44 PMPPASS
This is for Late Pm if possible. Please call Sam B4 arrival to arrange time and access. Thank You Phone #: ###-#### Inspection requested via web by Diane Day
PLM17-00618 Final3/7/20173/10/20173/10/2017 11:42:05 AMPPASS
CALL BILL WITH ANY QUESTIONS OR CONCERNS Phone #: ###-#### Inspection requested via web by Ben Davis
20lb gas
MEC17-00872 Rough-in3/9/20173/10/20173/10/2017 11:18:58 AMAPASS
Mechanical Fireplace Rough-In Phone #: ###-#### Inspection requested via web by Dan Otero
MEC17-00879 Pressure Test3/9/20173/10/20173/10/2017 10:56:38 AMAPASS
If possible give Shaun a 30 minute notice phone number ###-#### Phone #: ###-#### Inspection requested via web by shaun bevan
20lb gas
MEC17-00879 Final3/10/20173/10/20173/10/2017 10:56:07 AMPPASS
If possible give Shaun a 30 minute notice phone number ###-#### Phone #: ###-#### Inspection requested via web by shaun bevan
MEC17-00848 Rough-in3/9/20173/10/20173/10/2017 10:08:16 AMAFAIL
Phone #: ###-#### Inspection requested via web by Andrea Creek
floor boots need to be sealed to floor,
flex in crawl needs to be supported from structure,
fresh air needs to run back to plenum,
flex tubing not approved for concealed construction
MEC17-00848 Pressure Test3/10/20173/10/20173/10/2017 10:04:28 AMPPASS
Phone #: ###-#### Inspection requested via web by Andrea Creek
20lb gas, 5lb flue
MEC16-05758 Final3/9/20173/10/20173/10/2017 9:34:46 AMAPASS
Phone #: ###-#### Inspection requested via web by Dan Otero
MEC16-05757 Final3/9/20173/10/20173/10/2017 9:34:34 AMAPASS
Phone #: ###-#### Inspection requested via web by Dan Otero
MEC17-00814 Final3/6/20173/10/20173/10/2017 9:14:08 AMAFAIL
Phone #: ###-#### Inspection requested via web by Ron Apple
need to witness flue pressure test, armaflex needs uv protection, caulk lineset coming through brick in garage
MEC17-00856 Rough-in3/9/20173/10/20173/10/2017 8:55:09 AMAFAIL
Phone #: ###-#### Inspection requested via web by Oleg Chervak
floor boots need to be sealed to the floor,
dryer vent needs another nailplate so it covers to the bottum of the top plate,
return to bedroom 3 doesnt match manual j