Inspections for the day of: Monday, March 11, 2013.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE11-02617 ELE-Aging Inspection3/11/20133/11/20133/11/2013 3:54:40 PM DONE
Drove by and posted correction notice
ELE11-02606 ELE-Aging Inspection3/11/20133/11/20133/11/2013 3:43:47 PM DONE
Waiting on owner
ELE12-03031 Electrical Rough-In3/11/20133/11/20133/11/2013 3:06:30 PMPPASS
###-#### cell Phone #: ###-#### >> Inspection requested via web by Mark M
MRI procedure room ceiling rough in ok cover
ELE11-02544 Final3/11/20133/11/20133/11/2013 2:08:13 PMPPASS
final on A/C wiring Phone #: ###-#### >> Inspection requested via web by Andy Rose
No answer at door, able to see AC unit and disconnecting means from alley. Final ok
ELE13-00309 Final3/11/20133/11/20133/11/2013 1:39:33 PMPPASS
calling for final on retrofits. Removed abandoned fixtures center island per Rock H at rough-in. Phone #: ###-#### >> Inspection requested via web by Tim Dunlop Final ok
ELE13-00548 Electrical Rough-In3/11/20133/11/20133/11/2013 1:16:13 PMPPASS
Pool bonding Phone #: ###-#### >> Inspection requested via web by TOM BICANDI
Pool bonding rough in ok cover
ELE13-00550 Electrical Rough-In3/11/20133/11/20133/11/2013 12:43:11 PMPPASS
wire gas furnace Phone #: ###-#### >> Inspection requested via web by PAT MILLER
Gas furnace rough in ok
GCE13-00031 GCE-Rough-In3/11/20133/11/20133/11/2013 12:13:51 PMPPASS
Bill ###-#### Wall rough in ok cover
ELE13-00388 Rough-In Permanent Service3/11/20133/11/20133/11/2013 10:27:23 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Eric Brown Main floor rough in ok cover p/s u/g n ok
ELE13-00147 Final3/8/20133/11/20133/11/2013 9:58:38 AMAPART
This is for a final on the bunk rooms at the firehouse, so they can move back into them.Call me before you will be there 30 mins. if possible. Bob Phone #: ###-#### >> Inspection requested via web by robert feller
Partial final, Bunk rooms and TV room final ok
ELE13-00460 Electrical Rough-In3/8/20133/11/20133/11/2013 9:33:22 AMAPASS
Need roughin inspection for shop with upstairs office. Phone #: ###-#### >> Inspection requested via web by Alan Lusk
Shop rough in ok cover
ELE13-00503 Electrical Rough-In3/11/20133/11/20133/11/2013 8:54:28 AMAPASS
Rough In Of Both Units They Are Ready And ill Be There Thanks Dave Phone #: ###-#### >> Inspection requested via web by jason shifflett
Both units rough in ok cover
ELE13-00512 Final3/8/20133/11/20133/11/2013 8:25:19 AMAPASS
Phone #: ###-#### >> Inspection requested via web by MARK PINNEY
Final ok