MEC19-00756
| Pressure Test | 3/11/2019 | 3/11/2019 | 3/11/2019 4:34:24 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Dave Sorensen - 20lb gas pressure test ok
|
MEC18-05106
| Final | 3/11/2019 | 3/11/2019 | 3/11/2019 3:29:47 PM | P | FAIL |
|
|
LOCKBOX CODE: 1369 - BY BACK DOOR AT HOSE BIB MAN J ; PERMIT IN KITCHEN DRAWER TO RIGHT OF SINK Phone #: ###-#### Inspection requested via web by Bryan Palmer - line set penetration needs sealed - range vent ok
|
MEC19-00420
| Pressure Test | 3/11/2019 | 3/11/2019 | 3/11/2019 3:19:59 PM | P | PASS |
|
|
MARK IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER - 60lb gas pressure test ok - by final will need to see one more support hanger installed for gas line near deli. Gas line turns and runs north and is unsupported. I also talked with Mark at Buss about new gas ovens being set under exhaust hood with at least 6" clearances from edge of hood
|
MEC18-00675
| Final | 3/6/2019 | 3/11/2019 | 3/11/2019 2:55:42 PM | P | FAIL |
|
|
Please call when you are on your way Phone #: ###-#### Inspection requested via web by Andrea Grigsby - called number in notes no one answered. A gentleman answered the door but said this afternoon was a bad time and that he was leaving.
|
MEC19-00881
| Final | 3/11/2019 | 3/11/2019 | 3/11/2019 2:40:05 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Mary LaFayette - furnace only co ok
|
MEC19-00838
| Final | 3/4/2019 | 3/11/2019 | 3/11/2019 2:22:22 PM | P | PASS |
|
|
installer JAROD ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt - furnace only co ok
|
MEC19-00205
| Final | 3/8/2019 | 3/11/2019 | 3/11/2019 1:56:47 PM | P | FAIL |
|
|
Please inspect in the PM and call on way: Wayne ###-####. Customer is hard of hearing, so may need to knock loudly. Phone #: ###-#### Inspection requested via web by Arielle Hendricks - gas line needs a sediment trap installed after shut off valve - furnace needs a disconnect installed
|
MEC19-00955
| Pressure Test | 3/8/2019 | 3/11/2019 | 3/11/2019 1:37:46 PM | P | PASS |
|
|
Please call Chuck on your way - ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks - 20lb gas pressure test ok - tagged meter location
|
MEC19-00624
| Final | 3/5/2019 | 3/11/2019 | 3/11/2019 1:17:01 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Mary LaFayette - furnace only co ok
|
MEC18-04352
| Final | 3/7/2019 | 3/11/2019 | 3/11/2019 1:00:33 PM | P | PASS |
|
|
KEY IN THE FRONT PATIO OUTLET. Phone #: ###-#### Inspection requested via web by Arielle Hendricks - final ok
|
MEC18-02775
| Mec-Aging Inspection | 3/11/2019 | 3/11/2019 | 3/11/2019 11:20:26 AM | | DONE |
|
|
Called mechanical contractor and phone was disconnected. Made a trip the 2312 Pendleton and talked with home owner. She let me inspect the range venting and I found that one seam on the ducting wasn't sealed. She gave me her contractors information which is Andrew Clark with Bright Star. Called Andrew and left a message regarding correction that needs to be made to range venting.
|
MEC18-04704
| Final | 3/11/2019 | 3/11/2019 | 3/11/2019 10:41:13 AM | P | CANC |
|
|
Per conversation with Jack, going through inspection to extend permit date. NOT READY FOR INSPECTION. Phone #: ###-#### Inspection requested via web by Andrew Lam -This was a request for an extension
|
MEC18-04704
| Mec-Request for Extension | 3/11/2019 | 3/11/2019 | 3/11/2019 10:39:46 AM | P | PASS |
|
|
Per conversation with Jack, going through inspection to extend permit date. NOT READY FOR INSPECTION. Phone #: ###-#### Inspection requested via web by Andrew Lam
|
MEC19-00962
| Final | 3/8/2019 | 3/11/2019 | 3/11/2019 10:38:27 AM | A | PASS |
|
|
Please call Kelly Buel at ###-#### Monday Morning 1 hour to arrival, he would like to meet you onsite for this inspection. Phone #: ###-#### Inspection requested via web by kelly Martin - new indoor coil only ok co ok
|
MEC19-00967
| Final | 3/8/2019 | 3/11/2019 | 3/11/2019 10:28:10 AM | A | FAIL |
|
|
Please call Sheldon Lebow 30 min prior to inspection for him to meet you there ###-####.
Garage code 0852 Phone #: ###-#### Inspection requested via web by Sheldon Lebow - This is an inspection on an existing fireplace installed without a permit and owner is trying to sell house. checking the install manual clearances are ok. I need Wholesale fireplaces to install a sleeve on the gasline at the fireplace and the penetration through the exterior. Contractor will make corrections and call for a reinspect
|
MEC19-00731
| Rough-in | 3/10/2019 | 3/11/2019 | 3/11/2019 9:15:38 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Adam Eickmeier - range and bathroom exhaust R/I ok
|
MEC19-00956
| Final | 3/8/2019 | 3/11/2019 | 3/11/2019 8:48:42 AM | A | PASS |
|
|
(2) S/A registers, relocate R/A Phone #: ###-#### Inspection requested via web by Frank Marturello - final ok
|
MEC18-02761
| DOC - Permit Finaled | 3/11/2019 | 3/11/2019 | 3/11/2019 8:22:00 AM | P | PASS |
|
|
final on kitchen range hood ok
|
MEC18-02761
| Mec-Aging Inspection | 3/11/2019 | 3/11/2019 | 3/11/2019 8:21:17 AM | | PASS |
|
|
range is finished
|
MEC19-00687
| Final | 3/8/2019 | 3/11/2019 | 3/11/2019 8:19:42 AM | A | PASS |
|
|
Electrical Permit has passed. Please pass mechanical. Phone #: ###-#### Inspection requested via web by Arielle Hendricks - final ok
|