Inspections for the day of: Monday, March 11, 2019.
Number of inspections: 20
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Reynolds
TitleMEC INSPECTOR
Phone #208-803-2395
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC19-00756 Pressure Test3/11/20193/11/20193/11/2019 4:34:24 PMPPASS
Phone #: ###-#### Inspection requested via web by Dave Sorensen
- 20lb gas pressure test ok
MEC18-05106 Final3/11/20193/11/20193/11/2019 3:29:47 PMPFAIL
LOCKBOX CODE: 1369 - BY BACK DOOR AT HOSE BIB
MAN J ; PERMIT IN KITCHEN DRAWER TO RIGHT OF SINK Phone #: ###-#### Inspection requested via web by Bryan Palmer
- line set penetration needs sealed
- range vent ok
MEC19-00420 Pressure Test3/11/20193/11/20193/11/2019 3:19:59 PMPPASS
MARK IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER
- 60lb gas pressure test ok
- by final will need to see one more support hanger installed for gas line near deli. Gas line turns and runs north and is unsupported. I also talked with Mark at Buss about new gas ovens being set under exhaust hood with at least 6" clearances from edge of hood
MEC18-00675 Final3/6/20193/11/20193/11/2019 2:55:42 PMPFAIL
Please call when you are on your way Phone #: ###-#### Inspection requested via web by Andrea Grigsby
- called number in notes no one answered. A gentleman answered the door but said this afternoon was a bad time and that he was leaving.
MEC19-00881 Final3/11/20193/11/20193/11/2019 2:40:05 PMPPASS
Phone #: ###-#### Inspection requested via web by Mary LaFayette
- furnace only co ok
MEC19-00838 Final3/4/20193/11/20193/11/2019 2:22:22 PMPPASS
installer JAROD ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt
- furnace only co ok
MEC19-00205 Final3/8/20193/11/20193/11/2019 1:56:47 PMPFAIL
Please inspect in the PM and call on way: Wayne ###-####. Customer is hard of hearing, so may need to knock loudly. Phone #: ###-#### Inspection requested via web by Arielle Hendricks
- gas line needs a sediment trap installed after shut off valve
- furnace needs a disconnect installed
MEC19-00955 Pressure Test3/8/20193/11/20193/11/2019 1:37:46 PMPPASS
Please call Chuck on your way - ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks
- 20lb gas pressure test ok
- tagged meter location
MEC19-00624 Final3/5/20193/11/20193/11/2019 1:17:01 PMPPASS
Phone #: ###-#### Inspection requested via web by Mary LaFayette
- furnace only co ok
MEC18-04352 Final3/7/20193/11/20193/11/2019 1:00:33 PMPPASS
KEY IN THE FRONT PATIO OUTLET. Phone #: ###-#### Inspection requested via web by Arielle Hendricks
- final ok
MEC18-02775 Mec-Aging Inspection3/11/20193/11/20193/11/2019 11:20:26 AM DONE
Called mechanical contractor and phone was disconnected. Made a trip the 2312 Pendleton and talked with home owner. She let me inspect the range venting and I found that one seam on the ducting wasn't sealed. She gave me her contractors information which is Andrew Clark with Bright Star. Called Andrew and left a message regarding correction that needs to be made to range venting.
MEC18-04704 Final3/11/20193/11/20193/11/2019 10:41:13 AMPCANC
Per conversation with Jack, going through inspection to extend permit date. NOT READY FOR INSPECTION. Phone #: ###-#### Inspection requested via web by Andrew Lam
-This was a request for an extension
MEC18-04704 Mec-Request for Extension3/11/20193/11/20193/11/2019 10:39:46 AMPPASS
Per conversation with Jack, going through inspection to extend permit date. NOT READY FOR INSPECTION. Phone #: ###-#### Inspection requested via web by Andrew Lam
MEC19-00962 Final3/8/20193/11/20193/11/2019 10:38:27 AMAPASS
Please call Kelly Buel at ###-#### Monday Morning 1 hour to arrival, he would like to meet you onsite for this inspection. Phone #: ###-#### Inspection requested via web by kelly Martin
- new indoor coil only ok co ok
MEC19-00967 Final3/8/20193/11/20193/11/2019 10:28:10 AMAFAIL
Please call Sheldon Lebow 30 min prior to inspection for him to meet you there ###-####.

Garage code 0852 Phone #: ###-#### Inspection requested via web by Sheldon Lebow
- This is an inspection on an existing fireplace installed without a permit and owner is trying to sell house. checking the install manual clearances are ok. I need Wholesale fireplaces to install a sleeve on the gasline at the fireplace and the penetration through the exterior.
Contractor will make corrections and call for a reinspect
MEC19-00731 Rough-in3/10/20193/11/20193/11/2019 9:15:38 AMAPASS
Phone #: ###-#### Inspection requested via web by Adam Eickmeier
- range and bathroom exhaust R/I ok
MEC19-00956 Final3/8/20193/11/20193/11/2019 8:48:42 AMAPASS
(2) S/A registers, relocate R/A Phone #: ###-#### Inspection requested via web by Frank Marturello
- final ok
MEC18-02761 DOC - Permit Finaled3/11/20193/11/20193/11/2019 8:22:00 AMPPASS
final on kitchen range hood ok
MEC18-02761 Mec-Aging Inspection3/11/20193/11/20193/11/2019 8:21:17 AM PASS
range is finished
MEC19-00687 Final3/8/20193/11/20193/11/2019 8:19:42 AMAPASS
Electrical Permit has passed. Please pass mechanical. Phone #: ###-#### Inspection requested via web by Arielle Hendricks
- final ok