ELE06-04521
| ELE-Aging Inspection | 3/12/2007 | 3/12/2007 | 3/15/2007 3:30:01 PM | | DONE |
|
|
called contr to check status of permit
|
ELE07-00008
| Final | 3/12/2007 | 3/12/2007 | 3/12/2007 3:27:37 PM | P | NH |
|
|
candy or sharon - pls call for secaurity code; Phone #: ###-#### Internet Inspection Request from: Victoria Beall called for code, no lock box, need to call when available
|
ELE07-00114
| Electrical Rough-In | 3/12/2007 | 3/12/2007 | 3/12/2007 2:17:23 PM | P | FAIL |
|
|
Final - if you have questions pls call Mike @ ###-####. Thank! Scheduled by Heather W/ Doherty Phone #: ###-#### called, left messag, left corr notice, nec 408.4 circuit directory shall be clear, concise, and legibly identified, with circuits specific, 110.12(A) ,408.&, unused openings in panels shall be closed, 240.81 circuit breaker handle shall be up for on and down for off, 406.5 recpt faceplates shall completely cover openings, 330.30(B) mc cable shall be strapped within 12" of box, 358.30(A) emt shall be strapped within 3' of box, 422.31(B) shall provide disconnect or lockout for appliances, water heater, 250.104(A) h & c water piping shall be bonded, 110.26 there shall be no foreign piping in work space about equipment, BCC all make-up shall be done-below service panel,all equipment shall be listed by a nationally recognized testing laboratory (furniture), and all covers installed, meter shall be weatherproof
|
ELE07-00811
| Final | 3/12/2007 | 3/12/2007 | 3/12/2007 12:46:37 PM | P | PASS |
|
|
Work performed by Steve Johnson. Phone #: ###-#### p/s o/h rec ok, talked to elect to provide abrasion protection for gec at service panel
|
ELE07-00775
| Rough-In Permanent Service | 3/12/2007 | 3/12/2007 | 3/12/2007 10:32:48 AM | A | PASS |
|
|
Phone #: ###-#### ric ok, p/s u/g n ok, 4 meters
|
ELE07-00692
| Rough-In Permanent Service | 3/9/2007 | 3/12/2007 | 3/12/2007 9:48:26 AM | A | CANC |
|
|
Phone #: ###-#### see ri and p/s
|
ELE07-00692
| Electrical Rough-In | 3/12/2007 | 3/12/2007 | 3/12/2007 9:45:08 AM | A | FAIL |
|
|
Phone #: ###-#### called contr, left corr notice, nec 300.4(A)&(D) edge of bored holes and nm cable shall be 1 1/4" from edge of framing member, 250.86 all metal boxes shall be grounded, 300.14 at least 6" of free conductor shall be provided at each box, 314.16 boxes shall be of sufficient size to provide free space for conductors (rear garage pan with 2 nm cables), BCC all make-up shall be done, all u/g shall be inspected before cover
|
ELE07-00692
| Permanent Service | 3/12/2007 | 3/12/2007 | 3/12/2007 9:40:31 AM | A | PASS |
|
|
Phone #: ###-#### p/s u/g n ok
|
ELE07-00153
| Final | 3/9/2007 | 3/12/2007 | 3/12/2007 8:57:31 AM | A | CANC |
|
|
###-#### THANK YOU. Phone #: ###-#### x0000 called number, didn't know about job, called office,got elect number, called, he was quite a way out and needs to meet on job, said to call for another inspection and set up appointment to meet elect
|
ELE07-00798
| Final | 3/9/2007 | 3/12/2007 | 3/12/2007 8:34:25 AM | A | PASS |
|
|
vern - across the street from storage facility; Phone #: ###-#### Internet Inspection Request from: Victoria Beall see p/s, ok to final, called contr on address
|
ELE07-00798
| Permanent Service | 3/12/2007 | 3/12/2007 | 3/12/2007 8:33:10 AM | A | PASS |
|
|
vern - across the street from storage facility; Phone #: ###-#### Internet Inspection Request from: Victoria Beall p/s u/g n ok
|
ELE05-04325
| Final | 3/9/2007 | 3/12/2007 | 3/12/2007 8:16:19 AM | A | PART |
|
|
Jason; Phone #: ###-#### Internet Inspection Request from: Stacie Backus kitchen area ok to final anop
|