ELE11-01109
| ELE-Aging Inspection | 3/12/2013 | 3/12/2013 | 3/13/2013 2:14:55 PM | | DONE |
|
|
called, left message to call for final
|
ELE11-01079
| ELE-Aging Inspection | 3/12/2013 | 3/12/2013 | 3/13/2013 2:12:02 PM | | DONE |
|
|
called, asked owner to call for final
|
ELE11-02601
| Final | 3/12/2013 | 3/12/2013 | 3/12/2013 2:41:14 PM | P | PASS |
|
|
ok final
|
ELE12-02570
| Final | 3/11/2013 | 3/12/2013 | 3/12/2013 2:12:29 PM | P | PASS |
|
|
installed 1 wall sign. Primary Power by others Phone #: ###-#### >> Inspection requested via web by Ken Olsen ok final
|
ELE13-00552
| Temporary Service | 3/11/2013 | 3/12/2013 | 3/12/2013 1:21:11 PM | P | FAIL |
|
|
Contact: Garrett Collins, call before going please Phone #: ###-#### >> Inspection requested via web by Deb Gooden called, left correction notice, NEC 210.53(G) grounding electrode shall not be driven at less than 45 degree angle, 408.4 shall provide circuit directory, 400.5(A) #4 soow only rated at 60A, trailer requires min 100A service, 590.6(1) cord outlet requires gfci protection
|
ELE13-00299
| Electrical Rough-In | 3/12/2013 | 3/12/2013 | 3/12/2013 12:19:56 PM | P | PASS |
|
|
Floor heat inspection in master bath. Will be ready right before lunch. Please call to schedule someone to meet. Thank you Phone #: ###-#### >> Inspection requested via web by Eric Brown ok cover floor heat
|
ELE12-00745
| Final | 3/11/2013 | 3/12/2013 | 3/12/2013 10:02:43 AM | A | PASS |
|
|
Chuck Phone #: ###-#### ok final
|
ELE13-00058
| Final | 3/11/2013 | 3/12/2013 | 3/12/2013 9:18:39 AM | A | PASS |
|
|
Please call Dan (homeowner) at ###-#### with 15 minutes heads up so he can meet you there.
Thanks, Barbara Szurgot Phone #: ###-#### >> Inspection requested via web by Barbara Szurgot ok final
|
ELE13-00358
| Electrical Rough-In | 3/11/2013 | 3/12/2013 | 3/12/2013 8:47:31 AM | A | PASS |
|
|
phil Phone #: ###-#### ok cover u/g east 1/2 field 2
|
ELE13-00511
| Electrical Rough-In | 3/11/2013 | 3/12/2013 | 3/12/2013 8:22:34 AM | A | PASS |
|
|
need a ceiling cover inspection call corey with questions thanks for your time Phone #: ###-#### >> Inspection requested via web by Don Lustig ok cover ceiling
|