MEC18-00920
| Rough-in | 3/12/2018 | 3/12/2018 | 3/12/2018 4:12:37 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by dannyel chaloupka- b vent in garage ceiling needs 1" clearance to combustibles, once sheetrock is installed wont have clearance- need to move to the south- missing transfer register in master bedroom 1st floor- left notice front window
|
MEC18-00920
| Pressure Test | 3/12/2018 | 3/12/2018 | 3/12/2018 4:11:08 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by dannyel chaloupka- 20lb gas pass
|
MEC18-01106
| Rough-in | 3/9/2018 | 3/12/2018 | 3/12/2018 3:36:35 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart- need approved ACCA report onsite to do inspection
|
MEC18-01106
| Pressure Test | 3/9/2018 | 3/12/2018 | 3/12/2018 3:36:07 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart- gas and flue tests fail
|
MEC18-01107
| Rough-in | 3/9/2018 | 3/12/2018 | 3/12/2018 3:35:36 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart- firestops need to be installed every 10 feet- needs installed at level 1 ceiling
|
MEC18-00976
| Rough-in | 3/12/2018 | 3/12/2018 | 3/12/2018 2:54:37 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by dannyel chaloupka- gas test failed- dryer vent can not be installed in 3.5 inch wall needs to be firred out- ALL ehaust fans need to be taped/sealed where ties onto fan- 16" round R/A pinched to 9 inches where ties onto register in hallway- left correction notice front window
|
MEC18-00976
| Pressure Test | 3/12/2018 | 3/12/2018 | 3/12/2018 2:51:42 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by dannyel chaloupka- gauge at 8 psi- test failed
|
MEC18-01109
| Final | 3/9/2018 | 3/12/2018 | 3/12/2018 2:21:25 PM | P | PASS |
|
|
INSTALLER DAVID ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace ac co ok
|
MEC18-00957
| Pressure Test | 3/12/2018 | 3/12/2018 | 3/12/2018 1:40:18 PM | P | PASS |
|
|
pvc flue pressure test. door by garage is open gauge is in the basement Phone #: ###-#### Inspection requested via web by Dave Sorensen- 5lb flue pass
|
MEC18-01129
| Final | 3/12/2018 | 3/12/2018 | 3/12/2018 1:21:05 PM | P | PASS |
|
|
gas pipe and pressure ok- co ok
|
MEC18-01129
| Pressure Test | 3/9/2018 | 3/12/2018 | 3/12/2018 1:19:46 PM | P | PASS |
|
|
Please call when on the way. Phone #: ###-#### Inspection requested via web by Steve Bunch- 20lb gas pass
|
MEC18-00544
| Rough-in | 3/8/2018 | 3/12/2018 | 3/12/2018 12:01:27 PM | A | PASS |
|
|
Field super : Daryl Thomas Phone #: ###-#### Inspection requested via web by Lisa Whitney- R/I both units ok
|
MEC18-00544
| Pressure Test | 3/8/2018 | 3/12/2018 | 3/12/2018 12:01:05 PM | A | PASS |
|
|
Field super : Daryl Thomas Phone #: ###-#### Inspection requested via web by Lisa Whitney- 20lb gas pass both units
|
MEC18-00341
| Final | 3/9/2018 | 3/12/2018 | 3/12/2018 11:48:49 AM | A | PART |
|
|
final - call jeremy Phone #: ###-#### Inspection requested via web by Brandon Sorensen- need other mech permit frm different contractor called in for final before can final out this permit- final ok
|
MEC18-00370
| Final | 3/12/2018 | 3/12/2018 | 3/12/2018 11:39:31 AM | A | PASS |
|
|
correction made-
|
MEC17-04883
| Final | 3/12/2018 | 3/12/2018 | 3/12/2018 11:13:32 AM | P | PASS |
|
|
Contact Rich Beckstead ###-####. Phone #: ###-#### Inspection requested via web by Beka Hereau- final ok- card signed permanent occupancy
|
MEC17-01679
| Mec-Aging Inspection | 3/12/2018 | 3/12/2018 | 3/12/2018 10:58:33 AM | | PEND |
|
|
contractor to schedule final inspection per text
|
MEC18-01036
| Final | 3/5/2018 | 3/12/2018 | 3/12/2018 10:29:51 AM | A | PASS |
|
|
Please contact Kyle before going as he will need to meet you at the jobsite for the pressure test. ###-#### Phone #: ###-#### Inspection requested via web by Rick Borg- furnace co ok
|
MEC18-01036
| Pressure Test | 3/5/2018 | 3/12/2018 | 3/12/2018 10:29:28 AM | A | PASS |
|
|
Please contact Kyle before going as he will need to meet you at the jobsite for the pressure test. ###-#### Phone #: ###-#### Inspection requested via web by Rick Borg- 5lb flue pass
|
MEC17-02909
| Mec-Aging Inspection | 3/12/2018 | 3/12/2018 | 3/12/2018 10:05:25 AM | | PEND |
|
|
contractor will schedule final per phone call
|
MEC17-05763
| Final | 3/9/2018 | 3/12/2018 | 3/12/2018 10:04:08 AM | A | PASS |
|
|
call Mike for access: ###-#### Phone #: ###-#### Inspection requested via web by Frank Marturello- final ok
|
MEC18-01087
| Final | 3/12/2018 | 3/12/2018 | 3/12/2018 9:48:21 AM | A | PASS |
|
|
no mantel will be installed- fireplace ok
|
MEC18-01087
| Rough-in | 3/9/2018 | 3/12/2018 | 3/12/2018 9:47:36 AM | A | PASS |
|
|
Inspection requested via web by Ashley Stegemann- fireplace R/I ok
|
MEC18-01087
| Pressure Test | 3/12/2018 | 3/12/2018 | 3/12/2018 9:47:15 AM | A | CANC |
|
|
no pressure test needed under 10 feet
|
MEC17-05498
| Pressure Test | 3/12/2018 | 3/12/2018 | 3/12/2018 9:28:13 AM | A | PASS |
|
|
20lb gas underground from meter to BBQ location ok- yellow tracer wire installed- ok for back fill
|
MEC18-01089
| Rough-in | 3/9/2018 | 3/12/2018 | 3/12/2018 8:59:55 AM | A | PASS |
|
|
Inspection requested via web by Ashley Stegemann- fireplace R/I ok
|
MEC18-01089
| Pressure Test | 3/9/2018 | 3/12/2018 | 3/12/2018 8:59:37 AM | P | PASS |
|
|
Inspection requested via web by Ashley Stegemann- 20lb gas pass
|
MEC18-00973
| Rough-in | 3/12/2018 | 3/12/2018 | 3/12/2018 8:36:41 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by dannyel chaloupka- R/I ok
|
MEC18-00973
| Pressure Test | 3/12/2018 | 3/12/2018 | 3/12/2018 8:36:24 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by dannyel chaloupka- 20lb gas pass
|
MEC18-01010
| Rough-in | 3/9/2018 | 3/12/2018 | 3/12/2018 8:23:14 AM | A | PASS |
|
|
Inspection requested via web by Ashley Stegemann- fireplace R/I ok
|
MEC18-00368
| Final | 3/9/2018 | 3/12/2018 | 3/12/2018 8:13:55 AM | A | PASS |
|
|
Inspection requested via web by Ashley Stegemann- fireplace final ok
|
MEC18-00976
| Rough-in | 3/9/2018 | 3/12/2018 | 3/12/2018 7:21:33 AM | A | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Debbie Marino Inspection cancelled from web by: dannyel chaloupka
|
MEC18-00976
| Pressure Test | 3/9/2018 | 3/12/2018 | 3/12/2018 7:21:29 AM | A | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Debbie Marino Inspection cancelled from web by: dannyel chaloupka
|