Inspections for the day of: Thursday, March 13, 2008.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorEric Strole
TitlePLM/MEC-INSPECTOR
Phone #794-7913
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM08-00493 Other3/12/20083/13/20083/13/2008 4:52:10 PMPPART
this is a walk thru with bill thompson-(downstairs kitchen)water cooled condenser needs a rpba, glass dishwasher needs a rpba, pot filler needs a faucet with a airgap or an rpba. (upstairs kitchen) dishwasher needs a rpba, soap dispenser above mop sink needs to be on own water line with a rpba & or change soap dispenser to one with an airgap then no rpba is required.(no valves downstream of a avb) corrections on hand sink are complete, temp final ok.
PLM07-03630 Final3/12/20083/13/20083/13/2008 4:08:08 PMPPASS
Henry is contact. Thanks. Phone #: ###-#### Internet Inspection Request from: Mike Davisson
PLM07-03509 Final3/13/20083/13/20083/13/2008 3:54:18 PMPCANC
On site contact is Corry @ ###-####. Phone #: ###-#### Internet Inspection Request from: Jane Amy
PLM08-00520 Water and/or Sewer3/13/20083/13/20083/13/2008 1:40:36 PMPPART
water line needs to be 36" deep at last 3" at back of house. ok to cover up to that point.
PLM08-00518 Plumbing Rough-in3/12/20083/13/20083/13/2008 1:14:15 PMAPASS
shawn Note: apt #2 Phone #: ###-####
PLM08-00520 Water and/or Sewer3/13/20083/13/20083/13/2008 1:13:44 PMPCANC
john Phone #: ###-####
PLM08-00511 Plumbing Rough-in3/12/20083/13/20083/13/2008 11:24:10 AMAPASS
sandy Phone #: ###-####
PLM08-00513 Plumbing Rough-in3/12/20083/13/20083/13/2008 10:52:14 AMAPASS
please call in am so pressure can be held up on plumbing,Steve Olson. Thank you Phone #: ###-#### Internet Inspection Request from: Mary Treese
PLM07-04027 Plumbing Rough-in3/12/20083/13/20083/13/2008 10:01:46 AMAPASS
ken Phone #: ###-####
PLM08-00444 Plumbing Rough-in3/11/20083/13/20083/13/2008 9:37:13 AMAPASS
Ready by 10:00AM. Phone #: ###-#### Internet Inspection Request from: John Hensley
PLM08-00444 DOC - Permit Finaled3/13/20083/13/20083/13/2008 9:37:02 AMPPASS
Ready by 10:00AM. Phone #: ###-#### Internet Inspection Request from: John Hensley
PLM07-02062 Plumbing Rough-in3/12/20083/13/20083/13/2008 9:23:34 AMAPART
section of water lines complete makked on plans.
PLM07-02062 Roof Drains3/12/20083/13/20083/13/2008 9:22:32 AMAPART
sections of roof drains complete marked on plans.
PLM07-03723 Final3/12/20083/13/20083/13/2008 7:45:17 AMAPASS
joe Phone #: ###-####
PLM07-03723 DOC - Permit Finaled3/13/20083/13/20083/13/2008 7:45:06 AMPPASS
joe Phone #: ###-####