Inspections for the day of: Thursday, March 14, 1996.
Number of inspections: 19
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJim Sly
TitleBLD-COM/RES INSPECTOR
Phone #794-9465
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD95-01511 INSP - Letter of compliance3/14/19963/14/19963/14/1996 12:00:00 AM PASS
/ / 316 - C/C #10577
BLD95-01511 INSP - Letter of compliance3/14/19963/14/19963/14/1996 12:00:00 AM PASS
/ / 316 - C/C #10577
BLD95-01511 INSP - Letter of compliance3/14/19963/14/19963/14/1996 12:00:00 AM PASS
/ / 316 - C/C #10577
BLD95-01511 INSP - Letter of compliance3/14/19963/14/19963/14/1996 12:00:00 AM PASS
/ / 316 - C/C #10577
BLD95-01938 INSP - Letter of compliance3/14/19963/14/19963/14/1996 12:00:00 AM PASS
/ / 316 - C/C # 10578
BLD95-01938 INSP - Letter of compliance3/14/19963/14/19963/14/1996 12:00:00 AM PASS
/ / 316 - C/C # 10578
BLD95-01938 INSP - Letter of compliance3/14/19963/14/19963/14/1996 12:00:00 AM PASS
/ / 316 - C/C # 10578
BLD95-01938 INSP - Letter of compliance3/14/19963/14/19963/14/1996 12:00:00 AM PASS
/ / 316 - C/C # 10578
BLD95-01938 INSP - Final3/13/19963/14/19963/14/1996 12:00:00 AMAPASS
03/13/96 316 - OK..C/C #10578
BLD95-01511 INSP - Final3/13/19963/14/19963/14/1996 12:00:00 AMAPASS
03/13/96 316 - CALL BOB - ###-#### OK C/C #10577
MEC96-00166 INSP - Final3/13/19963/14/19963/14/1996 12:00:00 AMPCANC
03/14/96 316 - Swamped....Gave to Alan H.
MEC96-00166 INSP - Final3/13/19963/14/19963/14/1996 12:00:00 AMPCANC
03/14/96 316 - Swamped....Gave to Alan H.
MEC96-00760 INSP - Rough-in & Gas Pressure3/14/19963/14/19963/14/1996 12:00:00 AMPCANC
03/14/96 316 - Swamped....Gave to Alan H.
MEC96-00772 INSP - Rough-in & Gas Pressure3/14/19963/14/19963/14/1996 12:00:00 AMPCANC
03/14/96 316 - Swamped.....Gave to Alan H.
BLD1053909 INSP - Energy code compliance3/14/19963/14/19963/14/1996 12:00:00 AMPPASS
03/14/96 316 - Insulation OK. Checked Metacaulk fittings and tub pan f left note for Darrel to repair small hole in draftstop in attic.
BLD95-02116 INSP - Footings3/14/19963/14/19963/14/1996 12:00:00 AMPPART
03/14/96 316 - Poured W/O inspection.....2/3rds complete when I arrived Re-bar complete...cover and laps OK on what I could see.
BLD95-02175 INSP - Footings3/14/19963/14/19963/14/1996 12:00:00 AMPPASS
03/14/96 316 - EARLY PM. Inspected footings at South and West walls of rear of existing stone structure...Re-bar as per plans, good cover and verts were tied...not wet set. Soil good.
BLD96-00164 INSP - Framing/Rough-in3/13/19963/14/19963/14/1996 12:00:00 AMPPASS
03/14/96 316 - FRAMING SUB-FLOOR ...OK Sub floor inspection complete.
BLD96-00273 INSP - Final3/14/19963/14/19963/14/1996 12:00:00 AMPFAIL
03/14/96 316 - Correction notice for no smoke detectors in Bedrooms and gyp to existing overhead garage door wall.