ELE05-04488
| ELE-Aging Inspection | 3/14/2006 | 3/14/2006 | 3/16/2006 8:19:46 AM | | DONE |
|
|
see final
|
ELE05-04598
| Final | 3/14/2006 | 3/14/2006 | 3/14/2006 4:32:24 PM | P | PASS |
|
|
ron; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ok to final
|
ELE06-00274
| Final | 3/14/2006 | 3/14/2006 | 3/14/2006 4:22:47 PM | P | PASS |
|
|
Sean; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong ok to final
|
ELE05-04259
| Final | 3/14/2006 | 3/14/2006 | 3/14/2006 3:13:36 PM | P | NR |
|
|
Scheduled by a contractor via Hello! on 3/14/2006 at 6:01:30 AM. Contact: ###-####. elect was held up, told to re-call
|
ELE06-00866
| Electrical Rough-In | 3/14/2006 | 3/14/2006 | 3/14/2006 2:59:24 PM | P | PASS |
|
|
charlie Internet Inspection Request from: Melyne Davis ric ok
|
ELE06-00875
| Electrical Rough-In | 3/14/2006 | 3/14/2006 | 3/14/2006 2:49:30 PM | P | FAIL |
|
|
lloyd ###-#### called cont, left corr notice, 300.4(A)&(D) edge of holes and nm cable shall be 1 1/4" from edge of framing members, 210.11(C) kitchen shall be supplied with at least 2 20a small appliance branch circuits for recpt outlets,210.52(C)(1) recpt outlets shall be installed so that no point along the wall line is more than 24" from an outlet( by sink), 410.16(A) outlet box shall be installed to support luminaire
|
ELE06-00657
| Electrical Rough-In | 3/10/2006 | 3/14/2006 | 3/14/2006 1:09:20 PM | P | PASS |
|
|
1st Floor - Sign Shop; Phone #: ###-#### Internet Inspection Request from: Celinda Winters walls and shop ceiling ok to cover
|
ELE05-02631
| Permanent Service | 3/10/2006 | 3/14/2006 | 3/14/2006 1:07:59 PM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Celinda Winters p/s u/g n ok
|
ELE06-00819
| Permanent Service | 3/14/2006 | 3/14/2006 | 3/14/2006 12:07:28 PM | P | PASS |
|
|
roy ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie p/s u/g n ok
|
ELE05-04467
| Final | 3/13/2006 | 3/14/2006 | 3/14/2006 11:41:45 AM | A | FAIL |
|
|
please look at trench work also///Phone #: ###-#### Internet Inspection Request from: todd hall called contr, left corr notice,210.63, shall provide 125 v single phase recpt (gfci) for rooftop, 300.5 u/g shall be 24" under drive, 110.3(B) gfci shall operate,408.4 panel sched shall be complete
|
ELE05-04411
| Final | 3/13/2006 | 3/14/2006 | 3/14/2006 11:39:01 AM | A | FAIL |
|
|
vivian; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa called contr, left corr notice, 110.12(C) service panel door shall operate and access shall be available,entry and back shall be accessible. rest of house ok
|
ELE06-00089
| Final | 3/13/2006 | 3/14/2006 | 3/14/2006 10:56:48 AM | A | PASS |
|
|
access code 3174; Phone #: ###-#### Internet Inspection Request from: ERIC CENTERS called, left survey, 352.30 rnc shall be strapped within 3' of panel,440.4 a/c shall be protected by nameplate data
|
ELE06-00858
| Final | 3/13/2006 | 3/14/2006 | 3/14/2006 10:53:12 AM | A | CANC |
|
|
final inspection on hot tub installation. call Bill Wozniak for access @ ###-####. thank you.; Phone #: ###-#### Internet Inspection Request from: BRIAN KEITH called contr, told them can't do inspection until we see u/g
|
ELE05-04639
| Electrical Rough-In | 3/13/2006 | 3/14/2006 | 3/14/2006 8:33:48 AM | A | PASS |
|
|
CONTACT: MIKE ROBINSON - CEILING INSPECTION; Phone #: ###-#### Internet Inspection Request from: Deb McCoy called contr to tie a few ceiling support wires top and bottom, ceiling cover ok
|
ELE06-00113
| Electrical Rough-In | 3/10/2006 | 3/14/2006 | 3/14/2006 8:16:40 AM | A | PART |
|
|
CONTACT: LYLE DEAN - ROUGH IN INSPECTION 6TH FLOOR; Phone #: ###-#### Internet Inspection Request from: Deb McCoy walls only anop,6th fl
|
ELE06-00819
| Final | 3/14/2006 | 3/14/2006 | 3/14/2006 12:00:00 AM | P | PASS |
|
|
ok to final
|
ELE05-02001
| Final | 3/14/2006 | 3/14/2006 | 3/14/2006 12:00:00 AM | P | PASS |
|
|
ok to final
|
ELE05-04308
| Final | 3/14/2006 | 3/14/2006 | 3/14/2006 12:00:00 AM | P | PASS |
|
|
ok to final
|