PDS Online
Making
Boise
the most livable city in the country.
Home
Permits
Search by Permit Number
How to search by permit number
Search by Address
Search by Customer Number
Search by Current Planning Number
Search in Project by Permit Number
Search by Project Name
Inspections
Search by Permit Number
Search by Request Date
Search by Company Name
Fees
Impact Fees Estimate Calculator
Other Searches
Search for Licensed Contractors
Search Parcel by Address
Search Historical Surveys
Reports
Daily Reports
Weekly Reports
Monthly Reports
Home
/
Inspections
/
Inspector Activity
Inspections for the day of:
Monday, March 14, 2011
.
Number of inspections:
15
Percentage of inspections complete:
100 %
Percentage of inspections not complete:
0 %
Contact Information
Inspector
Clint A Smith
Title
EROSION CONTROL INSPECTOR
Phone #
794-8996
Permit Number
Description
Received
Requested
Completed
AM/PM
Disposition
ESC10-00910
General Inspection
3/14/2011
3/14/2011
3/15/2011 3:03:46 PM
PASS
ESC11-00096
Site Preparation
3/14/2011
3/14/2011
3/15/2011 1:43:03 PM
NR
ESC11-00091
Site Preparation
3/7/2011
3/14/2011
3/14/2011 3:39:18 PM
A
NR
ESC11-00109
Site Preparation
3/10/2011
3/14/2011
3/14/2011 3:23:41 PM
A
DONE
Staging equiptment but will not begin until tomorrow. will re-inspect on 3/15/2011
ESC10-00618
General Inspection
3/11/2011
3/14/2011
3/14/2011 2:47:08 PM
A
PASS
ESC10-00619
General Inspection
3/11/2011
3/14/2011
3/14/2011 2:46:42 PM
A
PASS
ESC11-00111
Site Preparation
3/14/2011
3/14/2011
3/14/2011 2:22:58 PM
NR
ESC11-00117
Conference
3/11/2011
3/14/2011
3/14/2011 2:12:58 PM
P
DONE
REFER TO INSPECTOR 420 NOTES.
ESC11-00100
Site Preparation
3/7/2011
3/14/2011
3/14/2011 2:12:01 PM
A
NR
ESC10-00847
General Inspection
3/14/2011
3/14/2011
3/14/2011 2:11:49 PM
PASS
No run off coming from the lot.
ESC10-00754
Random Inspection
3/14/2011
3/14/2011
3/14/2011 2:11:22 PM
A
FAIL
Verbal to RP:
Replace the sediment barrier at the front of the project behind the guttter pan.
ESC10-00814
Tracking Control
3/11/2011
3/14/2011
3/14/2011 2:10:32 PM
A
FAIL
Spoke with RP and told him he must restrict the construction traffic to one side and more frequently sweep up all hard surfaces.
ESC10-00444
BMP Violation
3/14/2011
3/14/2011
3/14/2011 10:37:15 AM
A
FAIL
Verbal to RP:
Install a sediment barrier along the back of gutter pan. Will reinspect on 3/16/2011AM.
ESC10-00853
General Inspection
3/14/2011
3/14/2011
3/14/2011 10:31:09 AM
PASS
ESC11-00102
Site Preparation
3/10/2011
3/14/2011
3/14/2011 9:46:04 AM
P
FAIL
Verbal to RP:
Install the additional BMP's to the project areathat are shown on the ESC plan map that was approved per Boise City Erosion Control. (Storm drain inlet protection, Filtrex sock on curb cut out, and stabilized construction exits)
** Will allow the exits to be constructed with 2" cruched concrete. If it starts to be broken down dur to traffic the RP is required to do a top dressing of 2" or greater washed rock or 2" or greater basalt angular rock.
Install all storm drain inlet protection per the manufactures specifications.
Clean up all sediment deposits on the hard surfaces. Will re-inspect on 3/15/2011AM.