Inspections for the day of: Friday, March 14, 2014.
Number of inspections: 22
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJim Storey
TitleBLD-COM/RES INSPECTOR
Phone #794-9490
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD14-00337 BLD-Foundation3/13/20143/14/20143/14/2014 4:42:48 PMPPASS
Mike Phone #: ###-####
BLD14-00558 BLD-Final3/14/20143/14/20143/14/2014 4:34:11 PMPPASS
BLD13-02244 BLD-Framing/Rough-in3/13/20143/14/20143/14/2014 4:22:54 PMPPART
late afternoon - craig Phone #: ###-#### aming of 3 hr wall and core board ok to start 5/8 gyp.
BLD14-00495 BLD-Final3/14/20143/14/20143/14/2014 3:42:39 PMPPASS
for restaurant occupancy // Roger Phone #: ###-####
BLD13-00906 BLD-Framing/Rough-in3/13/20143/14/20143/14/2014 2:57:29 PMAFAIL
Teri Phone #: ###-#### duct in 2 hr wall no protection/ backing ada
BLD13-03070 BLD-Final3/13/20143/14/20143/14/2014 2:51:44 PMPPASS
Joe Phone #: ###-####
BLD13-03070 DOC - Permit Finaled3/14/20143/14/20143/14/2014 2:50:19 PMPPASS
BLD14-00258 BLD-Final3/13/20143/14/20143/14/2014 2:36:41 PMAPASS
Todd Phone #: ###-####
BLD14-00558 BLD-Final3/14/20143/14/20143/14/2014 2:17:45 PMPDEFR
Ron Ramza-PLease call at least 30 mins prior to inspection Phone #: ###-#### no access
BLD14-00557 BLD-Final3/14/20143/14/20143/14/2014 2:16:26 PMPPART
Ron Ramza-PLease call at least 30 mins prior to inspection Phone #: ###-#### two door knobs single funtion egress/ cloth ceilling removed. ele cover.
BLD14-00556 BLD-Final3/14/20143/14/20143/14/2014 2:14:49 PMPPART
Ron Ramza-PLease call at least 30 mins prior to inspection Phone #: ###-#### pending fire/ rackibng permit if over height 12 ft after fire c/n
BLD13-02316 BLD-Final3/12/20143/14/20143/14/2014 11:42:58 AMAPASS
Bob Phone #: ###-####
BLD13-02316 DOC - Permit Finaled3/14/20143/14/20143/14/2014 11:40:35 AMPPASS
BLD13-03145 BLD-Final3/12/20143/14/20143/14/2014 11:39:22 AMAPASS
Bob Phone #: ###-####
BLD13-03145 DOC - Permit Finaled3/14/20143/14/20143/14/2014 11:39:00 AMPPASS
BLD14-00078 BLD-Final3/12/20143/14/20143/14/2014 11:38:11 AMAPASS
Bob Phone #: ###-####
BLD14-00078 DOC - Permit Finaled3/14/20143/14/20143/14/2014 11:37:40 AMPPASS
BLD14-00078 DOC - Permit Finaled3/14/20143/14/20143/14/2014 11:37:05 AMPPASS
BLD13-02706 BLD-Final3/12/20143/14/20143/14/2014 11:36:14 AMAPASS
Bob Phone #: ###-####
BLD14-00104 BLD-Framing/Rough-in3/13/20143/14/20143/14/2014 10:42:34 AMAPASS
kent - late morning - please call 1/2 hr prior Phone #: ###-####
BLD13-02011 BLD-Energy code compliance3/11/20143/14/20143/14/2014 10:10:19 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Clint Wall
MIS14-00042 BLD-Conference3/13/20143/14/20143/14/2014 9:44:37 AMAPASS
Mike Phone #: ###-#### 9-930 appt 301 hardware/glazing at office door 24 inches/ ele clean up