Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM16-00885 Final3/14/20163/14/20163/14/2016 4:32:54 PMPPASS
Please call MICHAEL ###-#### when on way
Phone #: ###-#### Inspection requested via web by Ben Davis
>wh/co ok
PLM16-00886 Groundwork3/14/20163/14/20163/14/2016 4:09:33 PMPPASS
Phone #: ###-#### Inspection requested via web by Craig Johnson
>cover pipe with clean fill then ok
PLM16-00891 Final3/14/20163/14/20163/14/2016 3:44:36 PMPFAIL
Main contact is Patrick Murray please call him prior to arrival at ###-####. Phone #: ###-#### Inspection requested via web by Maira Guzman
>pvc hose connections not approved material
>RP cannot be located inside wall cavity behind access panel.
PLM16-00892 DOC - Permit Finaled3/14/20163/14/20163/14/2016 3:03:46 PMPPASS
PLM16-00892 Water and/or Sewer3/14/20163/14/20163/14/2016 3:03:25 PMPPASS
John Phone #: ###-####
PLM16-00164 Groundwork3/14/20163/14/20163/14/2016 2:33:17 PMPPASS
MIKE IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER
>shell sewer/grease and water gw ok
PLM16-00598 Plumbing Rough-in3/13/20163/14/20163/14/2016 1:55:59 PMPFAIL
JOB # 13697. Phone #: ###-#### Inspection requested via web by Ann Marie Reyes
>K/S trap arm is backgraded
>T/S combo trap arm to side inlet is bowed
>missing strap on 2" in crawl from washer box
PLM16-00717 Plumbing Rough-in3/13/20163/14/20163/14/2016 1:54:23 PMPPASS
JOB # 13710 Phone #: ###-#### Inspection requested via web by Ann Marie Reyes
PLM16-00866 DOC - Permit Finaled3/14/20163/14/20163/14/2016 1:28:22 PMPPASS
PLM16-00866 Water and/or Sewer3/14/20163/14/20163/14/2016 1:28:02 PMPPASS
Larry Phone #: ###-####
PLM16-00812 Water and/or Sewer3/14/20163/14/20163/14/2016 11:20:54 AMPCANC
Please Call Dave Prior To Inspection ###-#### Phone #: ###-#### Inspection requested via web by DANIELLE BROOKSHIRE
>inspection canceled by Dave. just a repair. no permitted needed
PLM16-00864 Final3/11/20163/14/20163/14/2016 11:19:24 AMAPASS
please call prior to arrival ###-#### Phone #: ###-#### Inspection requested via web by James Staley
>wh ok
PLM16-00680 Plumbing Rough-in3/11/20163/14/20163/14/2016 10:47:47 AMAFAIL
Sharon Phone #: ###-####
>need to put all new work under 5 psi test or fill with water to top of vent
>santee not an aprroved horizontal ftg, change out to wye ftg
PLM16-00536 Water and/or Sewer3/11/20163/14/20163/14/2016 10:17:42 AMANR
KEITH IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER
>no inspection needed per Keith
PLM16-00858 Final3/11/20163/14/20163/14/2016 9:10:39 AMAFAIL
Please call Skip at ###-#### before arriving, thank you. Inspection requested via web by TERESA HUTTO
>flex connector is not approved piping on a t&p from water heater. replace with approved piping and send a picture to final permit.
PLM16-00761 Plumbing Rough-in3/11/20163/14/20163/14/2016 8:45:40 AMAFAIL
Jacqueline Phone #: ###-####
>both cleanouts at sinks leaking, fix and retest
PLM16-00828 Plumbing Rough-in3/11/20163/14/20163/14/2016 8:03:13 AMACANC
Sean Phone #: ###-####
>inspected on friday 3/11/16
PLM15-02482 PLM-Aging Inspection3/14/20163/14/20163/14/2016 7:59:12 AM FAIL
no request, contractor can send picture of correction if done to final out permit.