MEC18-01169
| Pressure Test | 3/13/2018 | 3/14/2018 | 3/14/2018 4:01:34 PM | P | FAIL |
|
|
PM. Please call when on way. Gener ###-####. Phone #: ###-#### Inspection requested via web by Krista Boss- gauge wont zero out
|
MEC18-01126
| Final | 3/14/2018 | 3/14/2018 | 3/14/2018 3:39:55 PM | P | PASS |
|
|
If you could please call Bob H when heading over. Thank you! ###-#### Phone #: ###-#### Inspection requested via web by Ron Arnold
|
MEC18-01133
| Rough-in | 3/14/2018 | 3/14/2018 | 3/14/2018 3:07:04 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart- all exhaust fans need taped/sealed where ties onto fan- b vent at roof level furnace location needs 1" clearance to combustibles and pipe secured- corretion notice front window
|
MEC18-01134
| Rough-in | 3/14/2018 | 3/14/2018 | 3/14/2018 3:05:17 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart- fireplace R/I ok
|
MEC18-01107
| Rough-in | 3/14/2018 | 3/14/2018 | 3/14/2018 2:46:39 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart- correction on fireplace not made
|
MEC18-01081
| Final | 3/14/2018 | 3/14/2018 | 3/14/2018 2:30:13 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Melissa Skinner- final ok
|
MEC18-00674
| Rough-in | 3/14/2018 | 3/14/2018 | 3/14/2018 1:43:38 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Krista Boss- need approved ACCA report onsite for inspection- need right address on housing before next inspection
|
MEC18-01030
| Rough-in | 3/14/2018 | 3/14/2018 | 3/14/2018 11:45:10 AM | A | PASS |
|
|
R/I ok- fireplace R/I ok
|
MEC18-01030
| Rough-in | 3/14/2018 | 3/14/2018 | 3/14/2018 11:44:36 AM | A | PASS |
|
|
fireplace R/I ok
|
MEC18-01137
| Final | 3/13/2018 | 3/14/2018 | 3/14/2018 11:16:52 AM | A | PASS |
|
|
homeowner 2083423443- Kevin 2089413166- furnace coil ac co ok
|
MEC17-00553
| Final | 3/14/2018 | 3/14/2018 | 3/14/2018 11:02:23 AM | A | PASS |
|
|
mini split ok
|
MEC18-01171
| Rough-in | 3/13/2018 | 3/14/2018 | 3/14/2018 10:41:21 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by jeff jedlick- R/I ok- ok for cover
|
MEC18-01171
| Pressure Test | 3/14/2018 | 3/14/2018 | 3/14/2018 10:40:37 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by jeff jedlick- 20lb gas pass
|
MEC18-01172
| Rough-in | 3/13/2018 | 3/14/2018 | 3/14/2018 10:18:19 AM | A | FAIL |
|
|
Call before going to make sure someone it there for you Phone #: ###-#### Inspection requested via web by Rene Neumeyer- appliance gas connector can not run thru appliance- need csst piping with protective sleeve or hard pipe ran to appliance
|
MEC18-00943
| Final | 3/13/2018 | 3/14/2018 | 3/14/2018 9:46:04 AM | A | PASS |
|
|
call 1/2 hr before // Mike Phone #: ###-####- 5lb flue pass- furnace ac co ok
|
MEC17-00553
| Mec-Aging Inspection | 3/14/2018 | 3/14/2018 | 3/14/2018 9:26:16 AM | | PEND |
|
|
contractor will schedule final per phone call
|
MEC17-05466
| Final | 3/13/2018 | 3/14/2018 | 3/14/2018 9:17:11 AM | A | PASS |
|
|
call clint at ###-#### for access info Inspection requested via web by Don Dowers- 20lb gas was passed and tagged on roughin- wasnt noted- Final ok
|
MEC18-01030
| Conference | 3/13/2018 | 3/14/2018 | 3/14/2018 8:50:02 AM | A | DONE |
|
|
8:00 - 8:30 - RJ Phone #: ###-#### Inspection requested via web by Brandon Sorensen- went over issues with installer- talked about fireplace install b vent insulation shield nail plates and other misc stuff
|
MEC17-01708
| Mec-Aging Inspection | 3/14/2018 | 3/14/2018 | 3/14/2018 8:06:32 AM | | DONE |
|
|
|
MEC17-01708
| Final | 3/14/2018 | 3/14/2018 | 3/14/2018 8:06:22 AM | A | PASS |
|
|
should have been finaled out on first inspection
|
MEC17-03052
| Mec-Aging Inspection | 3/14/2018 | 3/14/2018 | 3/14/2018 8:03:44 AM | | DONE |
|
|
|
MEC17-03052
| Final | 3/14/2018 | 3/14/2018 | 3/14/2018 8:03:32 AM | A | PASS |
|
|
final ok- electrical permit pulled and inspected
|
MEC18-01137
| Final | 3/12/2018 | 3/14/2018 | 3/13/2018 4:25:02 PM | A | CANC |
|
|
contact homeowner ###-#### or Kevin (QHC) @ Phone #: ###-#### Inspection requested via web by Kevin Pratley- fail by accident- rescheduled for tomorrow AM
|