Inspections for the day of: Thursday, March 15, 2018.
Number of inspections: 18
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorDan Ediger
TitlePLM-INSPECTOR
Phone #869-5166
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM18-00938 Plumbing Rough-in3/14/20183/15/20183/15/2018 4:45:48 PMPPASS
Phone #: ###-#### Inspection requested via web by Branden Steers
PLM18-01050 Plumbing Rough-in3/14/20183/15/20183/15/2018 3:36:13 PMPPASS
Plz call Michael Pishl at 208 401 5551 to gain access to property 30 minutes b4 you arrive Phone #: ###-#### Inspection requested via web by Scott Myers
PLM17-04812 Plumbing Rough-in3/15/20183/15/20183/15/2018 3:01:40 PMPPASS
Phone #: ###-#### Inspection requested via web by David Scaggs
PLM18-01060 Water and/or Sewer3/15/20183/15/20183/15/2018 2:38:17 PMPPASS
Phone #: ###-#### Inspection requested via web by GENE KING
PLM18-01060 DOC - Permit Finaled3/15/20183/15/20183/15/2018 2:38:04 PMPPASS
PLM18-01053 Water and/or Sewer3/14/20183/15/20183/15/2018 2:08:18 PMPPASS
Thursday afternoon please inspect water line installation. Contact is Luke Karel. Phone #: ###-#### Inspection requested via web by Luke Karel
PLM18-01053 DOC - Permit Finaled3/15/20183/15/20183/15/2018 2:08:08 PMPPASS
PLM18-01006 Final3/14/20183/15/20183/15/2018 12:30:04 PMAFAIL
Phone #: ###-#### Inspection requested via web by PATTY KIRK.
1. Install open front less lid wc seats-all.
2. Install tempering valves on all public faucets or one at the water heater.
3. Certify all backflow assemblies.
4. The womans ada water closet requires a right hand flush tank.
MIS18-00083 PLM-Final3/13/20183/15/20183/15/2018 11:58:23 AMANR
NIcholas Phone #: ###-#### for restaurant occupancy
MIS18-00084 PLM-Final3/13/20183/15/20183/15/2018 11:58:05 AMAFAIL
NIcholas Phone #: ###-#### for restaurant occupancy
The double check and rp are run in series.
1. The carbonator must have a dedicated rp backflow assembly.
2. The ice tea machine must be served by a rp backflow assembly.
3. Install airgaps on both rp's and pipe to the floor sink.
4. Support the backflow assemblies on the outlet side.
5. The plumber must pull a permit and schedule an inspection.
6. If the ice maker has a pre-filter installed then it must be protected by a double check.
PLM18-01051 Final3/15/20183/15/20183/15/2018 11:48:36 AMAPASS
20#
PLM17-04851 Final3/14/20183/15/20183/15/2018 9:39:49 AMACANC
if questions call Ryan @ ###-####. Phone #: ###-#### Inspection requested via web by Stacia Haumann
passed as a rough in
PLM17-04851 Plumbing Rough-in3/15/20183/15/20183/15/2018 9:38:34 AMAPASS
if questions call Ryan @ ###-####. Phone #: ###-#### Inspection requested via web by Stacia Haumann. water and waste
PLM18-01051 Pressure Test3/14/20183/15/20183/15/2018 9:19:47 AMAFAIL
Call me when completed plz Phone #: ###-#### Inspection requested via web by Scott Myers.
Defective gauge
PLM18-00937 Plumbing Rough-in3/14/20183/15/20183/15/2018 9:00:53 AMAPASS
Phone #: ###-#### Inspection requested via web by Branden Steers
PLM17-03804 Plumbing Rough-in3/14/20183/15/20183/15/2018 8:40:52 AMAPASS
Kevin Phone #: ###-#### passed as final
PLM17-03804 DOC - Permit Finaled3/15/20183/15/20183/15/2018 8:40:32 AMPPASS
PLM16-04200 PLM-Aging Inspection3/15/20183/15/20183/15/2018 8:19:26 AM PEND
wip