Inspections for the day of: Wednesday, March 16, 2005.
Number of inspections: 8
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE04-02639 Electrical Rough-In3/15/20053/16/20053/16/2005 12:00:00 AMAPART
Scheduled by a contractor via Hello! on 3/15/2005 at 8:44:25 AM. Contact: ###-####. Mainly job walk to get familiar with job, pointed out foreign piping over elect equip in elect room, signed their inspection log 3/16/2005 9:53:53 AM
ELE05-00655 Final3/15/20053/16/20053/16/2005 12:00:00 AMACANC
cHRIS; Phone #: ###-#### Internet Inspection Request from: Jan Rice see added insp. this for r/i 3/16/2005 10:16:10 AM
ELE05-00777 Final3/15/20053/16/20053/16/2005 12:00:00 AMAPASS
reinspection on hot tub Internet Inspection Request from: Andy Rose corrections made, ok to final 3/16/2005 8:00:05 AM
ELE05-00332 Final3/15/20053/16/20053/16/2005 12:00:00 AMAPASS
calvin; Phone #: ###-#### Internet Inspection Request from: Barbara Moore ok to final 3/16/2005 8:36:14 AM
ELE05-00655 Rough-In Permanent Service3/16/20053/16/20053/16/2005 12:00:00 AMAPASS
corrections made, left survey for staple romex. ric ok, p/s u/g n ok
ELE05-00659 Electrical Rough-In3/16/20053/16/20053/16/2005 12:00:00 AMPPART
TOBY CEILING COVER; Phone #: ###-#### Internet Inspection Request from: Sean DeLacy Clg cover ok north 1/2 and borders ok. Not front windows. Need to add show room recpts. 3/16/2005 12:36:27 PM
ELE05-00864 Final3/15/20053/16/20053/16/2005 12:00:00 AMPPASS
thank you.; Phone #: ###-#### Internet Inspection Request from: BRIAN KEITH ok to final 3/16/2005 4:33:07 PM
ELE05-00842 Electrical Rough-In3/16/20053/16/20053/16/2005 12:00:00 AMPFAIL
greg; Phone #: ###-#### Internet Inspection Request from: Barbara Moore 314.23(C) rear outside light box shall be securely fastened, 334.80 ampacity of more than 2 nm cables shall be adjusted over panel,300.4(D) cable shall be 1 1/4" from edge of framing member, 314.17(A) boxes shall be replaced where openings knocked out, 210.52(A) recpt shall be installed by front door into living room,BCC all boxes shall be made up, called contr , left corr notice 3/16/2005 2:50:09 PM