Inspections for the day of: Friday, March 17, 2006.
Number of inspections: 17
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE05-01707 ELE-Aging Inspection3/17/20063/17/20063/20/2006 3:09:32 PM NR
contr still needs parts
ELE04-01948 ELE-Aging Inspection3/17/20063/17/20063/20/2006 10:03:55 AM DONE
waiting for contr to call
ELE05-01924 Final3/17/20063/17/20063/17/2006 4:36:16 PMPPASS
ok to final, looked at sign
ELE05-01924 ELE-Aging Inspection3/17/20063/17/20063/17/2006 4:35:09 PM DONE
see final
ELE06-00801 Rough-In Permanent Service3/17/20063/17/20063/17/2006 4:32:04 PMPPASS
Brandon -- reinspection; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong corr made, ric ok
ELE06-00318 Final3/17/20063/17/20063/17/2006 3:58:21 PMPPASS
did inspection, ok to final
ELE05-03886 Final3/17/20063/17/20063/17/2006 3:57:18 PMPPASS
contr made corrections, called to see if we could re-inspect. ok to final, signed occ card
ELE05-02222 Final3/16/20063/17/20063/17/2006 3:17:10 PMPPASS
NEED FINAL ON HOT TUB. WILL LEAVE NORTH GATE OPEN, PLEASE MAKE SURE ITS CLOSED AFTER. THANK YOU.; Phone #: ###-#### Internet Inspection Request from: BRIAN KEITH ok to final
ELE06-00586 Final3/17/20063/17/20063/17/2006 2:45:29 PMPPASS
ok to final, met with owner
ELE05-02421 Final3/17/20063/17/20063/17/2006 2:18:46 PMPPASS
Ed; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong corr made, ok to final
ELE05-03886 Final3/17/20063/17/20063/17/2006 12:59:20 PMPFAIL
met with 315 and contr, corr not done, they will call for Mon am
ELE06-00912 Final3/16/20063/17/20063/17/2006 10:42:25 AMAPASS
Please call half an hour before you perform the inspection; Phone #: ###-#### Internet Inspection Request from: Dana Moyer called contr to label panel, ok to final
ELE05-03467 Final3/16/20063/17/20063/17/2006 10:07:05 AMAFAIL
Phone #: ###-#### Internet Inspection Request from: Dana Moyer called contr, wrong number, called another number, left corr notice,410.8(C)&(D) open incandescent fixtures shall not be used in closets and clearances shall be provided,406.4(D) receptacle faces shall be flush or project from faceplates, 408.4 circuit directories shall be complete and evident for specific use, 680.26(B)(5) metal within 5' of hot tub shall be bonded,406(B) receptacles in wet locations shall have in-use covers, 410.4 shall install fixture out back suitable for wet location
ELE06-00212 Final3/16/20063/17/20063/17/2006 9:28:42 AMAPASS
paul; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa ok to final
ELE06-00714 Electrical Rough-In3/16/20063/17/20063/17/2006 9:00:11 AMAPASS
garage code is 5991 then hit enter I should be there by 8:30 thank ; Phone #: ###-#### Internet Inspection Request from: steven sewell ric ok
ELE04-03436 Final3/16/20063/17/20063/17/2006 8:19:54 AMAPASS
NEED FINAL INSPECTION ON HOT TUB INSTALLATION. THANK YOU.; Phone #: ###-#### Internet Inspection Request from: BRIAN KEITH ok to final
ELE06-00113 Electrical Rough-In3/10/20063/17/20063/16/2006 11:15:19 AMACANC
CONTACT: LYLE DEAN - ROUGH IN INSPECTION 6TH FLOOR; Phone #: ###-#### Internet Inspection Request from: Deb McCoy Inspection cancelled from web by: Deb McCoy