ESC09-00016
| General Inspection | 3/17/2009 | 3/17/2009 | 3/17/2009 2:58:30 PM | P | PASS |
|
|
site ok
|
ELE09-00413
| Electrical Rough-In | 3/16/2009 | 3/17/2009 | 3/17/2009 2:57:38 PM | P | FAIL |
|
|
lars - please call ahead for access Phone #: ###-#### called corr do not cover posted 210.52(A) needs outlet wall space fam. rm. 314.16 box fill 2 bed rms upstairs, and din. rm. 210.52(B) remove range hood from kit. SABC, 314.20 all outside boxes shall be flush with siding at time of r/i, 334.23 protect cables within 6ft of attic access, 250.148 splice all equip. grds together 2 gang left of kit. sink, 110.3(A) shall provide 16"x20" access for j tub equip per manufacture's instructions at time of r/i, j tub listing ok
|
ESC09-00072
| General Inspection | 3/17/2009 | 3/17/2009 | 3/17/2009 1:22:15 PM | P | PART |
|
|
ok needs some clean up will stop back
|
ELE09-00435
| Electrical Rough-In | 3/17/2009 | 3/17/2009 | 3/17/2009 1:20:46 PM | P | PASS |
|
|
Tomas Phone #: ###-#### ok
|
ELE09-00435
| Permanent Service | 3/17/2009 | 3/17/2009 | 3/17/2009 1:20:39 PM | P | PASS |
|
|
Tomas Phone #: ###-#### p/s u/g new ok
|
ESC03-01262
| DOC - Permit Expired | 3/17/2009 | 3/17/2009 | 3/17/2009 10:32:12 AM | A | PASS |
|
|
|
ESC03-01264
| DOC - Permit Expired | 3/17/2009 | 3/17/2009 | 3/17/2009 10:31:40 AM | A | PASS |
|
|
|
ESC03-01263
| DOC - Permit Expired | 3/17/2009 | 3/17/2009 | 3/17/2009 10:31:04 AM | A | PASS |
|
|
|
ESC03-00936
| DOC - Permit Expired | 3/17/2009 | 3/17/2009 | 3/17/2009 10:30:24 AM | A | PASS |
|
|
|
ELE09-00426
| Electrical Rough-In | 3/16/2009 | 3/17/2009 | 3/17/2009 9:45:32 AM | A | PART |
|
|
Shawn ###-#### west and back walls ok only, called needs to secure MC 12" at panel
|
ELE08-03297
| Final | 3/16/2009 | 3/17/2009 | 3/17/2009 9:07:54 AM | A | FAIL |
|
|
Please call for access code ###-#### Phone #: ###-#### Internet Inspection Request from: Rhonda Yoast corr. called 110.3(A) install all plates, fixture trims, and ironing board, 210.52(C)(1) needs recept within 24" right of range, 406.4 front porch recept loose, 410.2&16 clearence for MB closet fixture
|
ESC08-00974
| General Inspection | 3/17/2009 | 3/17/2009 | 3/17/2009 9:04:48 AM | A | PASS |
|
|
site ok
|