Inspections for the day of: Thursday, March 17, 2016.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE12-02548 ELE-Aging Inspection3/17/20163/17/20163/18/2016 2:59:06 PM PASS
Waiting on contractor
ELE16-00560 Electrical Rough-In3/16/20163/17/20163/17/2016 3:20:59 PMPPASS
Phone #: ###-#### Inspection requested via web by Stacie Tasker
Parking lot underground complete. Rough in ok cover
ELE15-03853 Final3/17/20163/17/20163/17/2016 2:48:46 PMPFAIL
Builder will have residence unlocked. Builder is Damion at ###-#### Phone #: ###-#### Inspection requested via web by Paula Gratiot
210.12- All 120 volt outlets located in bedrooms shall have AFCI protection. Smokes.
210.23- If microwave is in place installation will determine circuitry. Contactor stated space is for storage only. 1.2 KW micro on site.
210.52(C)(1)- A receptacle outlet shall be installed with in 24" of edge of counter top.
210.52(C)(3)- A receptacle outlet shall be installed at end of peninsula to serve counter space.
230.28- Service extends 5' above roof, secure guy kit that is installed.
314.23- AC disconnect shall be secured to surface of wall and cover secured.
ELE16-00552 Final3/16/20163/17/20163/17/2016 2:39:19 PMPPASS
Please call Matt ###-#### when you are on your way. Thank You. Phone #: ###-#### Inspection requested via web by Clay Morgan Final ok
ELE16-00860 Electrical Rough-In3/17/20163/17/20163/17/2016 1:36:37 PMPPASS
call 1/2 hr prior Phone #: ###-#### Inspection requested via web by MIKE HAGERTY Up master bath remodel. Informed owner minimum required receptacles for basins shall not be located in cabinets. Bath walls, hardlid, and floor heat rough in ok cover
ELE15-04039 Electrical Rough-In3/17/20163/17/20163/17/2016 1:08:55 PMPPASS
Contact: Clay Freinwald - ceiling inspection please Phone #: ###-#### Inspection requested via web by Deb Gooden
Couple covers missing, south hall west side, north bath facing up, N.W. corner by door. Will check on final. Grid rough in ok cover
ELE16-00307 Final3/16/20163/17/20163/17/2016 10:41:35 AMAPASS
Phone #: ###-#### Inspection requested via web by Jim Williams Final ok
ELE15-00649 Final3/15/20163/17/20163/17/2016 10:11:09 AMANH
Jason Phone #: ###-####
No answer at door, called and left message
ELE15-02489 Electrical Rough-In3/16/20163/17/20163/17/2016 9:55:54 AMAPASS
Rough in inspection Phone #: ###-#### Inspection requested via web by Spencer McLean
3 Massage or therapy rooms rough in ok cover
ELE16-00425 Electrical Rough-In3/16/20163/17/20163/17/2016 9:27:15 AMAPASS
Kitchen cover inspection, please call when headed my way, I''ll be waiting. Thanks. Richard ###-#### Phone #: ###-#### Inspection requested via web by Richard Corn
corrections complete. kitchen remodel rough in ok cover
ELE16-00840 Temporary Service3/16/20163/17/20163/17/2016 8:51:06 AMAPASS
Phone #: ###-#### Inspection requested via web by Therrin Robertson
t/s u/g n ok
ELE16-01838 Electrical Rough-In3/16/20163/17/20163/17/2016 12:00:00 AMAPASS
Level 2, Stack 2

Rms 245, 251, 252, 253, 247, 248, 249, 250, 242, Janitor, Bathrooms core Phone #: ###-#### Inspection requested via web by Tom Betty r/i walls ok areas listed above. Also looked at fixtures in Fantony ceiling system. 277 volt and 0-10 MA for controlling fixtures. 0-10 MA conductors have 600 volt rating and is ok to make connections in same jbox as 277volt source.