MEC20-01116
| Final | 3/17/2020 | 3/17/2020 | 3/17/2020 3:50:05 PM | P | PASS |
|
|
Call Mato''s prior to arrival to ensure ready. Phone #: ###-#### Inspection requested via web by Andrea Grigsby- furnace a/c coil co locking caps ok- 5lb flue pass
|
MEC20-01120
| Final | 3/17/2020 | 3/17/2020 | 3/17/2020 3:36:39 PM | P | PART |
|
|
Phone #: ###-#### Inspection requested via web by Brandon Sorensen- need plenum rated material for drain off ceiling mini split no pvc allowed- need protection on lineset on roof bare copper showing- mini split mc cable does not meet amp rating- talked with GC, electrician and service tech onsite- should have been a R/I inspection on this before final was called in
|
MEC20-00475
| Rough-in | 3/16/2020 | 3/17/2020 | 3/17/2020 2:37:06 PM | P | PASS |
|
|
Field super: Daryl Thomas Phone #: ###-#### Inspection requested via web by Lisa Whitney
|
MEC20-00475
| Pressure Test | 3/16/2020 | 3/17/2020 | 3/17/2020 2:36:45 PM | P | PASS |
|
|
Field super: Daryl Thomas Phone #: ###-#### Inspection requested via web by Lisa Whitney- 20lb gas pass tagged meter location
|
MEC20-00897
| Final | 3/17/2020 | 3/17/2020 | 3/17/2020 2:00:44 PM | P | PASS |
|
|
final ok
|
MEC20-00600
| Final | 3/17/2020 | 3/17/2020 | 3/17/2020 1:12:28 PM | P | PASS |
|
|
furnace only co ok
|
MEC20-00424
| Final | 3/17/2020 | 3/17/2020 | 3/17/2020 1:01:42 PM | P | PASS |
|
|
If questions call Chad @ ###-#### Phone #: ###-#### Inspection requested via web by Stacia Haumann- final ok- RTU only unit heater remaining in original location
|
MEC19-05181
| Final | 3/16/2020 | 3/17/2020 | 3/17/2020 12:17:00 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart- final ok- no a/c installed was exhaust fan, range hood and supply ducting
|
MEC20-01117
| Rough-in | 3/17/2020 | 3/17/2020 | 3/17/2020 11:26:10 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by JOSE DUARTE- R/I ok
|
MEC20-01117
| Pressure Test | 3/17/2020 | 3/17/2020 | 3/17/2020 11:25:53 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by JOSE DUARTE- 20lb gas pass tagged meter location
|
MEC20-01118
| Rough-in | 3/17/2020 | 3/17/2020 | 3/17/2020 11:14:44 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by JOSE DUARTE- R/I ok
|
MEC20-01118
| Pressure Test | 3/17/2020 | 3/17/2020 | 3/17/2020 11:14:30 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by JOSE DUARTE- 20lb gas pass tagged meter location- 5lb flue pass
|
MEC20-01113
| Rough-in | 3/16/2020 | 3/17/2020 | 3/17/2020 10:49:05 AM | A | PART |
|
|
Mechanical Cover Inspection needed for Children''s Therapy. Please contact Mike Desimone with any questions ###-#### Thank you. Phone #: ###-#### Inspection requested via web by Karl Hestekin- approved drawings onsite- seal on misc ducts ok marked with x on contractors print- ok to insulate these ducts only- will look at remainder on next inspection- seal on exhaust duct above bathroom and janitor closet ok- ok for cover hard lids only
|
MEC20-01113
| Conference | 3/16/2020 | 3/17/2020 | 3/17/2020 10:46:34 AM | A | CANC |
|
|
Mechanical Duct Seal Inspection needed for Children''s Therapy. Please contact Mike Desimone with any questions ###-#### Thank you. Phone #: ###-#### Inspection requested via web by Karl Hestekin- no conference needed was R/I
|
MEC20-00892
| Rough-in | 3/16/2020 | 3/17/2020 | 3/17/2020 9:35:40 AM | A | CANC |
|
|
C/I. Please contact Robbie prior to arrival - ###-#### Phone #: ###-#### >> Inspection requested via web by Commercial Coordinator Inspection cancelled from web by: Commercial Coordinator
|
MEC20-00976
| Final | 3/12/2020 | 3/17/2020 | 3/17/2020 9:25:22 AM | A | FAIL |
|
|
call barbara when on the way ###-#### Phone #: ###-#### Inspection requested via web by Lindsey Stegemann- pellet stove doesnt meet minimun 7" to wall per installation instructions- flue outside at top needs 1" clearance to siding
|
MEC20-00860
| Final | 3/10/2020 | 3/17/2020 | 3/17/2020 9:15:03 AM | A | PASS |
|
|
Please call Leslye Moore prior to inspection. ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette- furnace a/c coil co locking caps ok
|
MEC20-01116
| Pressure Test | 3/16/2020 | 3/17/2020 | 3/17/2020 9:03:33 AM | A | CANC |
|
|
Please call Chris Mato''s prior to arrival to ensure ready. Phone #: ###-#### Inspection requested via web by Andrea Grigsby- will complete in afternoon per Josh text
|
MEC20-01018
| Final | 3/16/2020 | 3/17/2020 | 3/17/2020 8:38:18 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by max sanders- final ok card signed
|
MEC20-01018
| Rough-in | 3/17/2020 | 3/17/2020 | 3/17/2020 8:37:26 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by max sanders- misc supply, return and transfer grills, flex and insulation ok
|
MEC20-01081
| Rough-in | 3/16/2020 | 3/17/2020 | 3/17/2020 8:17:22 AM | A | PASS |
|
|
CHRISTINA ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza- fireplace R/I ok
|
MEC20-00277
| Rough-in | 3/16/2020 | 3/17/2020 | 3/16/2020 7:29:41 PM | A | CANC |
|
|
>> Inspection requested via web by GREGORY ANDERSEN Inspection cancelled from web by: GREGORY ANDERSEN
|