ELE05-00494
| Electrical Rough-In | 3/15/2005 | 3/18/2005 | 3/18/2005 12:00:00 AM | A | PASS |
|
|
rough in Internet Inspection Request from: Andy Rose ok 3/18/2005 8:24:59 AM
|
ELE05-00718
| Electrical Rough-In | 3/16/2005 | 3/18/2005 | 3/18/2005 12:00:00 AM | A | PART |
|
|
underground conduit Internet Inspection Request from: Lee VanSchoiack ###-#### u/g ok called about new bonding 3 ft out 680.26(C) 3/18/2005 9:00:51 AM
|
ELE05-00746
| Electrical Rough-In | 3/17/2005 | 3/18/2005 | 3/18/2005 12:00:00 AM | A | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Heather Packer ok 3/18/2005 9:32:08 AM
|
ELE05-00895
| Temporary Service | 3/17/2005 | 3/18/2005 | 3/18/2005 12:00:00 AM | A | PASS |
|
|
aaron ###-#### t/s o/h new ok 3/18/2005 8:03:05 AM
|
ELE03-03159
| Final | 3/17/2005 | 3/18/2005 | 3/18/2005 12:00:00 AM | P | FAIL |
|
|
Scheduled by a contractor via Hello! on 3/17/2005 at 8:56:36 PM. Contact: ###-####. job is a mess owner had someone else do work permit for p/s and 2rooms he rewired almost all of the house, kit wiring not right , bath 20 amp has bedrm and garage on it wall spacing open grds, wires just twisted together in boxes screws in plastic boxes wired cover and no inspection 3/18/2005 3:27:15 PM
|
ELE05-00831
| Final | 3/18/2005 | 3/18/2005 | 3/18/2005 12:00:00 AM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 3/18/2005 at 8:03:06 AM. Contact: ###-####. ok 3/18/2005 4:01:38 PM
|
ELE05-00892
| Final | 3/18/2005 | 3/18/2005 | 3/18/2005 12:00:00 AM | P | FAIL |
|
|
Scheduled by a contractor via Hello! on 3/18/2005 at 9:13:06 AM. Contact: ###-####. needs #6 or protect #8 GEC this is in hiawatha by address10878 called 3/18/2005 1:16:23 PM
|
ELE05-00901
| Temporary Service | 3/18/2005 | 3/18/2005 | 3/18/2005 12:00:00 AM | P | FAIL |
|
|
set back off road and about 100 feet north of targee on the east side of road mike ###-#### gfci for 220 V recept, brace or guy pole for t/s for support cor. posted called 3/18/2005 12:43:42 PM
|
ELE04-03213
| Final | 3/18/2005 | 3/18/2005 | 3/18/2005 12:00:00 AM | P | PASS |
|
|
clyde; Phone #: ###-#### Internet Inspection Request from: Barbara Moore ok survey needs bond bushing on end of offset nipple where RE washers are used 3/18/2005 3:22:40 PM
|
ELE05-00380
| Final | 3/17/2005 | 3/18/2005 | 3/18/2005 12:00:00 AM | P | FAIL |
|
|
BJ; Phone #: ###-#### Internet Inspection Request from: Jan Rice p/s not ready grds not complete, 3/18/2005 2:16:07 PM
|
ELE05-00866
| Permanent Service | 3/17/2005 | 3/18/2005 | 3/18/2005 12:00:00 AM | P | FAIL |
|
|
Internet Inspection Request from: Lee VanSchoiack cor. posted called 300.3 all wire and cables shall have same voltage rating when mixes together, needs 2 grd rods, 300.4 1 1/4 inches for cables, 300.10 needs bond bushings for RE washers 3/18/2005 1:47:58 PM
|