Inspections for the day of: Friday, March 19, 2004.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRick Jackson
TitleFIRE INSPECTOR
Phone #794-1981
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
FIR03-00542 INSP-Final Inspection3/18/20043/19/20043/19/2004 12:00:00 AMAPASS
Scheduled by a contractor via Hello! on 3/18/2004 at 12:48:13 PM. Contact: ###-####.
FIR03-00305 INSP-Sprinkler Rough-in/Hydro3/18/20043/19/20043/19/2004 12:00:00 AMAPASS
Tom ###-#### okay to cover; additional heads added at lobby due to finished ceiling height; will close this out final inspection to verify escutcheons 3/19/2004 10:15:27 AM
FIR04-00141 INSP-Sprinkler Rough-in3/18/20043/19/20043/19/2004 12:00:00 AMANR
This is a cover inspection - contact mike -- would like at 12 noon.; Phone #: ###-#### Internet Inspection Request from: Alicia Pauley Not ready; they will reschedule for 3/22/04 3/19/2004 1:39:41 PM
FIR04-00075 INSP-Final Inspection3/18/20043/19/20043/19/2004 12:00:00 AMAFAIL
Warner; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes batteries not supervised; in-room detector sets off main alarms - not per plans; additional power supply not shown on plans 3/19/2004 11:02:23 AM
BLD03-02812 FIRE-Final Inspection3/16/20043/19/20043/19/2004 12:00:00 AMAFAIL
###-#### Jim,; Phone #: ###-#### Internet Inspection Request from: Annette Moore need key lock both side at main exit with lever type; extinguisher needed; sign above door to remain unlocked; threshold and landings need to comply with notes 15-16 3/19/2004 11:04:34 AM
FIR04-00159 INSP-Final Inspection3/17/20043/19/20043/19/2004 12:00:00 AMPPASS
###-#### darrin
BLD03-02799 FIRE-Final Inspection3/19/20043/19/20043/19/2004 12:00:00 AMPPASS
Bob ; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes turn around installed 3/19/2004 3:12:48 PM
FIR04-00075 INSP-Final Inspection3/19/20043/19/20043/19/2004 12:00:00 AMPPASS
Warner --- please call first; Phone #: ###-#### Internet Inspection Request from: Aimee Hughes
FIR04-00065 INSP-Final Inspection3/19/20043/19/20043/19/2004 12:00:00 AMPPASS
BLD03-01122 FIRE-Final Inspection3/19/20043/19/20043/19/2004 12:00:00 AMPPASS
FIR04-00139 INSP-Sprinkler Rough-in3/19/20043/19/20043/19/2004 12:00:00 AMPPART
okay to cover front lobby area 3/19/2004 3:27:01 PM
FIR03-00736 INSP-Final Inspection3/19/20043/19/20043/19/2004 12:00:00 AMPPASS
FIR03-00761 INSP-Final Inspection3/19/20043/19/20043/19/2004 12:00:00 AMPPASS
BLD02-03085 FIRE-Final Inspection3/19/20043/19/20043/19/2004 12:00:00 AMPPASS
BLD03-00498 FIRE-Final Inspection3/19/20043/19/20043/19/2004 12:00:00 AMPPASS