ELE07-00465
| Electrical Rough-In | 3/19/2007 | 3/19/2007 | 3/19/2007 2:31:49 PM | P | PASS |
|
|
Ceiling inspection. Phone #: ###-#### ceiling ok
|
ELE07-00899
| Electrical Rough-In | 3/19/2007 | 3/19/2007 | 3/19/2007 1:33:40 PM | P | PART |
|
|
Bonding Larry; Phone #: ###-#### Internet Inspection Request from: Stacie Backus bonding and lights for pool and spa ok only equipotential grid not installed yet
|
ELE07-00880
| Temporary Service | 3/19/2007 | 3/19/2007 | 3/19/2007 12:48:44 PM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 3/19/2007 at 9:22:39 AM. Contact: ###-####. t/s o/h new ok
|
ELE07-00505
| Electrical Rough-In | 3/19/2007 | 3/19/2007 | 3/19/2007 12:23:24 PM | P | PART |
|
|
mitch; Phone #: ###-#### Internet Inspection Request from: Victoria Beall kit remodel ok
|
ELE07-00801
| Electrical Rough-In | 3/19/2007 | 3/19/2007 | 3/19/2007 11:57:15 AM | P | CANC |
|
|
Ryan; Phone #: ###-#### Internet Inspection Request from: Stacie Backus called this is a public works job, street light
|
ELE07-00750
| Electrical Rough-In | 3/16/2007 | 3/19/2007 | 3/19/2007 10:56:07 AM | A | CANC |
|
|
On site Journeyman - Randy ###-#### Phone #: ###-#### see added r/i p/s
|
ELE07-00750
| Rough-In Permanent Service | 3/19/2007 | 3/19/2007 | 3/19/2007 10:55:18 AM | A | PASS |
|
|
On site Journeyman - Randy ###-#### Phone #: ###-#### r/i p/s u/g new ok
|
ELE06-03876
| Final | 3/16/2007 | 3/19/2007 | 3/19/2007 10:26:20 AM | A | PASS |
|
|
made corrections. Phone #: ###-#### survey posted 210.8 gfci 1 kit recept
|
ELE07-00858
| Conference | 3/16/2007 | 3/19/2007 | 3/19/2007 9:55:39 AM | A | DONE |
|
|
We need an exterior soffit and block wall inspection. If there are any questions, please contact Travis at ###-####. Thank you. Phone #: ###-#### shall have journeyman at site apprentice working without journeyman
|
ELE07-00693
| Rough-In Permanent Service | 3/17/2007 | 3/19/2007 | 3/19/2007 9:20:40 AM | A | FAIL |
|
|
Joe Phone #: ###-#### corr. called BCC needs plans at site , all boxes , light fixtures shall be installed, all framing complete so elect. contr can wire walls, 250.66 install correct size bond to water pipes 210.52(A) outlets for wall space, 210.52(B) remove fam. rm from kit circuit, protect cables by attic accesses
|
ELE06-02392
| Electrical Rough-In | 3/16/2007 | 3/19/2007 | 3/19/2007 8:09:19 AM | A | PART |
|
|
randy - partial; Phone #: ###-#### Internet Inspection Request from: Victoria Beall 1st and 2nd floor warehouse walls
|