ELE08-00649
| Electrical Rough-In | 3/18/2008 | 3/19/2008 | 3/19/2008 3:11:44 PM | P | FAIL |
|
|
240 volt recep is ready for inspection Phone #: ###-#### Internet Inspection Request from: gary batten talked with owner he needs to remove the sink he installed below the panel
|
ELE08-00418
| Final | 3/19/2008 | 3/19/2008 | 3/19/2008 2:28:38 PM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Alan Lusk ok core shell card signed
|
ELE07-03440
| Final | 3/19/2008 | 3/19/2008 | 3/19/2008 2:28:12 PM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Alan Lusk ok core shell card signed
|
ELE08-00420
| Final | 3/19/2008 | 3/19/2008 | 3/19/2008 2:27:45 PM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Alan Lusk ok core shell card signed
|
ELE08-00419
| Final | 3/19/2008 | 3/19/2008 | 3/19/2008 2:27:12 PM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Alan Lusk ok core shell card signed
|
ELE08-00574
| Permanent Service | 3/19/2008 | 3/19/2008 | 3/19/2008 12:51:39 PM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Jarrod Clymer p/s u/g new ok
|
ELE08-00644
| Electrical Rough-In | 3/19/2008 | 3/19/2008 | 3/19/2008 11:53:21 AM | P | PASS |
|
|
Eddie also a final? Phone #: ###-#### ok
|
ELE08-00644
| Final | 3/19/2008 | 3/19/2008 | 3/19/2008 11:53:10 AM | P | PASS |
|
|
Eddie also a final? Phone #: ###-#### ok
|
ELE08-00646
| Electrical Rough-In | 3/18/2008 | 3/19/2008 | 3/19/2008 10:14:29 AM | A | PART |
|
|
Phone #: ###-#### Internet Inspection Request from: JENNY EMEL u/g ok
|
ELE08-00296
| Electrical Rough-In | 3/18/2008 | 3/19/2008 | 3/19/2008 9:44:18 AM | A | PART |
|
|
Scheduled by a contractor via Hello! on 3/18/2008 at 2:01:17 PM. Contact: ###-####. 2nd level of u/g ok
|
ELE08-00641
| Permanent Service | 3/18/2008 | 3/19/2008 | 3/19/2008 9:08:15 AM | A | FAIL |
|
|
Ready for service inspection so we can get IPCo connected. Then we will turn on power and determine what needs to be fixed. Phone #: ###-#### Internet Inspection Request from: Mick Williams corr called 312.5(C) exception ser not allowed in conduit, unless it exits the top, needs concrete encased electrode, 250.104(A)(1) bond water to service not sub panel, 110.3(A&B) use proper sized lugs or terminals for conductors250.142(B) 4 wire recepts and pigtails for range and dryer, 100.12(A) seal unused 2" top of sub panel
|
ELE08-00651
| Temporary Service | 3/18/2008 | 3/19/2008 | 3/19/2008 8:07:49 AM | A | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Alan Lusk t/s u/g new ok
|