ELE06-02952
| Final | 3/19/2008 | 3/19/2008 | 3/19/2008 4:21:04 PM | P | PASS |
|
|
ok to final
|
ELE06-02762
| Electrical Rough-In | 3/19/2008 | 3/19/2008 | 3/19/2008 3:38:29 PM | P | CANC |
|
|
Partial rough-in inspection. Either A.M. or P.M. is fine. Pleae call Jim at ###-#### 10 minutes before arrival. I will provide access. Phone #: ###-#### Internet Inspection Request from: James Cornwell see conference
|
ELE06-02762
| Conference | 3/19/2008 | 3/19/2008 | 3/19/2008 3:38:09 PM | P | DONE |
|
|
Partial rough-in inspection. Either A.M. or P.M. is fine. Pleae call Jim at ###-#### 10 minutes before arrival. I will provide access. Phone #: ###-#### Internet Inspection Request from: James Cornwell reviewed make-up requirements, 1/14" for mc, nm, and ent, 6" free conductor, outlet spacing, low voltage grounding for distribution box
|
ELE08-00259
| Final | 3/19/2008 | 3/19/2008 | 3/19/2008 3:08:11 PM | P | PASS |
|
|
Eric Phone #: ###-#### ok to final
|
ELE07-03738
| Final | 3/19/2008 | 3/19/2008 | 3/19/2008 2:25:32 PM | P | PASS |
|
|
House will be opened from 12:30 to 4:30 Phone #: ###-#### Internet Inspection Request from: Roy Kay owners moved into bedrooms, could not check receptacles, rest ok, ok to final
|
ELE08-00562
| Electrical Rough-In | 3/19/2008 | 3/19/2008 | 3/19/2008 1:29:39 PM | P | PASS |
|
|
jeff Phone #: ###-#### ok to cover inside house only, will call back for concrete encased electrode
|
ELE08-00653
| Temporary Service | 3/19/2008 | 3/19/2008 | 3/19/2008 12:41:54 PM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Shaun Kirkman t/s o/h n ok
|
ELE07-03958
| Final | 3/18/2008 | 3/19/2008 | 3/19/2008 11:27:56 AM | A | PASS |
|
|
rocky Phone #: ###-#### corrections made, ok to final
|
ELE07-02422
| Conference | 3/17/2008 | 3/19/2008 | 3/19/2008 10:18:51 AM | A | DONE |
|
|
Perry ###-#### talked about service, subpanels, ground rods, wire bending radius, oversize lb, receptacles, feed subpanel back to back, pull box
|
ELE08-00493
| Final | 3/17/2008 | 3/19/2008 | 3/19/2008 9:35:57 AM | A | PASS |
|
|
re-inspection. front unit will be unlocked. tenant will be home in rear unit. Phone #: ###-#### Internet Inspection Request from: Carla Ward called contractor, corrections made, ok to final
|
ELE08-00549
| Rough-In Permanent Service | 3/18/2008 | 3/19/2008 | 3/19/2008 9:12:34 AM | A | FAIL |
|
|
justin Phone #: ###-#### called, left correction notice, BCC address shall be posted, job id sticker shall be posted, approved set of plans shall be on job, wiring shall be terminated in boxes, NEC 362.30(A) ent shall be securely fastened within 3' of box, 362.46 bushings or adapter shall be installed at box,334.30 nm cable shall be secured within 12" of box, 314.17 conductors entering boxes shall be protected from abrasion, 110.26(F)(2) no other equipment shall be located in dedicated space about electrical equipment-lv under meter
|
ELE08-00548
| Rough-In Permanent Service | 3/18/2008 | 3/19/2008 | 3/19/2008 8:28:41 AM | A | FAIL |
|
|
justin Phone #: ###-#### called left correction notice, BCC address shall be posted, job id sticker shall be posted, approved set of plans shall be on job, wiring shall be terminated in boxes, NEC 362.30(A) ent shall be securely fastened within 3' of box, 362.46 bushings or adapter shall be installed at box, 334.30 nm cable shall be secured within 12" of box, 314.17 conductors entering boxes shall be protected from abrasion, 110.26(F)(2) no other equipment shall be located in dedicated space about electrical equipment-lv under meter
|