Inspections for the day of: Friday, March 19, 2010.
Number of inspections: 18
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE08-02640 ELE-Aging Inspection3/19/20103/19/20103/22/2010 9:59:44 AM CANC
ELE09-02367 ELE-Aging Inspection3/19/20103/19/20103/22/2010 9:59:30 AM CANC
ELE08-02676 ELE-Aging Inspection3/19/20103/19/20103/22/2010 9:59:21 AM CANC
ELE09-02386 Final3/19/20103/19/20103/19/2010 2:52:29 PMPNR
Need to get final electrical inspection on residence. Only item not finished is exterior light pole, this will not be complete till landscape is done. Call with any questions. Inspection requested from web by: Kurt Carlson Phone #: ###-#### called
ELE10-00448 Permanent Service3/19/20103/19/20103/19/2010 2:30:01 PMPFAIL
bill Phone #: ###-#### corr grd or bond water system, 250.52 or 104 T310.16 4/0 copper, or 250 alum for com. 200 amp p/s check clearence for service drop
ELE07-02082 Electrical Rough-In3/19/20103/19/20103/19/2010 2:11:17 PMPFAIL
Steve or Jack Phone #: ###-#### job still not ready and violations loose splices, countertop outlet spacing, makeup not complete , are some of the violations, job is a mess
ELE10-00489 Final3/19/20103/19/20103/19/2010 1:03:06 PMPPASS
Inspection requested from web by: TOM BICANDI Phone #: ###-#### ok
ELE09-02376 Final3/19/20103/19/20103/19/2010 12:27:09 PMPPASS
ELE09-02376 ELE-Aging Inspection3/19/20103/19/20103/19/2010 11:41:07 AM CANC
ELE09-02342 Permanent Service3/18/20103/19/20103/19/2010 11:38:56 AMACANC
john - please call 1/2 hr prior Phone #: ###-####
ELE09-02343 Permanent Service3/18/20103/19/20103/19/2010 11:38:46 AMAPASS
john - please call 1/2 hr prior Phone #: ###-#### ok
ELE10-00419 Final3/18/20103/19/20103/19/2010 10:29:14 AMAPASS
HZ Phone #: ###-#### ok
ELE10-00555 Temporary Service3/18/20103/19/20103/19/2010 10:28:53 AMAPASS
re-inspection temp pole Inspection requested from web by: Rowdy Monroe Phone #: ###-#### t/s u/g new ok
ELE10-00483 Rough-In Permanent Service3/18/20103/19/20103/19/2010 9:14:33 AMAPASS
Thank you! Inspection requested from web by: Tracy Robertson Phone #: ###-####
r/i p/s u/g new ok
ELE10-00219 Electrical Rough-In3/19/20103/19/20103/19/2010 8:17:59 AMAPASS
ELE10-00219 Final3/19/20103/19/20103/19/2010 8:17:50 AMAPASS
ELE10-00269 Final3/18/20103/19/20103/19/2010 8:17:27 AMAPASS
Tom is the contact his phone number is ###-####. Inspection requested from web by: Shawna Gates Phone #: ok card signed
ELE10-00555 Temporary Service3/18/20103/19/20103/18/2010 11:16:16 AMACANC
Inspection requested from web by: Rowdy Monroe Phone #: ###-#### Inspection cancelled from web by: Rowdy Monroe