ELE11-02700
| ELE-Aging Inspection | 3/19/2013 | 3/19/2013 | 3/19/2013 3:31:31 PM | | DONE |
|
|
have called contractor, waiting for call for final
|
ELE13-00124
| Final | 3/19/2013 | 3/19/2013 | 3/19/2013 2:44:21 PM | P | PASS |
|
|
Garage entrance code 1968E. Phone #: ###-#### >> Inspection requested via web by Alan Lusk ok final
|
ELE13-00534
| Permanent Service | 3/19/2013 | 3/19/2013 | 3/19/2013 2:01:28 PM | P | PASS |
|
|
I had to move the meter base. Needs to be restickered.The Phone #: ###-#### >> Inspection requested via web by Bob Glenn p/s u/g n ok
|
ELE13-00435
| Electrical Rough-In | 3/19/2013 | 3/19/2013 | 3/19/2013 12:55:47 PM | P | PASS |
|
|
Need a ceiling inspection. Contact Fabian for any questions. Phone #: ###-#### >> Inspection requested via web by Tina Payne ok cover ceiling
|
ELE13-00358
| Electrical Rough-In | 3/18/2013 | 3/19/2013 | 3/19/2013 10:46:39 AM | A | PASS |
|
|
Contact is Phil Bassack - NOTE: THIS INSPECTION IS TO REVIEW U.L. LISTINGS OF EQUIPMENT FURNISHED PER REQUEST FROM BOB REICHERT Phone #: ###-#### >> Inspection requested via web by Scott Campbell saw equipment listings for heads and contactor boxes
|
ELE13-00638
| Electrical Rough-In | 3/19/2013 | 3/19/2013 | 3/19/2013 10:45:16 AM | P | PASS |
|
|
Tony Phone #: ###-#### work done without permit until today, left correction notice 2-27-13 stating to get permit, could only see wiring in receptacles, general contractor pulled electrical permit, he said electrician did work, told contractor to provide circuit directory and provide work space around panel, ri ok, see final
|
ELE13-00638
| Final | 3/19/2013 | 3/19/2013 | 3/19/2013 10:44:59 AM | A | PASS |
|
|
Tony Phone #: ###-#### ok final
|
ELE13-00631
| Rough-In Permanent Service | 3/18/2013 | 3/19/2013 | 3/19/2013 9:54:35 AM | A | CANC |
|
|
Trench cover Phone #: ###-#### >> Inspection requested via web by David Seilheimer see ri
|
ELE13-00631
| Electrical Rough-In | 3/19/2013 | 3/19/2013 | 3/19/2013 9:36:19 AM | A | PASS |
|
|
Trench cover Phone #: ###-#### >> Inspection requested via web by David Seilheimer ok cover trench, check for schedule 80 riser
|
ELE13-00592
| Electrical Rough-In | 3/18/2013 | 3/19/2013 | 3/19/2013 9:32:34 AM | A | PASS |
|
|
pool and spa bonding--UG cover Phone #: ###-#### >> Inspection requested via web by Kevin Koomler pool and spa bond ok, u/g ok cover
|
ELE13-00611
| Temporary Service | 3/18/2013 | 3/19/2013 | 3/19/2013 9:11:15 AM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Rowdy Monroe t/s u/g n ok
|
ELE13-00333
| Final | 3/19/2013 | 3/19/2013 | 3/19/2013 8:49:39 AM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Rowdy Monroe ok final
|
ELE13-00610
| Rough-In Permanent Service | 3/18/2013 | 3/19/2013 | 3/19/2013 8:40:12 AM | A | FAIL |
|
|
Phone #: ###-#### >> Inspection requested via web by Rowdy Monroe called, left correction notice, NEC 314.17(C) nm cable shall be stapled within 8" of box, 300.4(A)(1) shall add nailplates if edge of bored hole is less than 1 1/4" from face of framing member, 210.52 shall add receptacle in wall over 2', BCC shall add box for bath light, shall not cover any wiring prior to inspection- foam in holes
|