ELE18-00727
| Conference | 3/19/2018 | 3/19/2018 | 3/19/2018 2:44:04 PM | P | FAIL |
|
|
110.9 Interrupting Rating. Equipment intended to interrupt current at fault levels shall have an interrupting rating at nominal circuit voltage at least equal to the current that is available at the line terminals of the equipment. Equipment intended to interrupt current at other than fault levels shall have an interrupting rating at nominal circuit voltage at least equal to the current that must be interrupted. NEC 110.10- Circuit Impedance, Short-Circuit Current Ratings, and Other Characteristics. The overcurrent protective devices, the total impedance, the equipment short-circuit current ratings, and other characteristics of the circuit to be protected shall be selected and coordinated to permit the circuit protective devices used to clear a fault to do so without extensive damage to the electrical equipment of the circuit. This fault shall beassumed to be either between two or more of the circuit conductors or between any circuit conductor and the equipment grounding conductor(s) permitted in 250.118. Listed equipment applied in accordance with their listing shall be considered to meet the requirements of this section. On 3-12-18 checked available short circuit current off service located on property to sub-gear at structure being built using Eaton FC2 available fault current calculator. Available fault current at main disconnecting means, 62,561 amps, 75' to building equipment, 2 parallel runs of 600 kcmil copper conductors. App states total available short circuit current at building equipment is 36,867 amps and 10k rated branch circuit overcurrent devices. Please submit back to engineer for correction. Must see documentation of correction of available short circuit values.
|
ELE18-00870
| Electrical Rough-In | 3/16/2018 | 3/19/2018 | 3/19/2018 12:48:23 PM | P | PASS |
|
|
pool and spa bonding Phone #: ###-#### Inspection requested via web by Kevin Koomler Hot tub bonding rough in ok cover
|
ELE18-00996
| Rough-In Permanent Service | 3/16/2018 | 3/19/2018 | 3/19/2018 11:30:26 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Alan Lusk Rough in ok cover p/s u/g n ok
|
ELE17-03999
| Final | 3/16/2018 | 3/19/2018 | 3/19/2018 10:02:30 AM | A | PASS |
|
|
Code 2010 Phone #: ###-#### Inspection requested via web by danny perrine Final ok
|
ELE17-04310
| Final | 3/18/2018 | 3/19/2018 | 3/19/2018 9:42:30 AM | A | PASS |
|
|
Garage code 1001E Phone #: ###-#### Inspection requested via web by Alan Lusk Final ok
|
ELE18-00839
| Rough-In Permanent Service | 3/19/2018 | 3/19/2018 | 3/19/2018 8:55:36 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Todd Hall Rough in ok cover p/s u/g n ok
|
ELE18-00840
| Rough-In Permanent Service | 3/19/2018 | 3/19/2018 | 3/19/2018 8:48:20 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Todd Hall Rough in ok cover p/s u/g n ok
|