Inspections for the day of: Monday, March 19, 2018.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorTom Saunders
TitleELE-INSPECTOR
Phone #208-794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE18-00985 Electrical Rough-In3/19/20183/19/20183/19/2018 3:12:52 PMPPASS
Rough in inspection Phone #: ###-#### Inspection requested via web by Louis Keller...approval for partial rough-in...ok to cover sink wall and cooktop wall only
ELE18-00408 Electrical Rough-In3/16/20183/19/20183/19/2018 2:43:14 PMPPASS
We need a wall cover inspection. Dustin is the site contact. Phone #: ###-#### Inspection requested via web by Stacie Tasker...wall cover ok dated and marked on plans
ELE17-04059 Final3/19/20183/19/20183/19/2018 2:02:50 PMPFAIL
Call for access- Jay Phone #: ###-####...
1. all outlets in garage shall have GFCI protection..furnace/water heater area
2. exterior outlets shall be weather resistant outlets...back weater proof
3. branch circuit serving microwave shall have a breaker lock out installed on it
ELE18-00527 Final3/19/20183/19/20183/19/2018 1:24:57 PMPPASS
Phone #: ###-#### Inspection requested via web by Jim Williams...ok to final
ELE18-00702 Final3/19/20183/19/20183/19/2018 12:34:05 PMPCANC
Final Inspection Phone #: ###-#### Inspection requested via web by Paula Gietzen...should of scheduled perm service inspection
ELE18-00702 Permanent Service3/19/20183/19/20183/19/2018 12:33:33 PMPFAIL
Final Inspection Phone #: ###-#### Inspection requested via web by Paula Gietzen..2nd ground vrod needs installed for perminent service
ELE18-00999 Final3/16/20183/19/20183/19/2018 12:02:01 PMAFAIL
Phone #: ###-#### Inspection requested via web by Ryan Wilson...no access
ELE18-00675 Electrical Rough-In3/18/20183/19/20183/19/2018 9:43:19 AMAPASS
r/I for 2nd bathroom, please call in advance for access. am or pm will work. 1st bathroom ready for final. Still haven''t seen HVAC contractor for exhaust venting?? Phone #: ###-#### Inspection requested via web by Rex Boyles...ok to cover bath 2
ELE18-00675 Final3/19/20183/19/20183/19/2018 9:42:54 AMAPART
r/I for 2nd bathroom, please call in advance for access. am or pm will work. 1st bathroom ready for final. Still haven''t seen HVAC contractor for exhaust venting?? Phone #: ###-#### Inspection requested via web by Rex Boyles...bath 1 checks out ok
ELE17-03469 Final3/19/20183/19/20183/19/2018 9:20:15 AMAPASS
for tile heat...GFCI protection ok
ELE17-04026 Final3/16/20183/19/20183/19/2018 9:18:38 AMAFAIL
2351 code Phone #: ###-#### Inspection requested via web by danny perrine...
1. all outlets in kitchen shall have GFCI protection..island outlet
2. intersystem bond bar shall be installed at service location
3. outlets in garage on back wall not working properly...check GFI...show hot ground/ reverse
4. W/P covers for outside outlets shall be in-use heavy duty covers
ELE17-02445 Electrical Rough-In3/16/20183/19/20183/19/2018 8:32:43 AMAPASS
Please Call Mike Phone #: ###-#### Inspection requested via web by Kevin Perez...wall cover ok as marked on plans