ELE18-00985
| Electrical Rough-In | 3/19/2018 | 3/19/2018 | 3/19/2018 3:12:52 PM | P | PASS |
|
|
Rough in inspection Phone #: ###-#### Inspection requested via web by Louis Keller...approval for partial rough-in...ok to cover sink wall and cooktop wall only
|
ELE18-00408
| Electrical Rough-In | 3/16/2018 | 3/19/2018 | 3/19/2018 2:43:14 PM | P | PASS |
|
|
We need a wall cover inspection. Dustin is the site contact. Phone #: ###-#### Inspection requested via web by Stacie Tasker...wall cover ok dated and marked on plans
|
ELE17-04059
| Final | 3/19/2018 | 3/19/2018 | 3/19/2018 2:02:50 PM | P | FAIL |
|
|
Call for access- Jay Phone #: ###-####... 1. all outlets in garage shall have GFCI protection..furnace/water heater area 2. exterior outlets shall be weather resistant outlets...back weater proof 3. branch circuit serving microwave shall have a breaker lock out installed on it
|
ELE18-00527
| Final | 3/19/2018 | 3/19/2018 | 3/19/2018 1:24:57 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Jim Williams...ok to final
|
ELE18-00702
| Final | 3/19/2018 | 3/19/2018 | 3/19/2018 12:34:05 PM | P | CANC |
|
|
Final Inspection Phone #: ###-#### Inspection requested via web by Paula Gietzen...should of scheduled perm service inspection
|
ELE18-00702
| Permanent Service | 3/19/2018 | 3/19/2018 | 3/19/2018 12:33:33 PM | P | FAIL |
|
|
Final Inspection Phone #: ###-#### Inspection requested via web by Paula Gietzen..2nd ground vrod needs installed for perminent service
|
ELE18-00999
| Final | 3/16/2018 | 3/19/2018 | 3/19/2018 12:02:01 PM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Ryan Wilson...no access
|
ELE18-00675
| Electrical Rough-In | 3/18/2018 | 3/19/2018 | 3/19/2018 9:43:19 AM | A | PASS |
|
|
r/I for 2nd bathroom, please call in advance for access. am or pm will work. 1st bathroom ready for final. Still haven''t seen HVAC contractor for exhaust venting?? Phone #: ###-#### Inspection requested via web by Rex Boyles...ok to cover bath 2
|
ELE18-00675
| Final | 3/19/2018 | 3/19/2018 | 3/19/2018 9:42:54 AM | A | PART |
|
|
r/I for 2nd bathroom, please call in advance for access. am or pm will work. 1st bathroom ready for final. Still haven''t seen HVAC contractor for exhaust venting?? Phone #: ###-#### Inspection requested via web by Rex Boyles...bath 1 checks out ok
|
ELE17-03469
| Final | 3/19/2018 | 3/19/2018 | 3/19/2018 9:20:15 AM | A | PASS |
|
|
for tile heat...GFCI protection ok
|
ELE17-04026
| Final | 3/16/2018 | 3/19/2018 | 3/19/2018 9:18:38 AM | A | FAIL |
|
|
2351 code Phone #: ###-#### Inspection requested via web by danny perrine... 1. all outlets in kitchen shall have GFCI protection..island outlet 2. intersystem bond bar shall be installed at service location 3. outlets in garage on back wall not working properly...check GFI...show hot ground/ reverse 4. W/P covers for outside outlets shall be in-use heavy duty covers
|
ELE17-02445
| Electrical Rough-In | 3/16/2018 | 3/19/2018 | 3/19/2018 8:32:43 AM | A | PASS |
|
|
Please Call Mike Phone #: ###-#### Inspection requested via web by Kevin Perez...wall cover ok as marked on plans
|