ELE05-00665
| Temporary Service | 3/1/2005 | 3/2/2005 | 3/2/2005 12:00:00 AM | A | PASS |
|
|
kathy ###-#### t/s u/g n ok 3/2/2005 7:30:06 AM
|
ELE05-00668
| Temporary Service | 3/1/2005 | 3/2/2005 | 3/2/2005 12:00:00 AM | A | FAIL |
|
|
Kim; Phone #: ###-#### Internet Inspection Request from: Jan Rice 406.4(D) recpt shall project from faceplate, 406.8(B)(2) recpt shall use in-use cover, 310.12(C) ungrounded conductors shall not be white, BCC job id sticker shall be posted. Re-nspection fee due. called contr , left corr notice. 3/2/2005 10:16:57 AM
|
ELE05-00300
| Final | 3/2/2005 | 3/2/2005 | 3/2/2005 12:00:00 AM | A | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Bob Glenn called contr about check garage gfci and a/c fuses. ok to final 3/2/2005 9:33:21 AM
|
ELE05-00299
| Final | 3/2/2005 | 3/2/2005 | 3/2/2005 12:00:00 AM | A | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Bob Glenn called contr about 2 recpts and panel labels. ok to final 3/2/2005 9:53:49 AM
|
ELE04-04114
| Final | 3/1/2005 | 3/2/2005 | 3/2/2005 12:00:00 AM | A | FAIL |
|
|
Scheduled by a contractor via Hello! on 3/1/2005 at 2:37:58 PM. Contact: ###-####. called contr,358.6 emt fittings shall be listed, 314.15(A) wet locations shall be listed for wet locations, 225.22 raceways shall be raintight in wet locations, left corr notice 3/2/2005 8:52:02 AM
|
ELE05-00447
| Final | 3/2/2005 | 3/2/2005 | 3/2/2005 12:00:00 AM | A | FAIL |
|
|
358.6 emt fittings shall be listed, 314.15(A) wet locations shall be listed for use in wet locations, 225.22 raceways shall be raintight in wet locations, called contr, left corr notice
|
ELE03-01485
| Final | 3/1/2005 | 3/2/2005 | 3/2/2005 12:00:00 AM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 3/1/2005 at 10:01:27 AM. Contact: ###-####. hot tub was installed, but has been removed and all wiring disconnected. ok to final 3/2/2005 4:25:00 PM
|
ELE05-00523
| Electrical Rough-In | 3/1/2005 | 3/2/2005 | 3/2/2005 12:00:00 AM | P | FAIL |
|
|
Robert; Phone #: ###-#### Internet Inspection Request from: Jan Rice 300.4(D) nm cable shall be 1 1/4" from edge, 314.17(C) nm shall be fastened within 8" of box, BCC all r/i shall be done, shall supply boxes for outside recpts and lighting, left corr. notice, told son 3/2/2005 1:35:16 PM
|
ELE05-00669
| Rough-In Permanent Service | 3/2/2005 | 3/2/2005 | 3/2/2005 12:00:00 AM | P | PASS |
|
|
leon ###-#### called contr and said they have to have app. plans on job. ric ok p/s u/g n ok 3/2/2005 2:05:33 PM
|
ELE05-00045
| Final | 3/2/2005 | 3/2/2005 | 3/2/2005 12:00:00 AM | P | PASS |
|
|
rundle electric; Phone #: ###-#### Internet Inspection Request from: Barbara Moore people have all furniture moved into new addition. Able to check 90% of outlets. rest ok, ok to final . Called contractor to verify that he was done and not doing rest of remodel work in exst bath. 3/2/2005 3:45:59 PM
|
ELE04-02821
| Final | 3/2/2005 | 3/2/2005 | 3/2/2005 12:00:00 AM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 3/2/2005 at 8:33:20 AM. Contact: ###-####. ok to final. contr there and will put on covers in 2 plcs. finishing out door lite. 3/2/2005 1:00:45 PM
|