ELE06-00738
| Final | 3/2/2006 | 3/2/2006 | 3/2/2006 4:38:00 PM | P | NR |
|
|
NEED FINAL INSPECTION ON NEW CIRCUIT FOR A/C. THANK YOU.; Phone #: ###-#### Internet Inspection Request from: BRIAN KEITH told contr to call when done
|
ELE06-00415
| Final | 3/2/2006 | 3/2/2006 | 3/2/2006 4:37:19 PM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Dana Moyer ok to final
|
ELE05-03314
| Final | 3/1/2006 | 3/2/2006 | 3/2/2006 2:57:34 PM | P | PASS |
|
|
Tim -- call 1st before insp; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong ok to final
|
ELE06-00735
| Electrical Rough-In | 3/2/2006 | 3/2/2006 | 3/2/2006 2:51:15 PM | P | FAIL |
|
|
###-#### - Note: RI and grounding ring met elect, left corr notice,300.4(A)&(D) edges of holes and edge of mc cable shall be 1 1/4" from edge of framing member, 312.5 all conductors entering enclosures shall have abrasion protection, 210.63 recpt shall be within 25 ft of a/c equipment, 330.30(B) mc cable shall be fastened within 12 " of box,314.23(B)(1) nails and screws used to fasten box shall use brackets on the outside of box or pass thru the interior within 1/4" of the back or ends of the enclosure, 800.133(A)(1) communications cables shall not be run in raceway with electric, light, power circuits,BCC all make-up shall be done. ok to pour gec. call before backfill Wrote correction notice to bld05-01394-BCC low voltage wiring shall be installed by licensed lv contractor
|
ELE05-00855
| Electrical Rough-In | 3/1/2006 | 3/2/2006 | 3/2/2006 9:45:54 AM | A | CANC |
|
|
CONTACT: LYLE DEAN - TEMPORARY OCCUPANCY INSPECTION; Phone #: ###-#### Internet Inspection Request from: Deb McCoy see final
|
ELE06-00165
| Electrical Rough-In | 3/1/2006 | 3/2/2006 | 3/2/2006 9:15:52 AM | A | PART |
|
|
Underground; Phone #: ###-#### Internet Inspection Request from: Kerri Hamilton u/g from driveway to sign ok to cover
|
ELE06-00222
| Final | 3/1/2006 | 3/2/2006 | 3/2/2006 8:50:32 AM | A | PASS |
|
|
jack; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa ok to final
|
ELE06-00727
| Electrical Rough-In | 3/1/2006 | 3/2/2006 | 3/2/2006 8:30:43 AM | P | CANC |
|
|
My cell number is ###-####, Thank you Randy; Phone #: ###-#### Internet Inspection Request from: Randy Fletcher Inspection cancelled from web by: Randy Fletcher
|
ELE05-04651
| Final | 3/1/2006 | 3/2/2006 | 3/2/2006 8:14:24 AM | A | PART |
|
|
Jeremy; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong talked to elect, ok to cover ceiling, need to see insta-hot and front areas when done, also check to see how projectors and misc equipment gets installed. rest ok
|
ELE05-00855
| Final | 3/2/2006 | 3/2/2006 | 3/2/2006 12:00:00 AM | A | PART |
|
|
CONTACT: LYLE DEAN - TEMPORARY OCCUPANCY INSPECTION; Phone #: ###-#### Internet Inspection Request from: Deb McCoy corrections made for first 3 floors of parking garage. Went to sign t/o card, but no card available.
|