Inspections for the day of: Friday, March 2, 2007.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE06-04430 ELE-Aging Inspection3/2/20073/2/20073/2/2007 4:23:32 PM DONE
see final
ELE06-04430 Final3/2/20073/2/20073/2/2007 4:21:45 PMPPASS
saw heat trace while doing inspection for main bldg, ok to final
ELE07-00657 Rough-In Permanent Service2/27/20073/2/20073/2/2007 3:52:21 PMPPASS
Contact: Bob Phone #: ###-#### ric ok, p/s u/g n ok, called contr to upgrade permit to 24 rooms
ELE07-00691 Rough-In Permanent Service3/2/20073/2/20073/2/2007 2:47:32 PMPPASS
bob; Phone #: ###-#### Internet Inspection Request from: Victoria Beall ric both sides ok, p/s u/g n ok 2207 only
ELE07-00694 Electrical Rough-In3/2/20073/2/20073/2/2007 1:55:29 PMPPASS
Brian will be there until 2:00 if possible to meet him please. Phone #: ###-#### x0000 see final, told elect to provide bkr lockout ri ok
ELE07-00694 Final3/2/20073/2/20073/2/2007 1:53:59 PMPPASS
Brian will be there until 2:00 if possible to meet him please. Phone #: ###-#### x0000 met elect told via survey to provide lock-out for water heater, ok to final
ELE07-00541 Electrical Rough-In3/2/20073/2/20073/2/2007 1:33:56 PMPPASS
bill; Phone #: ###-#### Internet Inspection Request from: Victoria Beall corr made, ok to cover except at panel, need to see feeder coming in from house, which will be done by contr ltr
ELE07-00516 Final3/2/20073/2/20073/2/2007 1:13:25 PMPPART
walls and ceiling final. If you have any questions please call. Phone #: ###-#### see ri for ceiling only. No power for recpts, told to fix and call back in downstairs only, no elect upstairs.
ELE07-00516 Electrical Rough-In3/2/20073/2/20073/2/2007 1:11:35 PMPPASS
walls and ceiling final. If you have any questions please call. Phone #: ###-#### ok to cover ceiling downstairs only, did not leave sticker, called contr to explain- no power on recpts
ELE07-00182 Conference3/2/20073/2/20073/2/2007 12:42:53 PMPDONE
Scheduled by a contractor via Hello! on 3/2/2007 at 7:33:42 AM. Contact: ###-####. looked at lighting requirement and cord connections, elect room , main area for any changes that may be required prior to final
ELE07-00026 Final3/2/20073/2/20073/2/2007 12:17:23 PMPPASS
Phone #: ###-#### ok to final, signed occ card
ELE07-00678 Temporary Service3/1/20073/2/20073/2/2007 10:05:00 AMAPASS
reinspection on temp power pole Phone #: ###-#### corr made, t/s o/h n ok
ELE06-03928 Final3/2/20073/2/20073/2/2007 9:28:12 AMAPASS
Please call for access. Let me know if there are any questions or problems. Thank You Phone #: ###-#### ok to final
ELE07-00541 Electrical Rough-In2/28/20073/2/20073/2/2007 8:48:49 AMAFAIL
Bill; Phone #: ###-#### Internet Inspection Request from: Stacie Backus met owner, left corr notice, nec 250.86 all metal boxes shall be grounded with approved green ground screws,334.30 nm cable shall be secured within 12" of box, 110.3(B) romex 2 screw connector shall not be used on gec, 250.148(B) grounds shall be such that continuity is not broken by device removal (tie all together in box)
ELE07-00684 Electrical Rough-In3/1/20073/2/20073/2/2007 7:51:22 AMAPASS
We extended an existing 3 phase 480 volt circuit from the load side of the existing fused disconnect switch to a new stop/start control and to the new truss roller that it controls. This is beside the east truss table and is associated with the last job you inspected there under Permit #ELE07-00245. Able or Virgil can give you the tour.Thanks!!! Tech Jason ###-####. PO#7020195bmc. Phone #: ###-#### ri ok, see final
ELE07-00684 Final3/2/20073/2/20073/2/2007 7:50:35 AMPPASS
We extended an existing 3 phase 480 volt circuit from the load side of the existing fused disconnect switch to a new stop/start control and to the new truss roller that it controls. This is beside the east truss table and is associated with the last job you inspected there under Permit #ELE07-00245. Able or Virgil can give you the tour.Thanks!!! Tech Jason ###-####. PO#7020195bmc. Phone #: ###-#### ok to final