Inspections for the day of: Tuesday, March 2, 2010.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE10-00195 Final3/2/20103/2/20103/2/2010 4:14:42 PMPPASS
corey Phone #: ###-#### found sticker, ok to final, signed occupancy card, no esc this project
ELE09-02446 Final3/2/20103/2/20103/2/2010 3:37:40 PMPPASS
leo Phone #: ###-#### ok to final, no esc this project
ELE10-00400 Final3/2/20103/2/20103/2/2010 3:00:14 PMPCANC
PLEASE CALL IF THERE IS ARE PROBLEMS, MIKE ###-####. Inspection requested from web by: Mike TenHulzen Phone #: ###-#### see t/s
ELE10-00400 Temporary Service3/2/20103/2/20103/2/2010 2:59:59 PMPPASS
PLEASE CALL IF THERE IS ARE PROBLEMS, MIKE ###-####. Inspection requested from web by: Mike TenHulzen Phone #: ###-#### corrections made, t/s o/h n ok, no esc this project
ELE10-00412 Permanent Service3/2/20103/2/20103/2/2010 1:58:46 PMPPASS
Please inspect the new Service so that we can have the Service Drop relocated to the new Service. Please contact our Wireman, Seth at ###-#### as he is on-site. Thank you. Inspection requested from web by: Clint Tate Phone #: ###-#### p/s o/h rec ok, no esc this project, check water pipe ground in basement by computer set-up next trip, 2 ground rods installed for service change
ELE10-00386 Final3/2/20103/2/20103/2/2010 1:20:57 PMPPASS
Inspection requested from web by: Kevin Perez Phone #: ###-#### ok to final, no esc this project
ELE10-00386 Permanent Service3/2/20103/2/20103/2/2010 12:44:05 PMPPASS
Inspection requested from web by: Kevin Perez Phone #: ###-#### p/s o/h rec ok, no esc this project
GCE10-00009 GCE-Final3/2/20103/2/20103/2/2010 12:24:29 PMPPASS
don Phone #: ###-#### ok to final
ELE10-00185 Final3/1/20103/2/20103/2/2010 10:38:36 AMAPASS
Mike Phone #: ###-#### corrections made, ok to final, signed card, no esc
ELE10-00389 Temporary Service3/1/20103/2/20103/2/2010 10:36:49 AMAPASS
alan Phone #: ###-#### t/s o/h n ok, no esc this project
GCE10-00009 GCE-Final3/1/20103/2/20103/2/2010 10:01:16 AMAFAIL
Scope of Inspection: Final Inspection (indicated hot water tank was behind access door on side of home)AM If Possible could not locate address, not posted, no phone number listed- will need to recall for inspection, add contact phone number
ELE10-00405 Electrical Rough-In3/1/20103/2/20103/2/2010 9:32:42 AMAFAIL
Key under mat Inspection requested from web by: Dan Rohl Phone #: ###-#### called, left correction notice, NEC 300.4A&D edge of bored holes and nm cable and raceways shall be 1 1/4" from edge of framing members, 334.30 nm cable shall be stapled within 8" of box and not be stapled on edge, 110.26(F)(1) there shall be no piping in dedicated space over panel, BCC shall install fixtures and boxes for ri- down stairs and outside recpt, NOTE corrections shall be made within 5 working days or further action will be taken
ELE10-00246 Electrical Rough-In3/1/20103/2/20103/2/2010 8:32:59 AMAPASS
Inspection requested from web by: TOM BICANDI Phone #: ###-#### corrections made, ric ok
ELE10-00098 Final3/1/20103/2/20103/2/2010 8:04:12 AMANH
Lockbox code 1290, any questions, please give Clay a call. Thank You. Inspection requested from web by: Clay Morgan Phone #: ###-#### called, left message, code not working, no lock box, fee due