PLM15-03559
| Final | 3/2/2016 | 3/2/2016 | 3/2/2016 4:42:10 PM | P | FAIL |
|
|
if questions call Gary @ ###-####. Phone #: ###-#### Inspection requested via web by Stacia Haumann >Caulk DF and s. steel sinks >anchor dw's >water closets need open front seats >hookup remaing equipment >cap top of RP manifold
|
PLM16-00516
| Final | 3/1/2016 | 3/2/2016 | 3/2/2016 4:08:58 PM | P | PASS |
|
|
venting adjustment per last inspection Phone #: ###-#### Inspection requested via web by ron pierce
|
PLM16-00628
| Plumbing Rough-in | 3/2/2016 | 3/2/2016 | 3/2/2016 3:51:05 PM | P | FAIL |
|
|
Please call before you go so we can be there. Thanks Cinnamon Phone #: ###-#### Inspection requested via web by Cinnamon Dilworth >mst tub need p-trap >mst sh needs to tie into lav vent >3" c/o at base of stack >glue cap on abandoned vent >redo cross so trap arms are 1.5" entire length >redo vent connections with santees in the vertical >redo upper bath overhead >nail plates >dwv test fail >water ok
|
PLM16-00720
| Water Heater Final | 3/2/2016 | 3/2/2016 | 3/2/2016 2:40:28 PM | P | FAIL |
|
|
Please call homeowner Amy ###-#### when on the way. Thank you, Phone #: ###-#### Inspection requested via web by Jennifer Alcala >>need 1" clearance on b-vent @ roof penetration >need insulation shield around vent in attic >vent riser off wh needs to insert into swivel 90 ftg rather than over ftg as currently installed.
|
PLM16-00692
| Sprinkler (Final) | 3/2/2016 | 3/2/2016 | 3/2/2016 2:02:44 PM | P | PASS |
|
|
sprinkler dcva ok
|
PLM15-03634
| Final | 3/1/2016 | 3/2/2016 | 3/2/2016 2:01:08 PM | P | PASS |
|
|
waiting for sprinkler permit
|
PLM16-00597
| Final | 3/2/2016 | 3/2/2016 | 3/2/2016 1:45:16 PM | P | PASS |
|
|
Kitchen trim completed. Contractor on site Phone #: ###-#### Inspection requested via web by Scott Sparrell
|
PLM16-00452
| Final | 2/29/2016 | 3/2/2016 | 3/2/2016 1:18:05 PM | P | PASS |
|
|
Please call Ted at ###-#### before arriving, thank you. Phone #: ###-#### Inspection requested via web by TERESA HUTTO >wh ok and new vent connectors
|
PLM15-03483
| Final | 3/2/2016 | 3/2/2016 | 3/2/2016 11:40:49 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Randy Powell >Need tempering valve @ public lavatory >need a 1" airgap on t&p >install a S/O valve before DCVA >install S/O valve in occupied side of building. >support mop sink faucet
|
PLM16-00705
| DOC - Permit Finaled | 3/2/2016 | 3/2/2016 | 3/2/2016 11:04:23 AM | P | PASS |
|
|
|
PLM16-00705
| Water and/or Sewer | 3/1/2016 | 3/2/2016 | 3/2/2016 11:03:49 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Vicki Tallent
|
PLM16-00661
| Water and/or Sewer | 3/2/2016 | 3/2/2016 | 3/2/2016 10:54:57 AM | A | CANC |
|
|
|
PLM16-00661
| Sprinkler (Final) | 3/2/2016 | 3/2/2016 | 3/2/2016 10:54:56 AM | P | PASS |
|
|
|
PLM16-00685
| Water and/or Sewer | 2/29/2016 | 3/2/2016 | 3/2/2016 10:31:08 AM | A | NR |
|
|
Phone #: ###-#### Inspection requested via web by Travis Gingerich >not ready
|
PLM16-00686
| Water and/or Sewer | 2/29/2016 | 3/2/2016 | 3/2/2016 10:30:24 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Travis Gingerich >need to expose tie in tee and riser to backflow for inspection.
|
PLM16-00721
| DOC - Permit Finaled | 3/2/2016 | 3/2/2016 | 3/2/2016 10:05:47 AM | P | PASS |
|
|
|
PLM16-00719
| DOC - Permit Finaled | 3/2/2016 | 3/2/2016 | 3/2/2016 10:05:12 AM | P | PASS |
|
|
|
PLM16-00719
| Water and/or Sewer | 3/2/2016 | 3/2/2016 | 3/2/2016 10:04:21 AM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Brett Simmons
|
PLM16-00721
| Water and/or Sewer | 3/2/2016 | 3/2/2016 | 3/2/2016 10:03:11 AM | P | PASS |
|
|
Installation of outside water and sewer lines Phone #: ###-#### Inspection requested via web by Brett Simmons
|
PLM16-00052
| Final | 3/2/2016 | 3/2/2016 | 3/2/2016 9:53:48 AM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Branden Steers
|
PLM16-00706
| Water Heater Final | 3/1/2016 | 3/2/2016 | 3/2/2016 9:41:40 AM | A | PASS |
|
|
Please call ahead Cynthia Mosley ###-#### Phone #: ###-#### Inspection requested via web by Chris Field
|
PLM16-00366
| Water and/or Sewer | 3/1/2016 | 3/2/2016 | 3/2/2016 9:32:04 AM | A | NR |
|
|
MIKE IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER >not ready, moved inspection to tomorrow am per excavator.
|
PLM15-03495
| Final | 2/29/2016 | 3/2/2016 | 3/2/2016 9:10:20 AM | A | PASS |
|
|
This permit had the final inspection, the home owner was going to add some more water piping but changed his mind - please final out permit. Inspection requested via web by Marion Moody. >no further work done on this permit.
|
PLM16-00687
| Groundwork | 2/29/2016 | 3/2/2016 | 3/2/2016 9:09:29 AM | A | PASS |
|
|
Please call when on your way or estimated time of arrival Phone #: ###-#### Inspection requested via web by Marion Moody >gw ok
|
PLM16-00342
| Final | 3/1/2016 | 3/2/2016 | 3/2/2016 8:33:28 AM | A | PASS |
|
|
Plumber and main contact is Peterson please call him should you have questions at ###-####. Thank you! Phone #: ###-#### Inspection requested via web by Maira Guzman
|
PLM15-03588
| PLM-Aging Inspection | 3/2/2016 | 3/2/2016 | 3/2/2016 8:20:41 AM | | PART |
|
|
|
PLM16-00628
| Plumbing Rough-in | 3/1/2016 | 3/2/2016 | 3/2/2016 12:42:33 AM | A | CANC |
|
|
Please call when you are headed that way and I will meet you there.
Thx
Cinnamon
###-#### Phone #: ###-#### >> Inspection requested via web by Cinnamon Dilworth Inspection cancelled from web by: Cinnamon Dilworth
|