ELE17-02649
| Electrical Rough-In | 3/2/2018 | 3/2/2018 | 3/2/2018 3:20:03 PM | P | PART |
|
|
Contact is Andy Chambers - ceiling inspection Phone #: ###-#### Inspection requested via web by Scott Campbell Grid for rooms noted on print, storage 148 and office 177. Also tested nurses station and bathroom 185, and patient rooms 3 thru 6 and 8 thru 11. All have receptacles with in 6' of a sink which fall under 210.8(B)(5) exception 2 to 5. Contractor to verify catagory 2 patient bed general care space with architect. Noted on contractor print as well.
|
ELE17-03991
| Final | 3/1/2018 | 3/2/2018 | 3/2/2018 2:09:41 PM | P | PASS |
|
|
garage code 1234 Phone #: ###-#### Inspection requested via web by Jay Hutchison Final ok
|
ELE18-00237
| Final | 3/1/2018 | 3/2/2018 | 3/2/2018 2:09:12 PM | P | PASS |
|
|
garage code 1234 Phone #: ###-#### Inspection requested via web by Jay Hutchison Final ok
|
ELE18-00792
| Final | 3/1/2018 | 3/2/2018 | 3/2/2018 1:21:25 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Ryan Wilson Final ok
|
ELE18-00792
| Electrical Rough-In | 3/2/2018 | 3/2/2018 | 3/2/2018 1:21:06 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Ryan Wilson Mini split rough in ok cover
|
ELE18-00313
| Electrical Rough-In | 3/2/2018 | 3/2/2018 | 3/2/2018 1:11:42 PM | P | PART |
|
|
Pls contact Brad (Foreman) @ ###-#### or Preston (Electrician) @ ###-#### one hr prior or if you have any questions. Thank you. Inspection requested via web by Rob Maes Solar panels on back order, stated same brand normally used. Discussed signage for 2 seperate solar disconnecting means, 1 near service and 1 at exterior of other garage. Micro inverters and rack system listing confirmed.
|
ELE18-00765
| Temporary Service | 3/2/2018 | 3/2/2018 | 3/2/2018 12:36:45 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Alan Lusk t/s u/g n ok
|
ELE17-04207
| Final | 3/1/2018 | 3/2/2018 | 3/2/2018 11:31:42 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by cris flores Final ok
|
ELE17-03546
| Final | 3/1/2018 | 3/2/2018 | 3/2/2018 11:31:02 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by cris flores Final ok
|
ELE18-00231
| Electrical Rough-In | 3/1/2018 | 3/2/2018 | 3/2/2018 11:06:45 AM | A | PASS |
|
|
FLOOR HEAT Inspection only, access 4878 Phone #: ###-#### Inspection requested via web by David Nelson Master bath floor heat rough in ok cover
|
ELE18-00235
| Final | 3/2/2018 | 3/2/2018 | 3/2/2018 10:55:35 AM | P | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Patrick Paz Inspection cancelled from web by: Patrick Paz
|
ELE18-00603
| Electrical Rough-In | 3/1/2018 | 3/2/2018 | 3/2/2018 10:47:21 AM | A | PASS |
|
|
Contact is Jim Noll - wall rough-in inspection Phone #: ###-#### Inspection requested via web by Scott Campbell Walls and seating area so grid can be painted. Few open boxes above this grid tha will be checked next trip. Rough in noted ok cover
|
ELE18-00413
| Electrical Rough-In | 3/1/2018 | 3/2/2018 | 3/2/2018 10:45:48 AM | A | PART |
|
|
Phone #: ###-#### Inspection requested via web by Kerri Hamilton Boarders only due to existing floor boxes said to be abandoned with several open knockouts in them. They are spread through out entire ceiling. Boarders only rough in ok cover.
|
ELE17-04339
| Final | 3/2/2018 | 3/2/2018 | 3/2/2018 9:27:44 AM | P | PASS |
|
|
code 4224 . Ready now. Phone #: ###-#### Inspection requested via web by Bob Glenn Final ok
|
ELE18-00765
| Temporary Service | 3/1/2018 | 3/2/2018 | 3/2/2018 8:59:06 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Alan Lusk 110.27- Panel cover shall be in place to protect against accidental contact.
|
ELE18-00784
| Rough-In Permanent Service | 3/1/2018 | 3/2/2018 | 3/2/2018 8:47:28 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Alan Lusk Rough in ok cover p/s u/g n ok
|