MEC20-00571
| Rough-in | 3/1/2020 | 3/2/2020 | 3/2/2020 3:50:46 PM | P | FAIL |
|
|
Units 230 thru 239 . ###-#### Yuriy Phone #: ###-#### Inspection requested via web by yuriy kryachun - need City approved plans onsite
|
MEC20-00800
| Final | 2/26/2020 | 3/2/2020 | 3/2/2020 3:27:38 PM | P | PASS |
|
|
Please call Gary Neighbors prior to inspection. ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette - furnace ac coil co ok
|
MEC20-00861
| Rough-in | 3/2/2020 | 3/2/2020 | 3/2/2020 3:02:53 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Jose Lagunas - b vent upstairs needs 1" clearances - combustion air openings are not big enough, size openings per btu ratings of equipment being installed in mech room
|
MEC20-00861
| Pressure Test | 3/2/2020 | 3/2/2020 | 3/2/2020 3:01:12 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Jose Lagunas - 5lb flue pressure test ok - 20lb gas pressure test ok - tagged meter location
|
MEC19-05826
| Final | 3/2/2020 | 3/2/2020 | 3/2/2020 2:27:29 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak - range hood needs finished - condensate into washer box needs extended down into drain
|
MEC20-00865
| Final | 3/2/2020 | 3/2/2020 | 3/2/2020 2:00:01 PM | P | NR |
|
|
Please call tech Paul prior to arrival to ensure ready. ###-#### Phone #: ###-#### Inspection requested via web by Andrea Grigsby
|
MEC20-00613
| Final | 3/2/2020 | 3/2/2020 | 3/2/2020 1:33:36 PM | P | PASS |
|
|
Inspection requested via web by Sarah Small - final ok
|
MEC20-00532
| Final | 2/25/2020 | 3/2/2020 | 3/2/2020 1:19:30 PM | P | PASS |
|
|
PLEASE CALL HOMEOWNER BRIAN WHEN 30 MINS IN ROUTE Phone #: ###-#### Inspection requested via web by Rick Montgomery - final ok
|
MEC20-00264
| Final | 2/26/2020 | 3/2/2020 | 3/2/2020 11:25:06 AM | A | NR |
|
|
Phone #: ###-#### Inspection requested via web by Randy Hart - not ready range hood and water heater is not set - line set penetration will need sealed once siding is installed
|
MEC20-00722
| Final | 2/28/2020 | 3/2/2020 | 3/2/2020 10:57:28 AM | A | PASS |
|
|
The electrical was done by Sublime Electric. I called them to inform them that they needed to pull a permit. They told me that they''d have it pulled on Friday 02/28/20. Please check and pass our permit. Phone #: ###-#### Inspection requested via web by Arielle Hendricks - final ok
|
MEC19-05776
| Final | 2/28/2020 | 3/2/2020 | 3/2/2020 10:31:29 AM | A | PASS |
|
|
Garage Code 2464 - Builder ###-#### - HVAC ###-#### Phone #: ###-#### Inspection requested via web by Arielle Hendricks - final ok
|
MEC20-00449
| Rough-in | 2/29/2020 | 3/2/2020 | 3/2/2020 10:18:27 AM | A | PASS |
|
|
Cover inspection Phone #: ###-#### Inspection requested via web by RaChelle Frisbee - R/I ceiling cover ok
|
MEC20-00335
| Rough-in | 2/27/2020 | 3/2/2020 | 3/2/2020 9:24:02 AM | A | PART |
|
|
duct seal inspection Phone #: ###-#### Inspection requested via web by Brandon Sorensen - duct seal ok for insulation
|
MEC19-04828
| Final | 2/28/2020 | 3/2/2020 | 3/2/2020 8:41:57 AM | A | FAIL |
|
|
Back door is unlocked Phone #: ###-#### Inspection requested via web by Michael Stimpson - A/C needs locking caps installed on service ports - line set penetration needs sealed - gas line at meter needs two supports - range vent needs to be smooth walled pipe
|
MEC19-02071
| Mec-Aging Inspection | 3/2/2020 | 3/2/2020 | 3/2/2020 8:19:22 AM | | PASS |
|
|
Doc Permit Expired ok
|
MEC19-02071
| DOC - Permit Expired | 3/2/2020 | 3/2/2020 | 3/2/2020 8:19:05 AM | A | PASS |
|
|
Doc Permit Expired ok permit not active
|
MEC19-02074
| Mec-Aging Inspection | 3/2/2020 | 3/2/2020 | 3/2/2020 8:18:25 AM | | PASS |
|
|
Doc Permit Expired ok
|
MEC19-02074
| DOC - Permit Expired | 3/2/2020 | 3/2/2020 | 3/2/2020 8:01:45 AM | A | PASS |
|
|
Doc Permit Expired ok permit not active
|