Inspections for the day of: Thursday, March 20, 2008.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBill VanDegrift
TitlePLM-INSPECTOR
Phone #794-9372
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM08-00581 Plumbing Rough-in3/20/20083/20/20083/20/2008 4:51:42 PMPNR
Phone #: ###-#### Internet Inspection Request from: Gary Ziegler
PLM08-00575 Plumbing Rough-in3/20/20083/20/20083/20/2008 3:40:05 PMPCANC
scott Phone #: ###-#### nail plates needed on the water softener p-trap vent on the 2nd floor.. master tub waste is backgraded at its connection with the lav drain in the 1st floor ceiling.
PLM08-00580 Water and/or Sewer3/20/20083/20/20083/20/2008 3:00:32 PMPPASS
brett Phone #: ###-####
PLM08-00142 Plumbing Rough-in3/20/20083/20/20083/20/2008 2:44:18 PMPFAIL
troy Phone #: ###-#### vent washer p-trap. a water heater pan will be required, looks like a pump will be required to accept the discharge.
PLM07-04133 Plumbing Rough-in3/20/20083/20/20083/20/2008 2:25:04 PMPPART
shell and core only........ provide resubmittals for the porch/walkway drains on the second floor that have been added. 3" is the min. horizontal roof drainage piping.. test on shell risers and water main through building is ok.
MEC07-00187 Final3/19/20083/20/20083/20/2008 10:59:45 AMAPASS
petsche Phone #: ###-####
MEC07-03994 Final3/18/20083/20/20083/20/2008 10:45:43 AMAPASS
DIXIE, LATE PM PLEASE, LLOYD & CORKY WILL BE THERE Internet Inspection Request from: Donna Bledsoe
MEC08-00822 Rough-in3/19/20083/20/20083/20/2008 10:15:55 AMAPART
justin Note: Just Part RI Phone #: ###-#### partial ri ok kitchen exhaust, minor ducting in kitchen ceiling
MEC08-00831 Rough-in3/20/20083/20/20083/20/2008 9:53:46 AMPPASS
Contact John Kramis Phone #: ###-#### Internet Inspection Request from: Frank Marturello ri ok
MEC08-00823 Final3/19/20083/20/20083/20/2008 9:53:22 AMAPASS
Anthony; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt
MEC08-00823 Pressure Test3/19/20083/20/20083/20/2008 9:52:22 AMPPASS
Anthony; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt 20# test ok
MEC08-00825 Final3/19/20083/20/20083/20/2008 9:28:48 AMANR
Anthony; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt
PLM07-04020 PLM-Aging Inspection3/20/20083/20/20083/20/2008 8:49:12 AM PASS
I think their all done
PLM08-00048 PLM-Aging Inspection3/20/20083/20/20083/20/2008 8:47:46 AM PASS
PLM05-03755 PLM-Aging Inspection3/20/20083/20/20083/20/2008 8:46:58 AM PASS