ELE13-00373
| ELE-Aging Inspection | 3/20/2015 | 3/20/2015 | 3/20/2015 3:11:46 PM | | DONE |
|
|
Still under construction
|
ELE12-02580
| ELE-Aging Inspection | 3/20/2015 | 3/20/2015 | 3/20/2015 3:10:45 PM | | DONE |
|
|
Waiting on owner
|
ELE13-00368
| ELE-Aging Inspection | 3/20/2015 | 3/20/2015 | 3/20/2015 3:08:34 PM | | DONE |
|
|
Still under construction
|
ELE15-00683
| Electrical Rough-In | 3/20/2015 | 3/20/2015 | 3/20/2015 3:07:55 PM | P | PASS |
|
|
Ceiling as late as possible Phone #: ###-#### Inspection requested via web by Bryan McLaughlin Grid rough in ok cover
|
ELE15-00739
| Rough-In Permanent Service | 3/20/2015 | 3/20/2015 | 3/20/2015 2:28:52 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by daniel bibikov Rough in ok cover p/s u/g n ok
|
ELE15-00199
| Electrical Rough-In | 3/20/2015 | 3/20/2015 | 3/20/2015 2:03:35 PM | P | FAIL |
|
|
lock box #0363 Phone #: ###-#### Inspection requested via web by Eric Schroeder 210.52(I)- Foyer walls 3' or longer shall have receptacle outlet installed. Minimum of 13 rooms need to be added to permit. Check branch circuit termination in panel, not complete at rough in
|
ELE13-03274
| Final | 3/20/2015 | 3/20/2015 | 3/20/2015 1:13:40 PM | P | PASS |
|
|
Please call before arriving to ensure access. Thank you Phone #: ###-#### Inspection requested via web by Eric Brown Final ok
|
ELE15-00741
| Conference | 3/20/2015 | 3/20/2015 | 3/20/2015 11:55:54 AM | P | DONE |
|
|
Discussed letting general contractor sheetrock one side of walls. One siding not permitted due to increased time to perform work and inspect.
|
ELE15-00623
| Final | 3/19/2015 | 3/20/2015 | 3/20/2015 11:24:29 AM | A | PASS |
|
|
Can you please call ahead so I can make sure someone is there to let you in. Thank you. Phone #: ###-#### Inspection requested via web by Mark Hennequin Final ok
|
ELE15-00731
| Permanent Service | 3/19/2015 | 3/20/2015 | 3/20/2015 11:14:12 AM | A | FAIL |
|
|
There hasn''t been a meter at this location for over a year, Idaho Power is requiring an inspection of the service before powering. the ACCESS CODE is 9049, Thx Phone #: ###-#### Inspection requested via web by Stephen Kren 110.14- Disimilar metals shall not be in contact. 240.21- Over current protection shall be provided where circuit receives its supply. 250.24(A)(1)- Grounding electrode connection shall be made at any accessible point at service disconnecting means, Unable to verify grounding electrode system. Key would not operate deadbolt.
|
ELE15-00629
| Electrical Rough-In | 3/19/2015 | 3/20/2015 | 3/20/2015 10:19:08 AM | A | FAIL |
|
|
Shane Phone #: ###-#### Corrections not complete. nail plates, support NM above boxes, additional ground rod not installed.
|
ELE15-00270
| Final | 3/20/2015 | 3/20/2015 | 3/20/2015 9:35:08 AM | P | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Emmet Bushman Inspection cancelled from web by: Emmet Bushman
|
ELE14-02838
| Final | 3/20/2015 | 3/20/2015 | 3/20/2015 9:34:56 AM | P | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Emmet Bushman Inspection cancelled from web by: Emmet Bushman
|
ELE15-00714
| Electrical Rough-In | 3/19/2015 | 3/20/2015 | 3/20/2015 9:34:07 AM | A | PASS |
|
|
To cover // Kevin Phone #: ###-#### Underground rough in ok cover
|
GCE15-00041
| GCE-Rough-In Permanent Service | 3/19/2015 | 3/20/2015 | 3/20/2015 8:45:36 AM | A | PASS |
|
|
Darryn ###-#### Rough in ok cover p/s u/g n ok
|